Histopathological evaluation of a novel radiofrequency surgical ablation system.
Saltman AE, Raju NR, Block JE. Saltman AE, et al. Innovations (Phila). 2008 Mar;3(2):47-51. doi: 10.1097/IMI.0b013e31817677a4. Innovations (Phila). 2008. PMID: 22436765
PURPOSE: : Using a porcine model, this feasibility study was undertaken to evaluate the histopathological characteristics of lesions created in the proximity of the pulmonary veins after ablation with a new endoscopic-guided radiofrequency device. METH …
PURPOSE: : Using a porcine model, this feasibility study was undertaken to evaluate the histopathological characteristics of l …
Evaluation of a novel epicardial atrial fibrillation treatment system.
Kiser AC, Nifong LW, Raman J, Kasirajan V, Campbell N, Chitwood WR Jr. Kiser AC, et al. Ann Thorac Surg. 2008 Jan;85(1):300-3. doi: 10.1016/j.athoracsur.2007.05.061. Ann Thorac Surg. 2008. PMID: 18154827
A novel system developed to create epicardial ablation lesions during beating-heart surgical procedures was evaluated in an in vivo ovine model. DESCRIPTION: This novel ablation device integrates radiofrequency, sucti …
A novel system developed to create epicardial ablation lesions during beating-heart surgical procedures w …
Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter.
Evonich RF, Nori DM, Haines DE. Evonich RF, et al. J Interv Card Electrophysiol. 2012 Jun;34(1):29-36. doi: 10.1007/s10840-011-9646-1. Epub 2012 Jan 8. J Interv Card Electrophysiol. 2012. PMID: 22228411
BACKGROUND: Due to the variable anatomy of the human pulmonary vein (PV), PV isolation for atrial fibrillation ablation is challenging. A novel hot balloon ablation catheter has been developed to improve ablation outcomes. ...PVs ablated at temp …
BACKGROUND: Due to the variable anatomy of the human pulmonary vein (PV), PV isolation for atrial fibrillation ablation is challengin …
A novel non-vascular system to treat resistant hypertension.
Heuser RR, Mhatre AU, Buelna TJ, Berci WL, Hubbard BS. Heuser RR, et al. EuroIntervention. 2013 May 20;9(1):135-9. doi: 10.4244/EIJV9I1A19. EuroIntervention. 2013. PMID: 23685301 Free article.
AIMS: To evaluate in a preclinical model the utility of a monopolar electrode catheter delivering radiofrequency (RF) energy placed into the renal pelvis in order to treat resistant hypertension (RH). ...Histopathology confirmed nerve ablation in the treated …
AIMS: To evaluate in a preclinical model the utility of a monopolar electrode catheter delivering radiofrequency (RF) energy p …
Targeted lung denervation in sheep: durability of denervation and long-term histologic effects on bronchial wall and peribronchial structures.
Mayse ML, Norman HS, Peterson AD, Rouw KT, Johnson PJ. Mayse ML, et al. Respir Res. 2020 May 18;21(1):117. doi: 10.1186/s12931-020-01383-3. Respir Res. 2020. PMID: 32423414 Free PMC article.
While procedural safety and impact on clinical outcomes have recently been reported, the mechanism of action has not been reported. We explored the long-term pathologic and histopathologic effects in a sheep model of ablation of bronchial branches of the vagus nerve …
While procedural safety and impact on clinical outcomes have recently been reported, the mechanism of action has not been reported. We explo …
Catheter mounted coaxially moveable ablation electrode for the creation of linear transmural endocardial lesions.
Morgan JM, Roberts PR, Allen S, Gallagher PJ, Gibson C, Cunningham AD. Morgan JM, et al. J Cardiovasc Electrophysiol. 1999 Apr;10(4):566-73. doi: 10.1111/j.1540-8167.1999.tb00714.x. J Cardiovasc Electrophysiol. 1999. PMID: 10355699
Bipolar or unipolar electrograms can be recorded from electrodes on the catheter tip and the coaxially moving ablation. Radiofrequency (RF) current is delivered to the coaxially moving ablation electrode with thermocouple temperature control. This ablation
Bipolar or unipolar electrograms can be recorded from electrodes on the catheter tip and the coaxially moving ablation. Radiofrequ