Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens.
Montés-Micó R, Ferrer-Blasco T, Charman WN, Cerviño A, Alfonso JF, Fernández-Vega L. Montés-Micó R, et al. Among authors: cervino a. J Cataract Refract Surg. 2008 May;34(5):763-8. doi: 10.1016/j.jcrs.2008.01.017. J Cataract Refract Surg. 2008. PMID: 18471630
Postsurgical binocular visual acuity was measured over a range of effective distances. Wavefront aberrations were measured before and after surgery. ...Spherical aberration coefficients changed to negative and less positive values for a 3.0 mm and a 5.0 mm pu …
Postsurgical binocular visual acuity was measured over a range of effective distances. Wavefront aberrations were measured before and …
Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry.
González-Méijome JM, Cerviño A, Yebra-Pimentel E, Parafita MA. González-Méijome JM, et al. Among authors: cervino a. J Cataract Refract Surg. 2003 Jan;29(1):125-32. doi: 10.1016/s0886-3350(02)01815-1. J Cataract Refract Surg. 2003. PMID: 12551679
A 1-sample t test was applied to assess the significance of the relationship between Orbscan II and ultrasound methods. The relationship between the 2 was assessed by analyzing regression and plotting the differences against the mean corneal thickness. Orbscan II data were
A 1-sample t test was applied to assess the significance of the relationship between Orbscan II and ultrasound methods. The relations
Operator-induced errors in Hartmann-Shack wavefront sensing: model eye study.
Cervino A, Hosking SL, Dunne MC. Cervino A, et al. J Cataract Refract Surg. 2007 Jan;33(1):115-21. doi: 10.1016/j.jcrs.2006.09.025. J Cataract Refract Surg. 2007. PMID: 17189805
Realignment increased the standard deviation by a factor of 3 compared with the first session without realignment. CONCLUSIONS: Repeatability of the WASCA was excellent in all situations tested. ...
Realignment increased the standard deviation by a factor of 3 compared with the first session without realignment. CONCLUSIONS: Repea …
Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome.
Montés-Micó R, Rodríguez-Galietero A, Alió JL, Cerviño A. Montés-Micó R, et al. Among authors: cervino a. J Refract Surg. 2007 Feb;23(2):188-92. J Refract Surg. 2007. PMID: 17326358
The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). ...However, under mesopic conditions, a statistically significant reduction (P < …
The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriaz …
Retinal straylight in patients with monofocal and multifocal intraocular lenses.
Cerviño A, Hosking SL, Montés-Micó R, Alió JL. Cerviño A, et al. J Cataract Refract Surg. 2008 Mar;34(3):441-6. doi: 10.1016/j.jcrs.2007.11.021. J Cataract Refract Surg. 2008. PMID: 18299069
In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri. Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratori …
In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri. Smart 48 S IOL (Acri.Tec) in 20 eyes. I …
Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements.
Cerviño A, Gonzalez-Meijome JM, Linhares JM, Hosking SL, Montes-Mico R. Cerviño A, et al. Ophthalmic Physiol Opt. 2008 Mar;28(2):151-6. doi: 10.1111/j.1475-1313.2008.00541.x. Ophthalmic Physiol Opt. 2008. PMID: 18339046 Clinical Trial.
Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. ...Differences in straylight between baseline (without CL) and with the clear CL in place were neither statistically significant …
Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had …
Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye study.
Cerviño A, Bansal D, Hosking SL, Montés-Micó R. Cerviño A, et al. J Cataract Refract Surg. 2008 Jul;34(7):1089-95. doi: 10.1016/j.jcrs.2008.03.027. J Cataract Refract Surg. 2008. PMID: 18571074
METHODS: Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets …
METHODS: Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartm …
Apodized diffractive versus refractive multifocal intraocular lenses: optical and visual evaluation.
Zelichowska B, Rekas M, Stankiewicz A, Cerviño A, Montés-Micó R. Zelichowska B, et al. Among authors: cervino a. J Cataract Refract Surg. 2008 Dec;34(12):2036-42. doi: 10.1016/j.jcrs.2008.06.045. J Cataract Refract Surg. 2008. PMID: 19027556
Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes.
Ferrer-Blasco T, Montés-Micó R, Cerviño A, Alfonso JF, Fernández-Vega L. Ferrer-Blasco T, et al. Among authors: cervino a. J Cataract Refract Surg. 2008 Dec;34(12):2043-8. doi: 10.1016/j.jcrs.2008.06.046. J Cataract Refract Surg. 2008. PMID: 19027557
PURPOSE: To evaluate distance and near contrast sensitivity under photopic and mesopic conditions before and after refractive lens exchange (RLE) with implantation of a diffractive multifocal intraocular lens (IOL). ...CONCLUSIONS: Refractive lens exchange with implantatio …
PURPOSE: To evaluate distance and near contrast sensitivity under photopic and mesopic conditions before and after refractive lens exchange …