Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1984 1
1987 1
1993 1
1994 1
1999 2
2001 1
2002 2
2003 2
2004 1
2005 1
2006 1
2007 2
2008 1
2009 1
2011 2
2012 2
2013 2
2014 2
2015 1
2016 3
2017 2
2018 3
2019 4
2022 3
2023 0
Text availability
Article attribute
Article type
Publication date

Search Results

38 results
Results by year
Filters applied: . Clear all The following terms were ignored: %, %, %, %, % The following terms were not found in PubMed: 22Hon, 5BAuthor
Page 1
Perceptual impact of astigmatism induction in presbyopes.
Benedi-Garcia C, Velasco-Ocana M, Dorronsoro C, Pascual D, Hernandez M, Marin G, Marcos S. Benedi-Garcia C, et al. Vision Res. 2019 Dec;165:143-151. doi: 10.1016/j.visres.2019.10.008. Epub 2019 Nov 18. Vision Res. 2019. PMID: 31751899 Free article.
Measurements were performed using a custom-developed Adaptive Optics system, which allowed correction of high order aberrations and induction of astigmatism (0.5, 1, 1.5 and 2.0 D; axis: 180, 45 and 22.5). Upon induction of astigmatism, best focus shifted towards negative …
Measurements were performed using a custom-developed Adaptive Optics system, which allowed correction of high order aberrations and inductio …
Mass spectrometry imaging of biomarker lipids for phagocytosis and signalling during focal cerebral ischaemia.
Nielsen MM, Lambertsen KL, Clausen BH, Meyer M, Bhandari DR, Larsen ST, Poulsen SS, Spengler B, Janfelt C, Hansen HS. Nielsen MM, et al. Sci Rep. 2016 Dec 22;6:39571. doi: 10.1038/srep39571. Sci Rep. 2016. PMID: 28004822 Free PMC article.
Mass spectrometry imaging (desorption electrospray ionization and matrix assisted laser desorption ionization) was applied on brain sections from mice 2 h, 24 h, 5d, 7d, and 20d after permanent focal cerebral ischaemia. Within 24 h, N-acyl-phosphatidylethanolamines, …
Mass spectrometry imaging (desorption electrospray ionization and matrix assisted laser desorption ionization) was applied on brain sections …
A novel minimally invasive percutaneous treatment for Essex-Lopresti joint depression-type DIACFs by ligamentotaxis.
Chen Z, Fan C, Zhang J, Zhao C, Du X, Huang W, Ni W, Luo G. Chen Z, et al. BMC Surg. 2022 Dec 16;22(1):431. doi: 10.1186/s12893-022-01868-6. BMC Surg. 2022. PMID: 36527011 Free PMC article.
RESULTS: Thirty-nine patients with Essex-Lopresti joint depression type DIACFs were finally included. According to the Sanders classification, 22 were type II, 12 were type III and 5 were type IV. The preoperative waiting time and the hospital stay of Group A were 3.7 1.6 …
RESULTS: Thirty-nine patients with Essex-Lopresti joint depression type DIACFs were finally included. According to the Sanders classificatio …
Noncontact common-path Fourier domain optical coherence tomography method for in vitro intraocular lens power measurement.
Huang Y, Zhang K, Kang JU, Calogero D, James RH, Ilev IK. Huang Y, et al. J Biomed Opt. 2011 Dec;16(12):126005. doi: 10.1117/1.3660313. J Biomed Opt. 2011. PMID: 22191922 Free article.
The CP-FD-OCT design provides high accuracy of IOL surface reconstruction. The axial position detection accuracy is calibrated at 1.22 mum in balanced saline solution used for simulation of in situ conditions. The lateral sampling rate is controlled by the step size of lin …
The CP-FD-OCT design provides high accuracy of IOL surface reconstruction. The axial position detection accuracy is calibrated at 1.22
Visual outcomes of a new nondiffractive extended depth-of-focus intraocular lens targeted for minimonovision: 3-month results of a prospective cohort study.
van Amelsfort T, Webers VSC, Bauer NJC, Clement LHH, van den Biggelaar FJHM, Nuijts RMMA. van Amelsfort T, et al. J Cataract Refract Surg. 2022 Feb 1;48(2):151-156. doi: 10.1097/j.jcrs.0000000000000825. J Cataract Refract Surg. 2022. PMID: 34653091
Outcome measures were the uncorrected distance visual acuity (UDVA), corrected distance visual acuity, uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), distance corrected intermediate visual acuity, distance corrected near visual acuity, refra …
Outcome measures were the uncorrected distance visual acuity (UDVA), corrected distance visual acuity, uncorrected intermediate visual acuit …
[Phototherapeutic keratectomy (PTK) after epidemic keratoconjunctivitis].
Quentin CD, Tondrow M, Vogel M. Quentin CD, et al. Ophthalmologe. 1999 Feb;96(2):92-6. doi: 10.1007/s003470050381. Ophthalmologe. 1999. PMID: 10095355 German.
Preoperatively, the visual acuity was 0.1-0.9 (mean: 0.39 +/- 0.22) and the brightness acuity test (BAT) was 0.05-0.5 (mean: 0.25 +/- 0.15). ...
Preoperatively, the visual acuity was 0.1-0.9 (mean: 0.39 +/- 0.22) and the brightness acuity test (BAT) was 0.05-0.5 (mean: 0.25 +/- …
The prevalence of anisometropia in population base study.
Ostadimoghaddam H, Fotouhi A, Hashemi H, Yekta AA, Heravian J, Hemmati B, Jafarzadehpur E, Rezvan F, Khabazkhoob M. Ostadimoghaddam H, et al. Strabismus. 2012 Dec;20(4):152-7. doi: 10.3109/09273972.2012.680229. Strabismus. 2012. PMID: 23211139
38 results