Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Edit custom filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1997 1
2004 1
2005 1
2014 1
2022 1
2023 1
2024 1
2025 1
2026 1

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

7 results

Results by year

Filters applied: . Clear all
Page 1
Could radiofrequency echographic multispectrometry (REMS) overcome the overestimation in BMD by dual-energy X-ray absorptiometry (DXA) at the lumbar spine?
Caffarelli C, Tomai Pitinca MD, Al Refaie A, De Vita M, Catapano S, Gonnelli S. Caffarelli C, et al. BMC Musculoskelet Disord. 2022 May 19;23(1):469. doi: 10.1186/s12891-022-05430-6. BMC Musculoskelet Disord. 2022. PMID: 35590362 Free PMC article.
BACKGROUND: Osteoarthritis (OA) and vertebral fractures at the lumbar spine lead to an overestimation of bone mineral density (BMD). ...CONCLUSIONS: REMS technology by the analysis of native raw unfiltered ultrasound signals appears to be able to overcome the …
BACKGROUND: Osteoarthritis (OA) and vertebral fractures at the lumbar spine lead to an overestimation of bone mineral d …
Radiographic knee osteoarthritis is associated with higher lumbar spine bone mineral density but not reduced vertebral fracture prevalence: a retrospective cross-sectional study in older Asian women.
Huang YC, Kao SW, Chen YC, Cheng MT. Huang YC, et al. BMC Musculoskelet Disord. 2026 Mar 30;27(1):403. doi: 10.1186/s12891-026-09751-8. BMC Musculoskelet Disord. 2026. PMID: 41913142 Free PMC article.
Degenerative changes associated with OA may artifactually elevate lumbar spine BMD measured by dual-energy X-ray absorptiometry (DXA), potentially obscuring true skeletal fragility. ...Elevated spine BMD in OA may reflect degenerative artifact r …
Degenerative changes associated with OA may artifactually elevate lumbar spine BMD measured by dual-energy X-ray absorptiometr …
Pre-operative bone quality deficits and risk of complications following spine fusion surgery among postmenopausal women.
Dash AS, Billings E, Vlastaris K, Kim HJ, Cunningham ME, Raphael J, Lovecchio F, Carrino JA, Lebl D, McMahon D, Stein EM. Dash AS, et al. Osteoporos Int. 2024 Mar;35(3):551-560. doi: 10.1007/s00198-023-06963-9. Epub 2023 Nov 7. Osteoporos Int. 2024. PMID: 37932510 Free PMC article.
While skeletal complications are common, underlying skeletal deficits are often missed by pre-operative DXA due to artifact from spinal pathology. This prospective cohort study investigated pre-operative bone quality using high resolution peripheral CT (HRpQCT) and …
While skeletal complications are common, underlying skeletal deficits are often missed by pre-operative DXA due to artifact fr …
Elevated circulating Sclerostin concentrations in individuals with high bone mass, with and without LRP5 mutations.
Gregson CL, Poole KE, McCloskey EV, Duncan EL, Rittweger J, Fraser WD, Smith GD, Tobias JH. Gregson CL, et al. J Clin Endocrinol Metab. 2014 Aug;99(8):2897-907. doi: 10.1210/jc.2013-3958. Epub 2014 Feb 25. J Clin Endocrinol Metab. 2014. PMID: 24606091 Free PMC article.
DESIGN AND PARTICIPANTS: In this case-control study, 406 HBM index cases were identified by screening dual-energy x-ray absorptiometry (DXA) databases from 4 United Kingdom centers (n = 219 088), excluding significant osteoarthritis/artifact. Controls compris …
DESIGN AND PARTICIPANTS: In this case-control study, 406 HBM index cases were identified by screening dual-energy x-ray absorptiometry (D
Radiofrequency Echographic Multi Spectrometry-A Novel Tool in the Diagnosis of Osteoporosis and Prediction of Fragility Fractures: A Systematic Review.
Icătoiu E, Vlădulescu-Trandafir AI, Groșeanu LM, Berghea F, Cobilinschi CO, Potcovaru CG, Bălănescu AR, Bojincă VC. Icătoiu E, et al. Diagnostics (Basel). 2025 Feb 25;15(5):555. doi: 10.3390/diagnostics15050555. Diagnostics (Basel). 2025. PMID: 40075802 Free PMC article. Review.
Results: The reviewed studies demonstrated strong diagnostic agreement between REMS and DXA. Additionally, REMS showed enhanced diagnostic capabilities in cases where lumbar bone mineral density measurements by DXA were impaired by artifacts such as ve …
Results: The reviewed studies demonstrated strong diagnostic agreement between REMS and DXA. Additionally, REMS showed enhanced diagn …
Interobserver reproducibility of criteria for vertebral body exclusion.
Hansen KE, Binkley N, Christian R, Vallarta-Ast N, Krueger D, Drezner MK, Blank RD. Hansen KE, et al. J Bone Miner Res. 2005 Mar;20(3):501-8. doi: 10.1359/JBMR.041134. Epub 2004 Nov 29. J Bone Miner Res. 2005. PMID: 15746996 Free article.
Our results suggest that reproducibility may be improved by specifically addressing the sources of interobserver disagreement. INTRODUCTION: Although DXA is widely used to measure vertebral BMD, its interpretation is subject to multiple confounders including osteoarthri
Our results suggest that reproducibility may be improved by specifically addressing the sources of interobserver disagreement. INTRODUCTION: …
Bone mineral density of opposing hips using dual energy X-Ray absorptiometry in single-beam and fan-beam design.
Franck H, Munz M, Scherrer M. Franck H, et al. Calcif Tissue Int. 1997 Dec;61(6):445-7. doi: 10.1007/s002239900365. Calcif Tissue Int. 1997. PMID: 9383269
Bone densitometry focuses on bone mineral area density (BMD in g/cm2) of the proximal femur and spine in anterior-posterior (AP) projections. Artifacts, such as osteoarthritis and osteophytic calcifications (OC) influence spine BMD, especially in AP sc …
Bone densitometry focuses on bone mineral area density (BMD in g/cm2) of the proximal femur and spine in anterior-posterior (AP) proj …