Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2003 1
2013 2
2016 1
2018 1
2021 2
2022 1
Text availability
Article attribute
Article type
Publication date

Search Results

7 results
Results by year

Citations

1 article found by citation matching

Search results

Filters applied: . Clear all
Page 1
Changes in ultrasonography indicators of abnormally invasive placenta during pregnancy.
Calì G, Timor-Trisch IE, Palacios-Jaraquemada J, Monteaugudo A, Forlani F, Minneci G, Foti F, Buca D, Familiari A, Scambia G, Liberati M, D'Antonio F. Calì G, et al. Int J Gynaecol Obstet. 2018 Mar;140(3):319-325. doi: 10.1002/ijgo.12413. Epub 2018 Jan 9. Int J Gynaecol Obstet. 2018. PMID: 29197083
OBJECTIVE: To ascertain whether the prevalence of ultrasonography signs of abnormally invasive placenta (AIP) changes during pregnancy. ...During the early first trimester, indicators of AIP were similar to those of a cesarean scar …
OBJECTIVE: To ascertain whether the prevalence of ultrasonography signs of abnormally invasive placenta (AIP) …
Uterine blood flow during various stages of pregnancy in dairy buffaloes using transrectal Doppler ultrasonography.
Varughese EE, Brar PS, Dhindsa SS. Varughese EE, et al. Anim Reprod Sci. 2013 Jul;140(1-2):34-9. doi: 10.1016/j.anireprosci.2013.05.011. Epub 2013 May 30. Anim Reprod Sci. 2013. PMID: 23773326
Thus, transrectal Doppler ultrasongraphy proved to be a useful non-invasive method to assess the uterine blood flow during pregnancy in buffaloes. This could be a valuable tool to ascertain hemodynamic changes in complicated pregnancy (e.g. abnormal
Thus, transrectal Doppler ultrasongraphy proved to be a useful non-invasive method to assess the uterine blood flow during pregnan
3D power Doppler ultrasound assessment of placental perfusion during uterine contraction in labor.
Sato M, Noguchi J, Mashima M, Tanaka H, Hata T. Sato M, et al. Placenta. 2016 Sep;45:32-6. doi: 10.1016/j.placenta.2016.06.018. Epub 2016 Jul 5. Placenta. 2016. PMID: 27577707
Only pregnancies with an entirely visualized anterior placenta were included in the study. ...Further studies involving a larger sample size are needed to assess placental perfusion and vascularity using PVS during normal and abnormal uterine contractions in …
Only pregnancies with an entirely visualized anterior placenta were included in the study. ...Further studies involving a larg …
Early Gestational Age Placenta Accreta Case Report: Can We Avoid Missed Diagnosis?
Purbadi S, Tjahjadi H, Purwoto G, Kusuma F, Winarto H, Utami TW, Indarti J, Sotarduga GE. Purbadi S, et al. Am J Case Rep. 2021 Nov 1;22:e934168. doi: 10.12659/AJCR.934168. Am J Case Rep. 2021. PMID: 34719664 Free PMC article.
BACKGROUND Placenta accreta is an abnormal invasive placenta that can be life-threatening because of the risk of hemorrhage. ...CONCLUSIONS The key point in diagnosing placenta accreta properly is to evaluate the morphometric changes base …
BACKGROUND Placenta accreta is an abnormal invasive placenta that can be life-threatening because of the risk of …
Failure of placental detachment in accreta placentation is associated with excessive fibrinoid deposition at the utero-placental interface.
Jauniaux E, Hussein AM, Elbarmelgy RM, Elbarmelgy RA, Burton GJ. Jauniaux E, et al. Am J Obstet Gynecol. 2022 Feb;226(2):243.e1-243.e10. doi: 10.1016/j.ajog.2021.08.026. Epub 2021 Aug 28. Am J Obstet Gynecol. 2022. PMID: 34461077
There have been very few detailed histopathologic studies in pregnancies complicated by placenta accreta spectrum disorders and our understanding of the pathophysiology of the condition remains limited. OBJECTIVE: To prospectively evaluate the microscopic changes
There have been very few detailed histopathologic studies in pregnancies complicated by placenta accreta spectrum disorders an …
Doppler evaluation of the effects of propofol, etomidate and alphaxalone on fetoplacental circulation hemodynamics in the pregnant ewe.
Domínguez E, Rivera Del Álamo MM, Novellas R, Espada Y, Santos L, García F, Andaluz A, Fresno L. Domínguez E, et al. Placenta. 2013 Sep;34(9):738-44. doi: 10.1016/j.placenta.2013.06.301. Epub 2013 Jul 5. Placenta. 2013. PMID: 23834950
When resistance in the fetal placenta increases, blood flow in the UA becomes more pulsatile. In the present study, umbilical arteries showed a parabolic flow with low resistance in all cases, as it occurs in normal human pregnancy. The administration of these anest …
When resistance in the fetal placenta increases, blood flow in the UA becomes more pulsatile. In the present study, umbilical arterie …
Effect of non-linearity in predicting Doppler waveforms through a novel model.
Gayasen A, Dua SK, Sengupta A, Nagchoudhuri D. Gayasen A, et al. Biomed Eng Online. 2003 Sep 18;2:16. doi: 10.1186/1475-925X-2-16. Biomed Eng Online. 2003. PMID: 14561227 Free PMC article.
Comparative analysis was done between the simulated data and the actual doppler FVW's waveforms. RESULTS & DISCUSSION: Normal pregnancy has been successfully modeled and the doppler output waveforms are simulated for different gestation time using the model. It …
Comparative analysis was done between the simulated data and the actual doppler FVW's waveforms. RESULTS & DISCUSSION: Normal …