Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

MyNCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1945 1
1946 5
1947 3
1948 2
1949 2
1950 2
1951 5
1952 2
1953 6
1954 5
1955 3
1956 9
1957 6
1958 6
1959 5
1960 9
1961 9
1962 43
1963 211
1964 359
1965 212
1966 110
1967 130
1968 160
1969 96
1970 110
1971 80
1972 90
1973 95
1974 97
1975 114
1976 121
1977 129
1978 103
1979 131
1980 142
1981 125
1982 169
1983 138
1984 178
1985 168
1986 150
1987 185
1988 199
1989 194
1990 209
1991 232
1992 262
1993 291
1994 335
1995 314
1996 337
1997 337
1998 336
1999 293
2000 317
2001 359
2002 401
2003 405
2004 481
2005 502
2006 609
2007 686
2008 703
2009 807
2010 835
2011 886
2012 866
2013 889
2014 977
2015 1021
2016 882
2017 868
2018 885
2019 427
2020 9
Text availability
Article attribute
Article type
Publication date

Search Results

19,161 results
Results by year
Filters applied: . Clear all
Page 1
Computational Modeling of Wound Suture: A Review.
Chanda A, et al. IEEE Rev Biomed Eng 2018 - Review. PMID 29994368
While it is very difficult to translate a surgeon's suturing expertise to an automated environment, computational models could be employed to estimate baseline suture force requirements for a given wound shape, size, and suture material, which could be subsequently processed by a robot. In the literature, there have been few attempts to characterize wound closure and suture mechanics using simple two- and three-dimensional computational models. ...
While it is very difficult to translate a surgeon's suturing expertise to an automated environment, computational models could be employed t …
Suture Coding: A Novel Educational Guide for Suture Patterns.
Gaber M and Abdel-Wahed R. J Surg Educ 2015. PMID 26278657
METHODS: Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. ...Combination between numbers and symbols helps in the understanding of suture techniques easily without complication. There are specific relationships that can be identified between different suture patterns. ...
METHODS: Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. . …
Load to failure of common meniscal repair techniques: effects of suture technique and suture material.
Post WR, et al. Arthroscopy 1997. PMID 9442327
Vertical and horizontal mattress suture techniques were tested using 2-0 Ethibond, and 0-PDS and 1-PDS sutures (Ethicon, Somerville, NJ). ...Selection of suture material had the greatest impact on vertical mattress load to failure and was not important to the strength of the other techniques....
Vertical and horizontal mattress suture techniques were tested using 2-0 Ethibond, and 0-PDS and 1-PDS sutures (Ethicon, Somer …
New suture techniques for best esthetic skin healing.
Gomes OM, et al. Acta Cir Bras 2012. PMID 22760838 Free article.
PURPOSE: To report two new suture techniques for best esthetic skin healing. METHODS: Using the pig skin slices routinely employed for surgical technique training two new types of skin sutures were performed. ...RESULTS: It was confirmed good skin layers union and contention with best esthetic result than observed with the traditional X and intradermal suture techniques. ...
PURPOSE: To report two new suture techniques for best esthetic skin healing. METHODS: Using the pig skin slices routinely empl …
How to choose a suture.
Miyagi K and Matteucci P. Br J Hosp Med (Lond) 2015 - Review. PMID 25761819
Intracorporal knot tying techniques - which is the right one?
Romero P, et al. J Pediatr Surg 2017. PMID 28017412
There were no significant intragroup differences in knot tying performance, task time and accuracy of both suture methods. Students and residents improved in all categories for both ICKT techniques after training. ...This suggests that the two ICKT techniques have similar properties except the quality advantages of the slipping knot. Although students and residents improved in all categories for both ICKT techniques after training, they did not achieve expert level for task times and accuracy. ...
There were no significant intragroup differences in knot tying performance, task time and accuracy of both suture methods. Students a …
The Doubled-Suture Nice Knot.
Boileau P, et al. Orthopedics 2017. PMID 27942736
The authors describe a novel suture fixation technique that combines a doubled suture with a sliding knot. The knot can be tied in both open and arthroscopic surgery to fix torn tendons/ligaments and fractured/osteotomized bones. ...The doubled-suture Nice knot can also be tied over a double-button and has been used for ankle syndesmosis, acromioclavicular joint separation repair, and coracoid bone block fixation. ...
The authors describe a novel suture fixation technique that combines a doubled suture with a sliding knot. The knot can be tie …
[Application of modified purse-string closure in the wound following loop stoma reversal]
Han J, et al. Zhonghua Wei Chang Wai Ke Za Zhi 2018. PMID 30588593 Chinese.
Among them, 43 cases underwent modified purse-string technique (modified purse-string group), 45 cases underwent direct suture (direct suture group). The operation method of modified purse-string suture was as follows: (1) the circumferential subcutaneous adipose tissue was sutured with the absorbable suture, avoiding tightening at knotting and retaining a 1 cm pore;(2)absorbable suture was used to perform purse-string suture of the dermis, retaining a 0.5 cm central pore when knotting; (3) a rubber drain was placed through the pore. ...
Among them, 43 cases underwent modified purse-string technique (modified purse-string group), 45 cases underwent direct suture (direc …
Single-Layer Plication for Repair of Diastasis Recti: The Most Rapid and Efficient Technique
Gama LJM, et al. Aesthet Surg J 2017 - Clinical Trial. PMID 28333252
OBJECTIVES: The aim of this study was to compare the efficacy and time required to repair diastasis recti using different plication techniques. ...Plication of the anterior rectus sheath was performed in two layers with 2-0 monofilament nylon suture (control group) or in a single layer with either a continuous 2-0 monofilament nylon suture (group I) or using a continuous barbed suture (group II). ...
OBJECTIVES: The aim of this study was to compare the efficacy and time required to repair diastasis recti using different plication techn
[Laparoscopic suture and knot techniques].
Pier A, et al. Chirurg 1994 - Review. PMID 8050302 German.
Laparoscopic suture and knot techniques are not yet considered standard laparoscopic procedures. In conventional surgery, it would be unthinkable that a procedure would be attempted without a good working knowledge of suture and knot techniques. ...
Laparoscopic suture and knot techniques are not yet considered standard laparoscopic procedures. In conventional surgery, it w …
19,161 results
Jump to page
Feedback