Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2008 1
2009 4
2010 1
2011 2
2012 3
2013 2
2014 3
2015 3
2016 4
2017 5
2018 4
2019 3
2020 6
2021 4
2022 4
Text availability
Article attribute
Article type
Publication date

Search Results

44 results
Results by year
Filters applied: . Clear all
Page 1
EyeSeeCam: an eye movement-driven head camera for the examination of natural visual exploration.
Schneider E, Villgrattner T, Vockeroth J, Bartl K, Kohlbecher S, Bardins S, Ulbrich H, Brandt T. Schneider E, et al. Ann N Y Acad Sci. 2009 May;1164:461-7. doi: 10.1111/j.1749-6632.2009.03858.x. Ann N Y Acad Sci. 2009. PMID: 19645949
The prototype of a gaze-controlled, head-mounted camera (EyeSeeCam) was developed that provides the functionality for fundamental studies on human gaze behavior even under dynamic conditions like locomotion. EyeSeeCam incorporates active visual exploration by saccad …
The prototype of a gaze-controlled, head-mounted camera (EyeSeeCam) was developed that provides the functionality for fundamental stu …
Quantitative comparison of a mobile and a stationary video-based eye-tracker.
Dowiasch S, Wolf P, Bremmer F. Dowiasch S, et al. Behav Res Methods. 2020 Apr;52(2):667-680. doi: 10.3758/s13428-019-01267-5. Behav Res Methods. 2020. PMID: 31240632 Free PMC article.
To get a better understanding of the advantages and limitations of modern mobile eye-trackers, we quantitatively compared one of the most advanced mobile eye-trackers available, the EyeSeeCam, with a commonly used laboratory eye-tracker, the EyeLink II, serving as a gold s …
To get a better understanding of the advantages and limitations of modern mobile eye-trackers, we quantitatively compared one of the most ad …
A wearable video-oculography based evaluation of saccades and respective clinical correlates in patients with early onset ataxia.
Summa S, Schirinzi T, Favetta M, Romano A, Minosse S, Diodato D, Olivieri G, Martinelli D, Sancesario A, Zanni G, Castelli E, Bertini E, Petrarca M, Vasco G. Summa S, et al. J Neurosci Methods. 2020 May 15;338:108697. doi: 10.1016/j.jneumeth.2020.108697. Epub 2020 Mar 20. J Neurosci Methods. 2020. PMID: 32205159 Review.
In FRDA the amplitude of horizontal saccades directly correlated with SARA score. COMPARISON WITH EXISTING METHOD: EyeSeeCam allowed testing saccades easily and quickly even in pediatric patients with EOA. ...Since such differences may reflect distinct pathophysiological s …
In FRDA the amplitude of horizontal saccades directly correlated with SARA score. COMPARISON WITH EXISTING METHOD: EyeSeeCam allowed …
Eye movement biomarkers allow for the definition of phenotypes in Gaucher Disease.
Donald A, Tan CY, Chakrapani A, Hughes DA, Sharma R, Cole D, Bardins S, Gorges M, Jones SA, Schneider E. Donald A, et al. Orphanet J Rare Dis. 2020 Dec 17;15(1):349. doi: 10.1186/s13023-020-01637-9. Orphanet J Rare Dis. 2020. PMID: 33334373 Free PMC article.
METHODS: We undertook a study to evaluate saccadic eye movements in Gaucher patients and to assess the role of the EyeSeeCam in measuring saccades. The EyeSeeCam is a video-oculography device which was used to run a protocol of saccade measures. ...
METHODS: We undertook a study to evaluate saccadic eye movements in Gaucher patients and to assess the role of the EyeSeeCam in measu …
Mobile three dimensional gaze tracking.
Stoll J, Kohlbecher S, Marx S, Schneider E, Einhäuser W. Stoll J, et al. Stud Health Technol Inform. 2011;163:616-22. Stud Health Technol Inform. 2011. PMID: 21335867
Mobile eyetracking is a recent method enabling research on attention during real-life behavior. With the EyeSeeCam, we have recently presented a mobile eye-tracking device, whose camera-motion device (gazecam) records movies orientated in user's direction of gaze. Here we …
Mobile eyetracking is a recent method enabling research on attention during real-life behavior. With the EyeSeeCam, we have recently …
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects.
Felipe L. Felipe L. Arq Neuropsiquiatr. 2021 Jul;79(7):571-578. doi: 10.1590/0004-282X-ANP-2020-0301. Arq Neuropsiquiatr. 2021. PMID: 34468495 Free article.
The results from two systems: 1. ICS Impulse (Otometrics/Natus, Denmark) and 2. EyeSeeCam (InterAcoustics, Denmark) were recorded. The same operator delivered every impulse to every subject. ...CONCLUSIONS: The vHIT is an important tool for otoneurological complementary ev …
The results from two systems: 1. ICS Impulse (Otometrics/Natus, Denmark) and 2. EyeSeeCam (InterAcoustics, Denmark) were recorded. Th …
Prevalence, Determinants, and Consequences of Vestibular Hypofunction. Results From the KORA-FF4 Survey.
Grill E, Heuberger M, Strobl R, Saglam M, Holle R, Linkohr B, Ladwig KH, Peters A, Schneider E, Jahn K, Lehnen N. Grill E, et al. Front Neurol. 2018 Dec 7;9:1076. doi: 10.3389/fneur.2018.01076. eCollection 2018. Front Neurol. 2018. PMID: 30581415 Free PMC article.
During head impulses, head movements were measured with inertial sensors, eye movements with video-oculography (EyeSeeCam vHIT). Results: A total of 2,279 participants were included (mean age 60.8 years, 51.6% female), 570 (25.0%) with moderate or severe vertigo or dizzine …
During head impulses, head movements were measured with inertial sensors, eye movements with video-oculography (EyeSeeCam vHIT). Resu …
Instantaneous Gain in Video Head Impulse Test: A Reliability Study.
Kabiş B, Tutar H, Gündüz B, Aksoy S. Kabiş B, et al. Turk Arch Otorhinolaryngol. 2022 Mar;60(1):16-22. doi: 10.4274/tao.2022.2022-1-4. Epub 2022 May 12. Turk Arch Otorhinolaryngol. 2022. PMID: 35634233 Free PMC article.
The purpose of this study was to investigate the reliability of instantaneous gain values at 40, 60, and 80 ms with testing and retesting in healthy adults. METHODS: The study was conducted with Interacoustics EyeSeeCam vHIT (Interacoustics, Denmark), and 42 healthy adults …
The purpose of this study was to investigate the reliability of instantaneous gain values at 40, 60, and 80 ms with testing and retesting in …
Are gain values significantly altered by manual data selection when performing the video Head Impulse Test (v-HIT) on all six semicircular canals with two different v-HIT systems.
Abrahamsen ER, Skals RK, Hougaard DD. Abrahamsen ER, et al. J Vestib Res. 2020;30(5):305-317. doi: 10.3233/VES-200717. J Vestib Res. 2020. PMID: 33044206
METHOD: 120 subjects with previously neither vestibular nor neurological disorders underwent four separate tests of all six SCCs with either EyeSeeCam or ICS Impulse. All v-HIT test reports underwent manual data selection by an experienced ENT Specialist with deletion of a …
METHOD: 120 subjects with previously neither vestibular nor neurological disorders underwent four separate tests of all six SCCs with either …
44 results