Evaluation of aerosol generator devices at 3 locations in humidified and non-humidified circuits during adult mechanical ventilation.
Ari A, Areabi H, Fink JB. Ari A, et al. Respir Care. 2010 Jul;55(7):837-44. Respir Care. 2010. PMID: 20587094
METHODS: Drug delivery from jet, vibrating-mesh, and ultrasonic nebulizers and pressurized metered-dose inhaler (pMDI) with spacer was compared in a model of adult mechanical ventilation, with heated/humidified and non-humidified ventilator circuits. ...
METHODS: Drug delivery from jet, vibrating-mesh, and ultrasonic nebulizers and pressurized metered-dose inhaler (pMDI) with spacer was compa …
Performance comparison of nebulizer designs: constant-output, breath-enhanced, and dosimetric.
Rau JL, Ari A, Restrepo RD. Rau JL, et al. Among authors: ari a. Respir Care. 2004 Feb;49(2):174-9. Respir Care. 2004. PMID: 14744267
Each nebulizer was filled with a 3-mL unit-dose of albuterol sulfate and powered by oxygen at 8 L/min. The nebulizers were connected to an induction throat, connected to a breathing simulator. ...The duration of nebulization (until sputter) was measured with a
Each nebulizer was filled with a 3-mL unit-dose of albuterol sulfate and powered by oxygen at 8 L/min. The nebulizers were connected …
Characteristics of a successful respiratory therapy education program.
Ari A, Goodfellow LT, Rau JL. Ari A, et al. Respir Care Clin N Am. 2005 Sep;11(3):371-81. doi: 10.1016/j.rcc.2005.04.010. Respir Care Clin N Am. 2005. PMID: 16168908
Connecting students to institutions: the relationship between program resources and student retention in respiratory care education programs.
Ari A. Ari A. Respir Care. 2009 Sep;54(9):1187-92. Respir Care. 2009. PMID: 19712495
After utilizing a survey research method, Pearson correlations and multiple regression analysis were used for data analysis. RESULTS: With a 63% response rate (n = 36), this study found a statistically significant relationship between program resources and st …
After utilizing a survey research method, Pearson correlations and multiple regression analysis were used for data analysis. RESULTS: …
Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.
Ari A, Atalay OT, Harwood R, Sheard MM, Aljamhan EA, Fink JB. Ari A, et al. Respir Care. 2010 Jul;55(7):845-51. Respir Care. 2010. PMID: 20587095
OBJECTIVE: To determine the influence of nebulizer position and bias flow with a jet nebulizer and a vibrating-mesh nebulizer on aerosol drug delivery in simulated and mechanically ventilated pediatric and adult patients. METHOD: Albuterol sulfate (2.5 mg) was nebul …
OBJECTIVE: To determine the influence of nebulizer position and bias flow with a jet nebulizer and a vibrating-mesh nebulizer …
Factors affecting bronchodilator delivery in mechanically ventilated adults.
Ari A, Fink JB. Ari A, et al. Nurs Crit Care. 2010 Jul-Aug;15(4):192-203. doi: 10.1111/j.1478-5153.2010.00395.x. Nurs Crit Care. 2010. PMID: 20626796 Review.
SEARCH STRATEGIES: A literature search was undertaken using several databases including Cochrane, Pubmed, Medline, Cinahl and Science Direct. ...CONCLUSION: Aerosolized bronchodilator delivery to mechanically ventilated patients is complex as a result of the multipl …
SEARCH STRATEGIES: A literature search was undertaken using several databases including Cochrane, Pubmed, Medline, Cinahl and Science …
In vitro comparison of heliox and oxygen in aerosol delivery using pediatric high flow nasal cannula.
Ari A, Harwood R, Sheard M, Dailey P, Fink JB. Ari A, et al. Pediatr Pulmonol. 2011 Aug;46(8):795-801. doi: 10.1002/ppul.21421. Epub 2011 Mar 24. Pediatr Pulmonol. 2011. PMID: 21438178
A vibrating mesh nebulizer (Aeroneb Solo, Aerogen) was placed on the inspiratory inlet of a heated humidifier and heated wire circuit attached to a pediatric nasal cannula (Optiflow, Fisher & Paykel). ...Albuterol sulfate (2.5 mg/3 ml) was administered th
A vibrating mesh nebulizer (Aeroneb Solo, Aerogen) was placed on the inspiratory inlet of a heated humidifier and heated wire
Effective bronchodilator resuscitation of children in the emergency room: device or interface?
Ari A, Fink JB. Ari A, et al. Respir Care. 2011 Jun;56(6):882-5. doi: 10.4187/respcare.01375. Respir Care. 2011. PMID: 21679497 No abstract available.
Posture perfect: the role of positioning during bronchodilator administration with oxygen or heliox.
Fink JB, Ari A. Fink JB, et al. Among authors: ari a. Respir Care. 2011 Jul;56(7):1056-7. doi: 10.4187/respcare.01410. Respir Care. 2011. PMID: 21740732 No abstract available.
Guidelines for aerosol devices in infants, children and adults: which to choose, why and how to achieve effective aerosol therapy.
Ari A, Fink JB. Ari A, et al. Expert Rev Respir Med. 2011 Aug;5(4):561-72. doi: 10.1586/ers.11.49. Expert Rev Respir Med. 2011. PMID: 21859275 Review.
This article presents the rationale for selecting the most appropriate aerosol device to administer inhaled drugs in specific patient populations, with emphasis on patient-, drug-, device- and environment-related factors and with a comparison between the available devices. …
This article presents the rationale for selecting the most appropriate aerosol device to administer inhaled drugs in specific patient popula …