Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1951 1
1952 1
1953 1
1955 1
1956 1
1958 1
1960 1
1961 2
1962 2
1963 7
1964 20
1965 7
1966 4
1967 12
1968 18
1969 20
1970 13
1971 19
1972 21
1973 20
1974 19
1975 38
1976 39
1977 44
1978 56
1979 47
1980 68
1981 61
1982 75
1983 97
1984 124
1985 112
1986 135
1987 175
1988 168
1989 222
1990 295
1991 284
1992 281
1993 354
1994 420
1995 436
1996 437
1997 497
1998 513
1999 555
2000 686
2001 762
2002 779
2003 862
2004 933
2005 1169
2006 1272
2007 1417
2008 1616
2009 1708
2010 1909
2011 2195
2012 2365
2013 2584
2014 2798
2015 2764
2016 2734
2017 2825
2018 2918
2019 2774
2020 2576
2021 1200
Text availability
Article attribute
Article type
Publication date

Search Results

40,330 results
Results by year

Citations

1 article found by citation matching

Search results

Filters applied: . Clear all
Page 1
Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review.
Jabran A, Peach C, Ren L. Jabran A, et al. Biomed Eng Online. 2018 Apr 27;17(1):47. doi: 10.1186/s12938-018-0479-3. Biomed Eng Online. 2018. PMID: 29703261 Free PMC article. Review.
In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load-displacement data, three-dimensional motion analysis systems, digital image correlation and acoustic emission testing have been used for measurement. ...This review wi …
In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load-displacement data, three-dimension …
The biomechanics of pedicle screw augmentation with cement.
Elder BD, Lo SF, Holmes C, Goodwin CR, Kosztowski TA, Lina IA, Locke JE, Witham TF. Elder BD, et al. Spine J. 2015 Jun 1;15(6):1432-45. doi: 10.1016/j.spinee.2015.03.016. Epub 2015 Mar 20. Spine J. 2015. PMID: 25797809 Review.
PURPOSE: The purpose of this study was to survey the literature and assess the previous biomechanical studies on pedicle screw augmentation with cement to provide in-depth discussions of the biomechanical benefits of multiple parameters in screw augmentation. ...The …
PURPOSE: The purpose of this study was to survey the literature and assess the previous biomechanical studies on pedicle screw augmen …
Finite Element Analysis and Biomechanical Testing of the New MiniMIS Short Stem.
Trieb K, Huber D, Sonntag R, Kretzer JP. Trieb K, et al. Z Orthop Unfall. 2019 Apr;157(2):188-193. doi: 10.1055/a-0715-2398. Epub 2019 Apr 15. Z Orthop Unfall. 2019. PMID: 30986878 English, German.
In the biomechanical tests, the total number of 10 million cycles with a maximum load of 5.34 kN was reached in all cases without any visible signs of implant damage. ...SUMMARY: The presented finite element calculation and subsequent biomechanical testing
In the biomechanical tests, the total number of 10 million cycles with a maximum load of 5.34 kN was reached in all cases with …
Biomechanics of infarcted left Ventricle-A review of experiments.
Li W. Li W. J Mech Behav Biomed Mater. 2020 Mar;103:103591. doi: 10.1016/j.jmbbm.2019.103591. Epub 2019 Dec 16. J Mech Behav Biomed Mater. 2020. PMID: 32090920 Review.
In the past decades, significant work has been devoted to this subject. Biomechanics of infarcted left ventricle (LV) is associated with MI diagnosis, understanding of remodelling, MI micro-structure and biomechanical property characterizations as well as MI therapy …
In the past decades, significant work has been devoted to this subject. Biomechanics of infarcted left ventricle (LV) is associated w …
Biomechanical analysis of spinal implants with different rod diameters under static and fatigue loads: an experimental study.
Kovacı H, Yetim AF, Çelik A. Kovacı H, et al. Biomed Tech (Berl). 2019 May 27;64(3):339-346. doi: 10.1515/bmt-2017-0236. Biomed Tech (Berl). 2019. PMID: 29935109
Spinal implants are commonly used in the treatment of spinal disorders or injuries. However, the biomechanical analyses of them are rarely investigated in terms of both biomechanical and clinical perspectives. ...In comparison to spinal implants with 5.5 mm rods, th …
Spinal implants are commonly used in the treatment of spinal disorders or injuries. However, the biomechanical analyses of them are r …
Biomechanical property and modelling of venous wall.
Li W. Li W. Prog Biophys Mol Biol. 2018 Mar;133:56-75. doi: 10.1016/j.pbiomolbio.2017.11.004. Epub 2017 Nov 21. Prog Biophys Mol Biol. 2018. PMID: 29162507 Review.
Human saphenous vein has long been used as coronary artery bypass grafts to survive a heart arrested by blocked coronary arteries. Biomechanical properties of the saphenous vein can be critical because mismatch in the biomechanical property between a coronary …
Human saphenous vein has long been used as coronary artery bypass grafts to survive a heart arrested by blocked coronary arteries. …
Biomechanical regulation of EMT and epithelial morphogenesis in amniote epiblast.
Hamidi S, Nakaya Y, Nagai H, Alev C, Shibata T, Sheng G. Hamidi S, et al. Phys Biol. 2019 Apr 23;16(4):041002. doi: 10.1088/1478-3975/ab1048. Phys Biol. 2019. PMID: 30875695 Review.
Also missing is a conceptual framework that can integrate both biomechanical and molecular parameters of the epiblast. This review is aimed at providing a background based on which epiblast morphogenesis, including its transition between the epithelial and mesenchymal stat …
Also missing is a conceptual framework that can integrate both biomechanical and molecular parameters of the epiblast. This review is …
Ageing significantly impacts the biomechanical function and structural composition of skin.
Langton AK, Graham HK, Griffiths CEM, Watson REB. Langton AK, et al. Exp Dermatol. 2019 Aug;28(8):981-984. doi: 10.1111/exd.13980. Exp Dermatol. 2019. PMID: 31152614 Free PMC article.
At photoexposed sites, biomechanical testing identified significant loss of biomechanical function-particularly in the aged cohort. ...Chronic sun exposure causes fundamental changes to the clinical and histological appearance of skin, and these are reflected …
At photoexposed sites, biomechanical testing identified significant loss of biomechanical function-particularly in the …
Understanding the Limits of Biomechanical Testing.
Roe SC. Roe SC. Vet Comp Orthop Traumatol. 2018 Feb;31(2):vi-vii. doi: 10.1055/s-0038-1637025. Epub 2018 Mar 13. Vet Comp Orthop Traumatol. 2018. PMID: 29534273 No abstract available.
Mechanical Properties of Bone Ex Vivo.
Goodyear SR, Aspden RM. Goodyear SR, et al. Methods Mol Biol. 2019;1914:241-257. doi: 10.1007/978-1-4939-8997-3_12. Methods Mol Biol. 2019. PMID: 30729468
The difference between the properties of the sample (extrinsic properties) and the properties of the material (intrinsic properties) is introduced and techniques for measuring them suggested. The addition of other tests to give a complete characterization of a bone …
The difference between the properties of the sample (extrinsic properties) and the properties of the material (intrinsic properties) is intr …
40,330 results
You have reached the last page of results. A maximum of 10,000 results are available.
Jump to page