Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2013 1
2014 4
2015 3
2016 3
2017 4
2019 1
2020 2
Text availability
Article attribute
Article type
Publication date

Search Results

16 results
Results by year
Filters applied: . Clear all
Page 1
Technological advances in hybrid imaging and impact on dose.
Mattsson S, Andersson M, Söderberg M. Mattsson S, et al. Among authors: andersson m. Radiat Prot Dosimetry. 2015 Jul;165(1-4):410-5. doi: 10.1093/rpd/ncv024. Epub 2015 Mar 22. Radiat Prot Dosimetry. 2015. PMID: 25802466
Clinical application of computed tomography (CT) has revolutionised medical imaging and plays an enormous role in medical care. ...In spite of significant reduction of CT doses during recent years, CT is still a dominating source of radiation exposure to the …
Clinical application of computed tomography (CT) has revolutionised medical imaging and plays an enormous role in medical care …
IDACstar: A MCNP Application to Perform Realistic Dose Estimations from Internal or External Contamination of Radiopharmaceuticals.
Ören Ü, Hiller M, Andersson M. Ören Ü, et al. Among authors: andersson m. Radiat Prot Dosimetry. 2017 Apr 28;174(3):406-411. doi: 10.1093/rpd/ncw221. Radiat Prot Dosimetry. 2017. PMID: 27475750
A Monte Carlo-based stand-alone program, IDACstar (Internal Dose Assessment by Computer), was developed, dedicated to perform radiation dose calculations using complex voxel simulations. ...An effective tool for radiation protection applications is provided with IDA …
A Monte Carlo-based stand-alone program, IDACstar (Internal Dose Assessment by Computer), was developed, dedicated to perform radiation
A biokinetic and dosimetric model for ionic indium in humans.
Andersson M, Mattsson S, Johansson L, Leide-Svegborn S. Andersson M, et al. Phys Med Biol. 2017 Jul 20;62(16):6397-6407. doi: 10.1088/1361-6560/aa779f. Phys Med Biol. 2017. PMID: 28726676
ORGAN DOSES AND EFFECTIVE DOSE FOR FIVE PET RADIOPHARMACEUTICALS.
Andersson M, Johansson L, Mattsson S, Minarik D, Leide-Svegborn S. Andersson M, et al. Radiat Prot Dosimetry. 2016 Jun;169(1-4):253-8. doi: 10.1093/rpd/ncw033. Epub 2016 Mar 13. Radiat Prot Dosimetry. 2016. PMID: 26977075
Radiation dosimetry of [(68)Ga]PSMA-11 in low-risk prostate cancer patients.
Sandgren K, Johansson L, Axelsson J, Jonsson J, Ögren M, Ögren M, Andersson M, Strandberg S, Nyholm T, Riklund K, Widmark A. Sandgren K, et al. Among authors: andersson m. EJNMMI Phys. 2019 Jan 11;6(1):2. doi: 10.1186/s40658-018-0239-2. EJNMMI Phys. 2019. PMID: 30631980 Free PMC article.
Lifetime attributable risk as an alternative to effective dose to describe the risk of cancer for patients in diagnostic and therapeutic nuclear medicine.
Andersson M, Eckerman K, Mattsson S. Andersson M, et al. Phys Med Biol. 2017 Nov 21;62(24):9177-9188. doi: 10.1088/1361-6560/aa959c. Phys Med Biol. 2017. PMID: 29064376
The radiation induced risk of cancer occurrence (incidence) or death from four nuclear medicine procedures are estimated for both male and female between 0 and 120 years. ...
The radiation induced risk of cancer occurrence (incidence) or death from four nuclear medicine procedures are estimated for both mal …
Improved estimates of the radiation absorbed dose to the urinary bladder wall.
Andersson M, Minarik D, Johansson L, Mattsson S, Leide-Svegborn S. Andersson M, et al. Phys Med Biol. 2014 May 7;59(9):2173-82. doi: 10.1088/0031-9155/59/9/2173. Epub 2014 Apr 8. Phys Med Biol. 2014. PMID: 24710713
An internal radiation dosimetry computer program, IDAC 2.0, for estimation of patient doses from radiopharmaceuticals.
Andersson M, Johansson L, Minarik D, Mattsson S, Leide-Svegborn S. Andersson M, et al. Radiat Prot Dosimetry. 2014 Dec;162(3):299-305. doi: 10.1093/rpd/nct337. Epub 2013 Dec 18. Radiat Prot Dosimetry. 2014. PMID: 24353030
The new version, IDAC2.0, incorporates the International Commission on Radiation Protection (ICRP)/ICRU computational adult male and female voxel phantoms and decay data from the ICRP publication 107. ...
The new version, IDAC2.0, incorporates the International Commission on Radiation Protection (ICRP)/ICRU computational adult male and …
IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms.
Andersson M, Johansson L, Eckerman K, Mattsson S. Andersson M, et al. EJNMMI Res. 2017 Nov 3;7(1):88. doi: 10.1186/s13550-017-0339-3. EJNMMI Res. 2017. PMID: 29098485 Free PMC article.
BACKGROUND: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. ...
BACKGROUND: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nu …
Technological advances in hybrid imaging and impact on dose.
Mattsson S, Andersson M, Söderberg M. Mattsson S, et al. Among authors: andersson m. Radiat Prot Dosimetry. 2016 Feb;168(2):292. doi: 10.1093/rpd/ncv463. Epub 2015 Oct 14. Radiat Prot Dosimetry. 2016. PMID: 26468253 Free PMC article. No abstract available.
16 results
Jump to page
Feedback