Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

MyNCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1945 1
1946 5
1947 3
1948 2
1949 2
1950 2
1951 5
1952 2
1953 6
1954 5
1955 3
1956 9
1957 6
1958 6
1959 5
1960 9
1961 13
1962 43
1963 213
1964 365
1965 289
1966 328
1967 430
1968 438
1969 388
1970 478
1971 478
1972 528
1973 611
1974 709
1975 551
1976 453
1977 445
1978 428
1979 498
1980 485
1981 442
1982 523
1983 500
1984 622
1985 656
1986 606
1987 668
1988 647
1989 756
1990 735
1991 749
1992 735
1993 802
1994 845
1995 877
1996 856
1997 928
1998 883
1999 720
2000 821
2001 913
2002 931
2003 999
2004 1114
2005 1184
2006 1258
2007 1434
2008 1563
2009 1740
2010 1811
2011 1714
2012 1699
2013 1674
2014 1755
2015 1692
2016 1514
2017 1421
2018 1390
2019 682
2020 22
Text availability
Article attribute
Article type
Publication date

Search Results

45,961 results
Results by year
Filters applied: . Clear all
Page 1
[Automatic Linear Stapler]
Yoshida Y and Iwasaki A. Kyobu Geka 2018. PMID 30310041 Japanese.
These made simple and uniform suture techniques possible, but it is important to fully understand the usage and characteristics of automatic linear stapler for safe stapling. ...
These made simple and uniform suture techniques possible, but it is important to fully understand the usage and characteristic …
Comparison of 3 suture closure techniques for pelvic flexure enterotomy in equine cadaveric large colon.
Aldrich ED, et al. Vet Surg 2017 - Clinical Trial. PMID 28158935
OBJECTIVE: To compare a 2-layer closure with suture line reversal for a pelvic flexure enterotomy to 1-layer and traditional 2-layer hand sewn closures. ...There was no significant difference in luminal diameter or bursting pressure between the 3 closure techniques. CONCLUSIONS: Two-layer closure with suture line reversal may be an alternative to traditional 2-layer closure for closure of the pelvic flexure based on ex vivo bursting pressure testing and closure time. ...
OBJECTIVE: To compare a 2-layer closure with suture line reversal for a pelvic flexure enterotomy to 1-layer and traditional 2-layer …
Mechanical properties of 6 finger-trap suture techniques.
Earley NF, et al. Vet Surg 2017. PMID 28390057
Constructs made with 3-metric nylon suture and 18-French polyurethane esophagostomy tubing were tested in axial loading to failure. ...CONCLUSION: The mechanical behavior of suture-tube constructs and failure mode is affected by the FTS pattern. Patterns E and F are not advocated due to suture slippage. ...
Constructs made with 3-metric nylon suture and 18-French polyurethane esophagostomy tubing were tested in axial loading to failure. . …
Pectoralis major tendon repair: a biomechanical study of suture button versus transosseous suture techniques.
Thomas W, et al. Knee Surg Sports Traumatol Arthrosc 2015. PMID 24792073
There was a significant difference in yield load, favouring transosseous suture [p = 0.009, suture button (SB) 673.0 N (647.2-691.7 N), transosseous suture (TOS) 855.0 N (750.0-891.4 N)] and median extension, favouring suture button [p = 0.009, SB 8.8 mm (5.0-12.4 mm), TOS 15.2 mm (13.2-17.1 mm)]. 2/3 transosseous suture and 0/3 suture buttons failed before completing 20,000 cycles. ...CONCLUSIONS: Both techniques show advantages. The difference in extension is likely to be more clinically relevant than load tolerated at failure, which is well above physiological levels. ...
There was a significant difference in yield load, favouring transosseous suture [p = 0.009, suture button (SB) 673.0 N (647.2- …
A Systematic Review of Suture Technologies in Total Knee Arthroplasty.
Khlopas A, et al. Surg Technol Int 2019. PMID 30664226
As wound closure technology continues to advance and change, the need to continuously evaluate the current techniques and materials persists. ...Although the cost of an individual barbed suture is potentially higher than the cost of an individual conventional suture, a knotless technique can require a shorter suture length, which might also help decrease costs....
As wound closure technology continues to advance and change, the need to continuously evaluate the current techniques and materials p …
Suture Coding: A Novel Educational Guide for Suture Patterns.
Gaber M and Abdel-Wahed R. J Surg Educ 2015. PMID 26278657
METHODS: Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. ...Combination between numbers and symbols helps in the understanding of suture techniques easily without complication. There are specific relationships that can be identified between different suture patterns. ...
METHODS: Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. . …
Load to failure of common meniscal repair techniques: effects of suture technique and suture material.
Post WR, et al. Arthroscopy 1997. PMID 9442327
Vertical and horizontal mattress suture techniques were tested using 2-0 Ethibond, and 0-PDS and 1-PDS sutures (Ethicon, Somerville, NJ). ...Selection of suture material had the greatest impact on vertical mattress load to failure and was not important to the strength of the other techniques....
Vertical and horizontal mattress suture techniques were tested using 2-0 Ethibond, and 0-PDS and 1-PDS sutures (Ethicon, Somer …
How to choose a suture.
Miyagi K and Matteucci P. Br J Hosp Med (Lond) 2015 - Review. PMID 25761819
Complications of Scleral-Fixated Intraocular Lenses
Davies EC and Pineda R. Semin Ophthalmol 2018 - Review. PMID 28898111
INTRODUCTION: Understanding the evolution of complications after scleral-fixated lens placement demonstrates advantageous surgical techniques and suitable candidates. ...RESULTS: Reviewing complication trends over time, lens tilt and suture erosion have decreased, cystoid macular edema has increased, and retinal detachment has remained the same after scleral-fixated lens placement. ...
INTRODUCTION: Understanding the evolution of complications after scleral-fixated lens placement demonstrates advantageous surgical techni
45,961 results
Jump to page
Feedback