Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Edit custom filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1970 1
1973 1
1974 2
1975 5
1976 3
1977 1
1978 1
1980 1
1981 1
1982 3
1985 3
1986 1
1987 1
1988 2
1989 2
1990 5
1991 3
1992 1
1993 3
1994 3
1996 4
1997 2
1998 1
1999 1
2000 2
2001 2
2003 3
2004 6
2005 4
2006 7
2007 7
2008 7
2009 16
2010 16
2011 20
2012 17
2013 20
2014 8
2015 19
2016 15
2017 6
2018 9
2019 3
2020 5
2021 10
2022 8
2023 3
2024 5
2025 5
2026 2

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

248 results

Results by year

Filters applied: . Clear all
Page 1
Assessment of fluid responsiveness using pulse pressure variation, stroke volume variation, plethysmographic variability index, central venous pressure, and inferior vena cava variation in patients undergoing mechanical ventilation: a systematic review and meta-analysis.
Chaves RCF, Barbas CSV, Queiroz VNF, Serpa Neto A, Deliberato RO, Pereira AJ, Timenetsky KT, Silva Júnior JM, Takaoka F, de Backer D, Celi LA, Corrêa TD. Chaves RCF, et al. Crit Care. 2024 Aug 31;28(1):289. doi: 10.1186/s13054-024-05078-9. Crit Care. 2024. PMID: 39217370 Free PMC article.
IMPORTANCE: Maneuvers assessing fluid responsiveness before an intravascular volume expansion may limit useless fluid administration, which in turn may improve outcomes. ...RESULTS: A total of 69 studies, encompassing 3185 fluid challenges and 2711 pat …
IMPORTANCE: Maneuvers assessing fluid responsiveness before an intravascular volume expansion may limit useless fluid a …
Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense.
Marik PE, Cavallazzi R. Marik PE, et al. Crit Care Med. 2013 Jul;41(7):1774-81. doi: 10.1097/CCM.0b013e31828a25fd. Crit Care Med. 2013. PMID: 23774337
AIM: To perform an updated meta-analysis incorporating recent studies that investigated indices predictive of fluid responsiveness. A priori subgroup analysis was planned according to the location where the study was performed (ICU or operating room). ...CONCLUSIONS …
AIM: To perform an updated meta-analysis incorporating recent studies that investigated indices predictive of fluid responsiveness
Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares.
Marik PE, Baram M, Vahid B. Marik PE, et al. Chest. 2008 Jul;134(1):172-8. doi: 10.1378/chest.07-2331. Chest. 2008. PMID: 18628220
OBJECTIVE: A systematic review of the literature to determine the following: (1) the relationship between CVP and blood volume, (2) the ability of CVP to predict fluid responsiveness, and (3) the ability of the change in CVP (DeltaCVP) to predict fluid res
OBJECTIVE: A systematic review of the literature to determine the following: (1) the relationship between CVP and blood volume, (2) the abil …
Measurement and interpretation of central venous pressure: a narrative review.
Lloyd-Donald P, Fujino M, Waldman B, Miles LF. Lloyd-Donald P, et al. Anaesthesia. 2025 Sep;80(9):1093-1102. doi: 10.1111/anae.16633. Epub 2025 Jun 3. Anaesthesia. 2025. PMID: 40457939 Free PMC article. Review.
While central venous pressure has been used traditionally to assess intravascular volume status and fluid responsiveness, mounting evidence suggests that its absolute value alone is an unreliable predictor of such states. ...Central venous pressure in isolation is c …
While central venous pressure has been used traditionally to assess intravascular volume status and fluid responsiveness, moun …
Central venous pressure monitoring in critical care settings.
Hill B, Smith C. Hill B, et al. Br J Nurs. 2021 Feb 25;30(4):230-236. doi: 10.12968/bjon.2021.30.4.230. Br J Nurs. 2021. PMID: 33641398
Central venous pressure (CVP) is the most frequently used measure to guide fluid resuscitation in critically ill patients. It is most often done via a central venous catheter (CVC) positioned in the right atrium or superior or inferior vena cava as close to the right atriu …
Central venous pressure (CVP) is the most frequently used measure to guide fluid resuscitation in critically ill patients. It is most …
Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions.
De Backer D, Vincent JL. De Backer D, et al. Crit Care. 2018 Feb 23;22(1):43. doi: 10.1186/s13054-018-1959-3. Crit Care. 2018. PMID: 29471884 Free PMC article.
The central venous pressure (CVP) is the most frequently used variable to guide fluid resuscitation in critically ill patients, although its use has been challenged. In this viewpoint, we use a question and answer format to highlight the potential advantages and limitation …
The central venous pressure (CVP) is the most frequently used variable to guide fluid resuscitation in critically ill patients, altho …
Demystifying Volume Status: An Ultrasound-Guided Physiologic Framework.
Kan JY, Arishenkoff S, Wiskar K. Kan JY, et al. Chest. 2025 Jun;167(6):1667-1683. doi: 10.1016/j.chest.2024.12.026. Epub 2025 Jan 7. Chest. 2025. PMID: 39788317 Free PMC article. Review.
TOPIC IMPORTANCE: Accurate assessment of a patient's volume status is crucial in many conditions, informing decisions on fluid prescribing, vasoactive agents, and decongestive therapies. Determining a patient's volume status is challenging because of limitations in examina …
TOPIC IMPORTANCE: Accurate assessment of a patient's volume status is crucial in many conditions, informing decisions on fluid prescr …
Variations of pulse pressure and central venous pressure may predict fluid responsiveness in mechanically ventilated patients during lung recruitment manoeuvre: an ancillary study.
Desebbe O, Mondor W, Gergele L, Raphael D, Vallier S. Desebbe O, et al. BMC Anesthesiol. 2022 Aug 23;22(1):269. doi: 10.1186/s12871-022-01815-1. BMC Anesthesiol. 2022. PMID: 35999508 Free PMC article.
Using a maximum of 30 cmH(2)O inspiratory pressure during the LRM, deltaCVP and deltaPP had a threshold value to predict fluid responsiveness of 2 mmHg and 4 mmHg, with sensitivities of 89% and 89% and specificities of 67% and 89%, respectively. ...CONCLUSIONS: A st …
Using a maximum of 30 cmH(2)O inspiratory pressure during the LRM, deltaCVP and deltaPP had a threshold value to predict fluid res
Crystalloids vs. colloids for fluid resuscitation in the Intensive Care Unit: A systematic review and meta-analysis.
Martin GS, Bassett P. Martin GS, et al. J Crit Care. 2019 Apr;50:144-154. doi: 10.1016/j.jcrc.2018.11.031. Epub 2018 Nov 30. J Crit Care. 2019. PMID: 30540968 Free article.
PURPOSE: Guidelines recommend crystalloids for fluid resuscitation in sepsis/shock and switching to albumin in cases where crystalloids are insufficient. We evaluated hemodynamic response to crystalloids/colloids in critically ill adults. MATERIALS AND METHODS: The …
PURPOSE: Guidelines recommend crystalloids for fluid resuscitation in sepsis/shock and switching to albumin in cases where crystalloi …
248 results