Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

MyNCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1967 2
1979 2
1986 1
1987 3
1988 2
1989 11
1990 27
1991 26
1992 48
1993 61
1994 94
1995 68
1996 94
1997 124
1998 152
1999 219
2000 309
2001 308
2002 399
2003 645
2004 710
2005 974
2006 1098
2007 1141
2008 1308
2009 1466
2010 1557
2011 1766
2012 1845
2013 2087
2014 2330
2015 2705
2016 2658
2017 2638
2018 2843
2019 1517
2020 20
Text availability
Article attribute
Article type
Publication date

Search Results

27,005 results
Results by year
Filters applied: . Clear all
Page 1
Robust radiotherapy planning
Unkelbach J, et al. Phys Med Biol 2018 - Review. PMID 30418942
However, the PTV concept has several limitations, especially in proton therapy. Therefore, robust and probabilistic optimization methods have been developed that directly incorporate motion and uncertainty into treatment plan optimization for intensity modulated radiotherapy (IMRT) and intensity modulated proton therapy (IMPT). ...Over the past ten years, IMPT has emerged as a new application for robust planning methods. In proton therapy, range or setup errors may lead to dose degradation and misalignment of dose contributions from different beams - a problem that cannot generally be addressed by margins. ...
However, the PTV concept has several limitations, especially in proton therapy. Therefore, robust and probabilistic optimization m
Automation in intensity modulated radiotherapy treatment planning-a review of recent innovations
Hussein M, et al. Br J Radiol 2018 - Review. PMID 30074813 Free PMC article.
Radiotherapy treatment planning of complex radiotherapy techniques, such as intensity modulated radiotherapy and volumetric modulated arc therapy, is a resource-intensive process requiring a high level of treatment planner intervention to ensure high plan quality. ...
Radiotherapy treatment planning of complex radiotherapy techniques, such as intensity modulated radiotherapy and volumetric modulated arc …
Performance Comparison of Knowledge-Based Dose Prediction Techniques Based on Limited Patient Data
Landers A, et al. Technol Cancer Res Treat 2018. PMID 30411666 Free PMC article.
We compare the dose prediction accuracy of 3 prediction methods including statistical voxel dose learning, spectral regression, and support vector regression based on limited patient training data. METHODS: Statistical voxel dose learning, spectral regression, and support vector regression were used to predict the dose of noncoplanar intensity-modulated radiation therapy (4π) and volumetric-modulated arc therapy head and neck, 4π lung, and volumetric-modulated arc therapy prostate plans. ...
We compare the dose prediction accuracy of 3 prediction methods including statistical voxel dose learning, spectral regression, and s …
Recent developments in non-coplanar radiotherapy
Smyth G, et al. Br J Radiol 2019 - Review. PMID 30694086 Free PMC article.
This paper gives an overview of recent developments in non-coplanar intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). ...Novel techniques developed for C-arm and non-standard linac geometries, methods of optimization, and clinical applications are reviewed. ...
This paper gives an overview of recent developments in non-coplanar intensity modulated radiotherapy (IMRT) and volumetric modulated arc …
Threshold-driven optimization for reference-based auto-planning
Long T, et al. Phys Med Biol 2018. PMID 29328050
A threshold-focused objective tuning should be explored over conventional methods of updating preference weights for DVH-guided treatment planning....
A threshold-focused objective tuning should be explored over conventional methods of updating preference weights for DVH-guided treat …
A quantitative measure for radiation treatment plan quality
Laura Licon A, et al. J BUON 2018. PMID 30570873 Free article.
PURPOSE: To develop and validate an intensity modulated radiation therapy (IMRT) treatment plan quantitative score using QUANTEC dose/volume parameters to assess plan quality. METHODS: 132 IMRT and volumetric modulated Arc therapy (VMAT) patient plans of various treatment sites were evaluated. The optimized plan's dose volume histogram (DVH) was exported to Velocity for evaluation. ...
PURPOSE: To develop and validate an intensity modulated radiation therapy (IMRT) treatment plan quantitative score using QUANTEC dose …
Motion induced interplay effects for VMAT radiotherapy
Edvardsson A, et al. Phys Med Biol 2018. PMID 29671410
The purpose of this study was to develop a method to simulate breathing motion induced interplay effects for volumetric modulated arc therapy (VMAT), to verify the proposed method with measurements, and to use the method to investigate how interplay effects vary with different patient- and machine specific parameters. ...
The purpose of this study was to develop a method to simulate breathing motion induced interplay effects for volumetric modulated arc the
27,005 results
Jump to page
Feedback