Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2012 2
2013 2
2014 3
2015 8
2016 7
2017 6
2018 5
2019 7
2020 5
2021 2
2022 2
2023 0
Text availability
Article attribute
Article type
Publication date

Search Results

41 results
Results by year
Filters applied: . Clear all
Page 1
Assessment of Molecular Acoustic Angiography for Combined Microvascular and Molecular Imaging in Preclinical Tumor Models.
Lindsey BD, Shelton SE, Foster FS, Dayton PA. Lindsey BD, et al. Among authors: dayton pa. Mol Imaging Biol. 2017 Apr;19(2):194-202. doi: 10.1007/s11307-016-0991-4. Mol Imaging Biol. 2017. PMID: 27519522 Free PMC article.
RESULTS: Although resulting differences in image intensity due to varying microbubble dose were not significant between the two lowest doses, superharmonic imaging had significantly higher contrast-to-tissue ratio (CTR) than multi-pulse imaging (mean across all doses 13.98 dB for …
RESULTS: Although resulting differences in image intensity due to varying microbubble dose were not significant between the two lowest doses …
First-in-Human Study of Acoustic Angiography in the Breast and Peripheral Vasculature.
Shelton SE, Lindsey BD, Dayton PA, Lee YZ. Shelton SE, et al. Among authors: dayton pa. Ultrasound Med Biol. 2017 Dec;43(12):2939-2946. doi: 10.1016/j.ultrasmedbio.2017.08.1881. Epub 2017 Oct 2. Ultrasound Med Biol. 2017. PMID: 28982628 Free PMC article.
In this clinical note, we describe the translation of a contrast-enhanced ultrasound technique, acoustic angiography, to human imaging. We illustrate the feasibility of this technique with initial studies in imaging the hand, wrist and breast using Definity microbub …
In this clinical note, we describe the translation of a contrast-enhanced ultrasound technique, acoustic angiography, to human …
Implementation of a Novel 288-Element Dual-Frequency Array for Acoustic Angiography: In Vitro and In Vivo Characterization.
Newsome IG, Kierski TM, Pang G, Yin J, Yang J, Cherin E, Foster FS, Carnevale CA, Demore CEM, Dayton PA. Newsome IG, et al. Among authors: dayton pa. IEEE Trans Ultrason Ferroelectr Freq Control. 2021 Aug;68(8):2657-2666. doi: 10.1109/TUFFC.2021.3074025. Epub 2021 Jul 26. IEEE Trans Ultrason Ferroelectr Freq Control. 2021. PMID: 33872146 Free PMC article.
Acoustic angiography is a superharmonic contrast-enhanced ultrasound imaging method that produces high-resolution, 3-D maps of the microvasculature. ...In this work, we present a system for performing acoustic angiography with a novel dual-frequency(DF
Acoustic angiography is a superharmonic contrast-enhanced ultrasound imaging method that produces high-resolution, 3-D maps of
Acoustic Angiography: Superharmonic Contrast-Enhanced Ultrasound Imaging for Noninvasive Visualization of Microvasculature.
Newsome IG, Dayton PA. Newsome IG, et al. Among authors: dayton pa. Methods Mol Biol. 2022;2393:641-655. doi: 10.1007/978-1-0716-1803-5_34. Methods Mol Biol. 2022. PMID: 34837204
Acoustic angiography is a contrast-enhanced ultrasound technique that relies on superharmonic imaging to form high-resolution, three-dimensional maps of the microvasculature. In order to obtain signal separation between tissue and contrast, acoustic angiog
Acoustic angiography is a contrast-enhanced ultrasound technique that relies on superharmonic imaging to form high-resolution,
An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography.
Mahmud MM, Wu X, Sanders JL, Biliroglu AO, Adelegan OJ, Newsome IG, Yamaner FY, Dayton PA, Oralkan O. Mahmud MM, et al. Among authors: dayton pa. IEEE Trans Ultrason Ferroelectr Freq Control. 2020 Nov;67(11):2291-2302. doi: 10.1109/TUFFC.2020.3001221. Epub 2020 Jun 9. IEEE Trans Ultrason Ferroelectr Freq Control. 2020. PMID: 32746179 Free PMC article.
This study demonstrates, in detail, the potential of using capacitive micromachined ultrasonic transducers (CMUTs) for acoustic angiography of the microvasculature. It is known that when ultrasound contrast agents (microbubbles) are excited with moderate acoustic
This study demonstrates, in detail, the potential of using capacitive micromachined ultrasonic transducers (CMUTs) for acoustic an
On the Relationship between Dynamic Contrast-Enhanced Ultrasound Parameters and the Underlying Vascular Architecture Extracted from Acoustic Angiography.
Panfilova A, Shelton SE, Caresio C, van Sloun RJG, Molinari F, Wijkstra H, Dayton PA, Mischi M. Panfilova A, et al. Among authors: dayton pa. Ultrasound Med Biol. 2019 Feb;45(2):539-548. doi: 10.1016/j.ultrasmedbio.2018.08.018. Epub 2018 Nov 30. Ultrasound Med Biol. 2019. PMID: 30509785 Free PMC article.
This work was aimed at identifying which vascular features are reflected by the estimated perfusion and dispersion parameters through comparison with acoustic angiography (AA). AA is a high-resolution technique that allows quantification of vascular morphology. ...
This work was aimed at identifying which vascular features are reflected by the estimated perfusion and dispersion parameters through compar …
Visualization of Microvascular Angiogenesis Using Dual-Frequency Contrast-Enhanced Acoustic Angiography: A Review.
Newsome IG, Dayton PA. Newsome IG, et al. Among authors: dayton pa. Ultrasound Med Biol. 2020 Oct;46(10):2625-2635. doi: 10.1016/j.ultrasmedbio.2020.06.009. Epub 2020 Jul 20. Ultrasound Med Biol. 2020. PMID: 32703659 Free PMC article. Review.
To date, acoustic angiography has been performed with dual-element transducers that can achieve high contrast-to-tissue ratio and resolution in pre-clinical small animal models. In this review, we first describe the development of acoustic angiography, …
To date, acoustic angiography has been performed with dual-element transducers that can achieve high contrast-to-tissue ratio …
41 results