Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

180 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
Gravity-dependent phenomena in lung ventilation determined by functional EIT.
Frerichs I, Hahn G, Hellige G. Frerichs I, et al. Physiol Meas. 1996 Nov;17 Suppl 4A:A149-57. doi: 10.1088/0967-3334/17/4a/019. Physiol Meas. 1996. PMID: 9001613
Local mechanics of the lung tissue determined by functional EIT.
Hahn G, Frerichs I, Kleyer M, Hellige G. Hahn G, et al. Among authors: frerichs i. Physiol Meas. 1996 Nov;17 Suppl 4A:A159-66. doi: 10.1088/0967-3334/17/4a/020. Physiol Meas. 1996. PMID: 9001614
[Determining local lung ventilation by functional electrical impedance tomography under clinical circumstances].
Hahn G, Frerichs I, Golisch W, Kurpitz M, Schröder T, Hellige G. Hahn G, et al. Among authors: frerichs i. Biomed Tech (Berl). 1997;42 Suppl:213-4. doi: 10.1515/bmte.1997.42.s2.213. Biomed Tech (Berl). 1997. PMID: 9517119 German. No abstract available.
Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography.
Frerichs I, Hahn G, Golisch W, Kurpitz M, Burchardi H, Hellige G. Frerichs I, et al. Acta Anaesthesiol Scand. 1998 Jul;42(6):721-6. doi: 10.1111/j.1399-6576.1998.tb05308.x. Acta Anaesthesiol Scand. 1998. PMID: 9689281
Sixteen ECG electrodes were placed on the circumference of the thorax and connected with an EIT device (APT System Mark I, IBEES, Sheffield, UK). ...
Sixteen ECG electrodes were placed on the circumference of the thorax and connected with an EIT device (APT System Mark I, IBEES, She …
Electrical impedance tomography in monitoring experimental lung injury.
Frerichs I, Hahn G, Schröder T, Hellige G. Frerichs I, et al. Intensive Care Med. 1998 Aug;24(8):829-36. doi: 10.1007/s001340050673. Intensive Care Med. 1998. PMID: 9757928
A simple method to check the dynamic performance of electrical impedance tomography systems.
Hahn G, Beer M, Frerichs I, Dudykevych T, Schröder T, Hellige G. Hahn G, et al. Among authors: frerichs i. Physiol Meas. 2000 Feb;21(1):53-60. doi: 10.1088/0967-3334/21/1/307. Physiol Meas. 2000. PMID: 10719999
Quantitative evaluation of the performance of different electrical tomography devices.
Hahn G, Thiel F, Dudykevych T, Frerichs I, Gersing E, Schröder T, Hartung C, Hellige G. Hahn G, et al. Among authors: frerichs i. Biomed Tech (Berl). 2001 Apr;46(4):91-5. doi: 10.1515/bmte.2001.46.4.91. Biomed Tech (Berl). 2001. PMID: 11388040
Two widely used electrical tomography systems, the Sheffield Mark I and the DAS-01P, were quantitatively evaluated and compared to the newly developed Goe-MF system. ...Our results demonstrate that adequate averaging is necessary for noise reduction for the Mark I a …
Two widely used electrical tomography systems, the Sheffield Mark I and the DAS-01P, were quantitatively evaluated and compared to th …
180 results
Jump to page
Feedback