Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Edit custom filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1975 2
1976 1
1978 1
1981 1
1982 2
1984 2
1985 1
1986 1
1987 2
1988 1
1989 2
1990 1
1991 1
1992 2
1993 2
1994 2
1995 3
1996 3
1997 1
1998 2
1999 2
2001 3
2002 2
2003 1
2004 4
2005 2
2006 1
2007 3
2008 1
2009 6
2010 3
2011 3
2012 6
2013 3
2014 5
2015 7
2016 4
2017 3
2018 9
2019 7
2020 1
2021 6
2023 5
2024 7
2025 6
2026 0

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

121 results

Results by year

Filters applied: . Clear all
Page 1
Brain stimulation targets for chronic pain: Insights from meta-analysis, functional connectivity and literature review.
Kong Q, Li T, Reddy S, Hodges S, Kong J. Kong Q, et al. Neurotherapeutics. 2024 Jan;21(1):e00297. doi: 10.1016/j.neurot.2023.10.007. Epub 2023 Dec 19. Neurotherapeutics. 2024. PMID: 38237403 Free PMC article. Review.
Our results showed that the primary motor cortex (M1) (C3/C4, 10-20 EEG system) and prefrontal cortex (F3/F4/Fz) were the most used brain stimulation targets for chronic pain treatment according to the literature review. ...The derived coordinates (with integ …
Our results showed that the primary motor cortex (M1) (C3/C4, 10-20 EEG system) and prefrontal cortex (F3/F4/Fz) were t …
Electrodes.
Morris HH 3rd, Lüders H. Morris HH 3rd, et al. Electroencephalogr Clin Neurophysiol Suppl. 1985;37:3-26. Electroencephalogr Clin Neurophysiol Suppl. 1985. PMID: 3859406
The international 10/20 system of electrode placement, the T1,T2 electrodes and other more closely placed electrodes record activity generated mainly from the brain convexities. Nasopharyngeal, ethmoidal, and sphenoidal electrodes
The international 10/20 system of electrode placement, the T1,T2 electrodes and other more closely placed …
Sensitivity of scalp 10-20 EEG and magnetoencephalography.
Kakisaka Y, Alkawadri R, Wang ZI, Enatsu R, Mosher JC, Dubarry AS, Alexopoulos AV, Burgess RC. Kakisaka Y, et al. Epileptic Disord. 2013 Mar;15(1):27-31. doi: 10.1684/epd.2013.0554. Epileptic Disord. 2013. PMID: 23531601 Free PMC article.
Two MEG recordings were performed for both patients, each recorded simultaneously with initially scalp EEG, based on international 10-20 electrode placement with additional electrodes for anterior temporal regions, and subsequently stereo …
Two MEG recordings were performed for both patients, each recorded simultaneously with initially scalp EEG, based on international …
Electroencephalography: electrode arrays in dogs.
Everest S, Gaitero L, Dony R, Linden AZ, Cortez MA, James FMK. Everest S, et al. Front Vet Sci. 2024 Nov 14;11:1402546. doi: 10.3389/fvets.2024.1402546. eCollection 2024. Front Vet Sci. 2024. PMID: 39611111 Free PMC article. Review.
Electroencephalography (EEG) is the gold standard for confirming epileptic seizures in both human and veterinary patients. ...A recent survey study confirmed that a variety of canine EEG protocols are concurrently in use, including diverse electrode ar
Electroencephalography (EEG) is the gold standard for confirming epileptic seizures in both human and veterinary patients. ...
Adequacy of the International 10-20 electrode system for computed neurophysiologic topography.
Myslobodsky MS, Coppola R, Bar-Ziv J, Weinberger DR. Myslobodsky MS, et al. J Clin Neurophysiol. 1990 Oct;7(4):507-18. doi: 10.1097/00004691-199010000-00006. J Clin Neurophysiol. 1990. PMID: 2262544 Review.
The adequacy of the International 10-20 System is reviewed in light of demands imposed on the accuracy of lead placement by improvements in spatiotemporal brain electrical activity mapping technology. ...Therefore, the authors suggest that practitioners who e …
The adequacy of the International 10-20 System is reviewed in light of demands imposed on the accuracy of lead placement
Using the international 10-20 EEG system for positioning of transcranial magnetic stimulation.
Herwig U, Satrapi P, Schönfeldt-Lecuona C. Herwig U, et al. Brain Topogr. 2003 Winter;16(2):95-9. doi: 10.1023/b:brat.0000006333.93597.9d. Brain Topogr. 2003. PMID: 14977202
BACKGROUND: The International 10-20 system for EEG electrode placement is increasingly applied for the positioning of transcranial magnetic stimulation (TMS) in cognitive neuroscience and in psychiatric treatment studies. ...METHODS: In 21 subje …
BACKGROUND: The International 10-20 system for EEG electrode placement is increasingly applied for the po …
Determining Electrode Placement for Transcranial Direct Current Stimulation: A Comparison of EEG- Versus TMS-Guided Methods.
Rich TL, Menk JS, Rudser KD, Chen M, Meekins GD, Peña E, Feyma T, Bawroski K, Bush C, Gillick BT. Rich TL, et al. Clin EEG Neurosci. 2017 Nov;48(6):367-375. doi: 10.1177/1550059417709177. Epub 2017 May 22. Clin EEG Neurosci. 2017. PMID: 28530154 Free PMC article.
The optimal method for the primary motor cortex (M1) somatotopic localization for tDCS electrode placement has not been established. The objective, therefore, was to determine the location of the M1 derived using the 10/20 electroencephalography
The optimal method for the primary motor cortex (M1) somatotopic localization for tDCS electrode placement has not been establ …
A Preliminary Study on Precision Image Guidance for Electrode Placement in an EEG Study.
Jeon S, Chien J, Song C, Hong J. Jeon S, et al. Brain Topogr. 2018 Mar;31(2):174-185. doi: 10.1007/s10548-017-0610-y. Epub 2017 Dec 4. Brain Topogr. 2018. PMID: 29204789
To address the variation issue, we propose an image guidance system for precision electrode placement. Following the electrode placement according to the 10/20 system, affixed electrodes are laser-scanned together with the facial s …
To address the variation issue, we propose an image guidance system for precision electrode placement. Following the electr
Cerebral location of international 10-20 system electrode placement.
Homan RW, Herman J, Purdy P. Homan RW, et al. Electroencephalogr Clin Neurophysiol. 1987 Apr;66(4):376-82. doi: 10.1016/0013-4694(87)90206-9. Electroencephalogr Clin Neurophysiol. 1987. PMID: 2435517
We employed CT scanning to correlate scalp markers placed according to the international 10-20 system with underlying cerebral structures. Subjects were 12 normal volunteers. ...Variability of cortical electrode location was substantial in some cases and not …
We employed CT scanning to correlate scalp markers placed according to the international 10-20 system with underlying cerebral …
Anatomically Veridical On-Scalp Sensor Topographies.
Alexander NA, Medrano J, Seymour RA, Mellor S, O'Neill GC, Spedden ME, Tierney TM, Maguire EA. Alexander NA, et al. Eur J Neurosci. 2025 Mar;61(5):e70060. doi: 10.1111/ejn.70060. Eur J Neurosci. 2025. PMID: 40083072 Free PMC article.
Positioning of sensors relative to anatomy, as in the classic 10-20 system of EEG electrode placement, enables the use of 2D topographies that are familiar to many researchers and clinicians. ...To address this problem, we adapted and extended t …
Positioning of sensors relative to anatomy, as in the classic 10-20 system of EEG electrode placement, en …
121 results