Experimental rotator cuff repair. A preliminary study.
Gerber C, Schneeberger AG, Perren SM, Nyffeler RW. Gerber C, et al. J Bone Joint Surg Am. 1999 Sep;81(9):1281-90. doi: 10.2106/00004623-199909000-00009. J Bone Joint Surg Am. 1999. PMID: 10505524
Failure of suture material at suture anchor eyelets.
Meyer DC, Nyffeler RW, Fucentese SF, Gerber C. Meyer DC, et al. Arthroscopy. 2002 Nov-Dec;18(9):1013-9. doi: 10.1053/jars.2002.36115. Arthroscopy. 2002. PMID: 12426545
Mechanical strength of arthroscopic rotator cuff repair techniques: an in vitro study.
Schneeberger AG, von Roll A, Kalberer F, Jacob HA, Gerber C. Schneeberger AG, et al. J Bone Joint Surg Am. 2002 Dec;84(12):2152-60. doi: 10.2106/00004623-200212000-00005. J Bone Joint Surg Am. 2002. PMID: 12473702
Mechanical testing of absorbable suture anchors.
Meyer DC, Fucentese SF, Ruffieux K, Jacob HA, Gerber C. Meyer DC, et al. Arthroscopy. 2003 Feb;19(2):188-93. doi: 10.1053/jars.2003.50015. Arthroscopy. 2003. PMID: 12579152
Testing temperature was 37 degrees C +/- 1 degrees C. The anchors were loaded with an Instron testing machine with the suture material (USP No. 2, Ethibond, Ethicon, Somerville, NJ) in line with the anchor axis, with and without previous abrasion of the suture at th …
Testing temperature was 37 degrees C +/- 1 degrees C. The anchors were loaded with an Instron testing machine with the suture …
The use of acrylic bone cement for suture anchoring.
Meyer DC, Jacob HA, Pistoia W, von Roll A, Gerber C. Meyer DC, et al. Clin Orthop Relat Res. 2003 May;(410):295-302. doi: 10.1097/01.blo.0000063785.32430.f9. Clin Orthop Relat Res. 2003. PMID: 12771844
Influence of test temperature and test speed on the mechanical strength of absorbable suture anchors.
Meyer DC, Felix E, Ruffieux K, Gerber C. Meyer DC, et al. Arthroscopy. 2004 Feb;20(2):185-90. doi: 10.1016/j.arthro.2003.11.014. Arthroscopy. 2004. PMID: 14760353
Testing temperature was 20 degrees C +/- 1 degrees C or 37 degrees C +/- 1 degrees C, test speed was 50 mm/min or 5 mm/min. Tensile load at failure and failure mode were recorded. ...Increase of temperature (20 degrees C to 37 degrees C) …
Testing temperature was 20 degrees C +/- 1 degrees C or 37 degrees C +/- 1 degrees C, test speed was 50 mm/min o …
Association of osteopenia of the humeral head with full-thickness rotator cuff tears.
Meyer DC, Fucentese SF, Koller B, Gerber C. Meyer DC, et al. J Shoulder Elbow Surg. 2004 May-Jun;13(3):333-7. doi: 10.1016/j.jse.2003.12.016. J Shoulder Elbow Surg. 2004. PMID: 15111905