Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1988 1
1989 1
1993 3
1996 1
1998 2
1999 1
2000 7
2001 3
2002 2
2003 9
2004 14
2005 20
2006 22
2007 48
2008 46
2009 57
2010 58
2011 101
2012 104
2013 93
2014 136
2015 130
2016 167
2017 173
2018 175
2019 162
2020 168
2021 76
Text availability
Article attribute
Article type
Publication date

Search Results

1,491 results
Results by year
Filters applied: . Clear all
Page 1
WITHDRAWN: 3D-printed RF probeheads for low-cost, high-throughput NMR.
Horch RA, Gore JC. Horch RA, et al. Magn Reson Imaging. 2017 Jan 13:S0730-725X(17)30004-8. doi: 10.1016/j.mri.2017.01.005. Online ahead of print. Magn Reson Imaging. 2017. PMID: 28089938
This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. ...
This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this ma …
Translating preclinical MRI methods to clinical oncology.
Hormuth DA 2nd, Sorace AG, Virostko J, Abramson RG, Bhujwalla ZM, Enriquez-Navas P, Gillies R, Hazle JD, Mason RP, Quarles CC, Weis JA, Whisenant JG, Xu J, Yankeelov TE. Hormuth DA 2nd, et al. J Magn Reson Imaging. 2019 Nov;50(5):1377-1392. doi: 10.1002/jmri.26731. Epub 2019 Mar 29. J Magn Reson Imaging. 2019. PMID: 30925001 Free PMC article. Review.
The complexity of modern in vivo magnetic resonance imaging (MRI) methods in oncology has dramatically changed in the last 10 years. ...Level of Evidence: 5 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2019;50:1377-1392....
The complexity of modern in vivo magnetic resonance imaging (MRI) methods in oncology has dramatically changed in the last 10 years. …
Synthesized b0 for diffusion distortion correction (Synb0-DisCo).
Schilling KG, Blaber J, Huo Y, Newton A, Hansen C, Nath V, Shafer AT, Williams O, Resnick SM, Rogers B, Anderson AW, Landman BA. Schilling KG, et al. Magn Reson Imaging. 2019 Dec;64:62-70. doi: 10.1016/j.mri.2019.05.008. Epub 2019 May 7. Magn Reson Imaging. 2019. PMID: 31075422 Free PMC article.
In this study, we aim to enable TOPUP-like processing with historical and/or limited diffusion imaging data that include only a structural image and single blip diffusion image. ...We evaluate the efficacy of this approach (named Synb0-DisCo) and show that our disto …
In this study, we aim to enable TOPUP-like processing with historical and/or limited diffusion imaging data that include only a struc …
Probing axons using multi-compartmental diffusion in multiple sclerosis.
Bagnato F, Franco G, Li H, Kaden E, Ye F, Fan R, Chen A, Alexander DC, Smith SA, Dortch R, Xu J. Bagnato F, et al. Ann Clin Transl Neurol. 2019 Sep;6(9):1595-1605. doi: 10.1002/acn3.50836. Epub 2019 Aug 13. Ann Clin Transl Neurol. 2019. PMID: 31407532 Free PMC article.
OBJECTS: The diffusion-based spherical mean technique (SMT) provides a novel model to relate multi-b-value diffusion magnetic resonance imaging (MRI) data to features of tissue microstructure. ...Inverse correlations were seen between V(ax) and …
OBJECTS: The diffusion-based spherical mean technique (SMT) provides a novel model to relate multi-b-value diffusion ma …
Inferring brain tissue composition and microstructure via MR relaxometry.
Does MD. Does MD. Neuroimage. 2018 Nov 15;182:136-148. doi: 10.1016/j.neuroimage.2017.12.087. Epub 2018 Jan 2. Neuroimage. 2018. PMID: 29305163 Free PMC article. Review.
MRI relaxometry is sensitive to a variety of tissue characteristics in a complex manner, which makes it both attractive and challenging for characterizing tissue. This article reviews the most common water proton relaxometry measures, T(1), T(2), and T
MRI relaxometry is sensitive to a variety of tissue characteristics in a complex manner, which makes it both attractive and challengi
Hepatobiliary imaging.
Liu PS, Abramson RG. Liu PS, et al. Magn Reson Imaging Clin N Am. 2014 Aug;22(3):xv-xvi. doi: 10.1016/j.mric.2014.05.003. Magn Reson Imaging Clin N Am. 2014. PMID: 25086942 No abstract available.
MRI-cytometry: Mapping nonparametric cell size distributions using diffusion MRI.
Xu J, Jiang X, Devan SP, Arlinghaus LR, McKinley ET, Xie J, Zu Z, Wang Q, Chakravarthy AB, Wang Y, Gore JC. Xu J, et al. Magn Reson Med. 2021 Feb;85(2):748-761. doi: 10.1002/mrm.28454. Epub 2020 Sep 16. Magn Reson Med. 2021. PMID: 32936478
PURPOSE: This report introduces and validates a new diffusion MRI-based method, termed MRI-cytometry, which can noninvasively map intravoxel, nonparametric cell size distributions in tissues. METHODS: MRI was used to acquire diffusion MRI
PURPOSE: This report introduces and validates a new diffusion MRI-based method, termed MRI-cytometry, which can noninva …
A simple estimate of axon size with diffusion MRI.
Harkins KD, Beaulieu C, Xu J, Gore JC, Does MD. Harkins KD, et al. Neuroimage. 2021 Feb 15;227:117619. doi: 10.1016/j.neuroimage.2020.117619. Epub 2020 Dec 8. Neuroimage. 2021. PMID: 33301942 Free PMC article.
Noninvasive estimation of mean axon diameter presents a new opportunity to explore white matter plasticity, development, and pathology. Several diffusion-weighted MRI (DW-MRI) methods have been proposed to measure the average axon diameter in white matter, bu …
Noninvasive estimation of mean axon diameter presents a new opportunity to explore white matter plasticity, development, and pathology. Seve …
Harmonizing 1.5T/3T Diffusion Weighted MRI through Development of Deep Learning Stabilized Microarchitecture Estimators.
Nath V, Remedios S, Parvathaneni P, Hansen CB, Bayrak RG, Bermudez C, Blaber JA, Schilling KG, Janve VA, Gao Y, Huo Y, Lyu I, Williams O, Resnick S, Beason-Held L, Rogers BP, Stepniewska I, Anderson AW, Landman BA. Nath V, et al. Proc SPIE Int Soc Opt Eng. 2019 Feb;10949:10.1117/12.2512902. doi: 10.1117/12.2512902. Epub 2019 Mar 15. Proc SPIE Int Soc Opt Eng. 2019. PMID: 32089583 Free PMC article.
Diffusion weighted magnetic resonance imaging (DW-MRI) is interpreted as a quantitative method that is sensitive to tissue microarchitecture at a millimeter scale. However, the sensitization is dependent on acquisition sequences (e.g., diffusion time,
Diffusion weighted magnetic resonance imaging (DW-MRI) is interpreted as a quantitative method that is sensitive to tissue mic
Rapid quantitative imaging of high intensity ultrasonic pressure fields.
Luo H, Kusunose J, Pinton G, Caskey CF, Grissom WA. Luo H, et al. J Acoust Soc Am. 2020 Aug;148(2):660. doi: 10.1121/10.0001689. J Acoust Soc Am. 2020. PMID: 32873034 Free PMC article.
Results at two frequencies and comparisons to hydrophone measurements show that CW-BOS imaging produces high-resolution quantitative RMS projected FUS pressure maps in under 10 s, the technique is linear and robust to beam rotations and translations, and it can map aberrat …
Results at two frequencies and comparisons to hydrophone measurements show that CW-BOS imaging produces high-resolution quantitative RMS pro …
1,491 results
You have reached the last page of results. A maximum of 10,000 results are available.
Jump to page