Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Edit custom filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2012 1
2013 4
2014 4
2015 6
2016 5
2017 3
2018 7
2019 7
2020 6
2021 7
2022 12
2023 11
2024 16
2025 17
2026 14

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

97 results

Results by year

Filters applied: . Clear all
Page 1
Did you mean dexcom com accuracy mard (5 results)?
Accuracy and Safety of Dexcom G7 Continuous Glucose Monitoring in Adults with Diabetes.
Garg SK, Kipnes M, Castorino K, Bailey TS, Akturk HK, Welsh JB, Christiansen MP, Balo AK, Brown SA, Reid JL, Beck SE. Garg SK, et al. Diabetes Technol Ther. 2022 Jun;24(6):373-380. doi: 10.1089/dia.2022.0011. Epub 2022 Feb 21. Diabetes Technol Ther. 2022. PMID: 35157505 Free PMC article.
Background: We evaluated the accuracy and safety of a seventh generation (G7) Dexcom continuous glucose monitor (CGM) during 10.5 days of use in adults with diabetes. ...No serious adverse events were reported. Conclusions: The G7 CGM provides accurate …
Background: We evaluated the accuracy and safety of a seventh generation (G7) Dexcom continuous glucose monitor (CGM) d …
Significance and Reliability of MARD for the Accuracy of CGM Systems.
Reiterer F, Polterauer P, Schoemaker M, Schmelzeisen-Redecker G, Freckmann G, Heinemann L, Del Re L. Reiterer F, et al. J Diabetes Sci Technol. 2017 Jan;11(1):59-67. doi: 10.1177/1932296816662047. Epub 2016 Sep 25. J Diabetes Sci Technol. 2017. PMID: 27566735 Free PMC article.
BACKGROUND: There is a need to assess the accuracy of continuous glucose monitoring (CGM) systems for several uses. Mean absolute relative difference (MARD) is the measure of choice for this. ...Thus MARD conveys information on the accuracy of t …
BACKGROUND: There is a need to assess the accuracy of continuous glucose monitoring (CGM) systems for several uses. Mean absol …
Comparison of Point Accuracy Between Two Widely Used Continuous Glucose Monitoring Systems.
Hanson K, Kipnes M, Tran H. Hanson K, et al. J Diabetes Sci Technol. 2024 May;18(3):598-607. doi: 10.1177/19322968231225676. Epub 2024 Jan 8. J Diabetes Sci Technol. 2024. PMID: 38189290 Free PMC article.
BACKGROUND: Safe and effective self-management of glucose levels requires immediate access to accurate data. We assessed the point accuracy of the Dexcom G7 Continuous Glucose Monitoring System (Dexcom, Inc., San Diego, CA, USA) and FreeStyle Libre 3 (Abbott …
BACKGROUND: Safe and effective self-management of glucose levels requires immediate access to accurate data. We assessed the point accura
Testing the Real-World Accuracy of the Dexcom G6 Pro CGM During the Insulin-Only Bionic Pancreas Pivotal Trial.
Marak MC, Calhoun P, Damiano ER, Russell SJ, Ruedy KJ, Beck RW. Marak MC, et al. Diabetes Technol Ther. 2023 Nov;25(11):817-821. doi: 10.1089/dia.2023.0287. Epub 2023 Oct 3. Diabetes Technol Ther. 2023. PMID: 37668666 Free PMC article.
The Insulin-Only Bionic Pancreas Trial provided the opportunity to assess real-world accuracy of the blinded Dexcom G6 Pro sensor over the first 48-60 h of wear using a blood glucose meter (BGM) as a comparator for 1073 CGM-BGM pairs across 53 participants. . …
The Insulin-Only Bionic Pancreas Trial provided the opportunity to assess real-world accuracy of the blinded Dexcom G6 Pro sen …
Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes.
Alva S, Bailey T, Brazg R, Budiman ES, Castorino K, Christiansen MP, Forlenza G, Kipnes M, Liljenquist DR, Liu H. Alva S, et al. J Diabetes Sci Technol. 2022 Jan;16(1):70-77. doi: 10.1177/1932296820958754. Epub 2020 Sep 19. J Diabetes Sci Technol. 2022. PMID: 32954812 Free PMC article.
Participants aged 11+ underwent supervised glycemic manipulation during in-clinic sessions to achieve glucose levels across the measurement range of the System. Performance evaluation included accuracy measures such as the proportion of continuous glucose monitoring (CG
Participants aged 11+ underwent supervised glycemic manipulation during in-clinic sessions to achieve glucose levels across the measurement …
Performance Comparison of CGM Systems: MARD Values Are Not Always a Reliable Indicator of CGM System Accuracy.
Kirchsteiger H, Heinemann L, Freckmann G, Lodwig V, Schmelzeisen-Redeker G, Schoemaker M, Del Re L. Kirchsteiger H, et al. J Diabetes Sci Technol. 2015 Sep 1;9(5):1030-40. doi: 10.1177/1932296815586013. Print 2015 Sep. J Diabetes Sci Technol. 2015. PMID: 26330485 Free PMC article.
Most often accuracy is evaluated by the mean absolute relative difference (MARD). It is frequently overseen that MARD does not only reflect accuracy, but also the study protocol and evaluation procedure, making a cross-study comparison problematic. MET …
Most often accuracy is evaluated by the mean absolute relative difference (MARD). It is frequently overseen that MARD d …
Continuous Glucose Monitoring in the Intensive Care Unit: A Multicenter, Retrospective Hospital-Based Analysis.
Faulds ER, Hester JC, Badakhshi Y, Miller JD, Basil RC, Chandra S, Chang AS, Garcia M, Jones L, Pintor KA, Boutsicaris A, Kelly DJ, Pattison J, Reddy N, Shah R, Exline M, Davis G, Pasquel FJ, Dungan KM. Faulds ER, et al. J Diabetes Sci Technol. 2025 Jun 10:19322968251343108. doi: 10.1177/19322968251343108. Online ahead of print. J Diabetes Sci Technol. 2025. PMID: 40492314 Free PMC article.
BACKGROUND: There is limited experience with continuous glucose monitoring (CGM) in intensive care units (ICUs). This study examined CGM accuracy and changes during hemodynamic instability in ICU patients with COVID-19. ...CONCLUSION: These preliminary findin …
BACKGROUND: There is limited experience with continuous glucose monitoring (CGM) in intensive care units (ICUs). This study examined …
Accuracy of Dexcom G6 Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients With Diabetes.
Davis GM, Spanakis EK, Migdal AL, Singh LG, Albury B, Urrutia MA, Zamudio-Coronado KW, Scott WH, Doerfler R, Lizama S, Satyarengga M, Munir K, Galindo RJ, Vellanki P, Cardona S, Pasquel FJ, Peng L, Umpierrez GE. Davis GM, et al. Diabetes Care. 2021 Jul;44(7):1641-1646. doi: 10.2337/dc20-2856. Epub 2021 Jun 7. Diabetes Care. 2021. PMID: 34099515 Free PMC article.
OBJECTIVE: Advances in continuous glucose monitoring (CGM) have transformed ambulatory diabetes management. Until recently, inpatient use of CGM has remained investigational, with limited data on its accuracy in the hospital setting. RESEARCH DESIGN AND METHO …
OBJECTIVE: Advances in continuous glucose monitoring (CGM) have transformed ambulatory diabetes management. Until recently, inpatient …
Real-world Accuracy of CGM in Inpatient Critical and Noncritical Care Settings at a Safety-Net Hospital.
Finn E, Schlichting L, Grau L, Douglas IS, Pereira RI. Finn E, et al. Diabetes Care. 2023 Oct 1;46(10):1825-1830. doi: 10.2337/dc23-0089. Diabetes Care. 2023. PMID: 37561954 Free PMC article.
CGM accuracy was evaluated. RESULTS: Paired readings (2,744 POC-CGM; 3,705 Lab-CGM) were analyzed for 233 patients with 239 encounters (83 NCI, 156 CI). ...Lab-CGM aggregated and average MARDs were 11.4% and 12.2%. Accuracy for POC-CGM
CGM accuracy was evaluated. RESULTS: Paired readings (2,744 POC-CGM; 3,705 Lab-CGM) were analyzed for 233 patien
Accuracy of continuous glucose monitoring in the hospital setting: an observational study.
O'Connor MY, Flint KL, Sabean A, Ashley A, Zheng H, Yan J, Steiner BA, Anandakugan N, Calverley M, Bartholomew R, Greaux E, Larkin M, Russell SJ, Putman MS. O'Connor MY, et al. Diabetologia. 2024 Dec;67(12):2650-2659. doi: 10.1007/s00125-024-06250-0. Epub 2024 Aug 10. Diabetologia. 2024. PMID: 39126488 Free PMC article.
AIMS/HYPOTHESIS: Continuous glucose monitoring (CGM) improves glycaemic outcomes in the outpatient setting; however, there are limited data regarding CGM accuracy in hospital. ...Key accuracy metrics included the proportion of CGM values within …
AIMS/HYPOTHESIS: Continuous glucose monitoring (CGM) improves glycaemic outcomes in the outpatient setting; however, there are limite …