Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1976 1
1977 1
1978 1
1979 1
1980 2
1981 1
1982 1
1983 1
1984 3
1985 4
1986 1
1987 1
1988 2
1989 3
1990 5
1991 2
1992 2
1993 4
1994 2
1995 3
1996 2
1997 4
1998 4
1999 3
2000 4
2001 1
2002 3
2003 3
2004 7
2005 2
2006 2
2007 2
2008 3
2009 3
2010 8
2011 4
2012 6
2013 5
2014 9
2015 14
2016 8
2017 7
2018 3
2019 13
2020 7
2021 4
2022 8
2023 9
2024 13
2025 0

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

180 results

Results by year

Filters applied: . Clear all
Page 1
[Acute compartment syndrome].
Hansen EL, Pedersen L, Lindberg-Larsen M. Hansen EL, et al. Ugeskr Laeger. 2021 Jul 5;183(27):V11200817. Ugeskr Laeger. 2021. PMID: 34219642 Free article. Review. Danish.
Acute compartment syndrome is a clinical diagnosis, which in equivocal cases can be supported by direct intra-compartmental pressure measurement and laboratory values. Imaging can detect fractures; and non-invasive monitoring is under investigation but has not yet f …
Acute compartment syndrome is a clinical diagnosis, which in equivocal cases can be supported by direct intra-compartmental pressure
Diagnosis and treatment of acute extremity compartment syndrome.
von Keudell AG, Weaver MJ, Appleton PT, Bae DS, Dyer GSM, Heng M, Jupiter JB, Vrahas MS. von Keudell AG, et al. Lancet. 2015 Sep 26;386(10000):1299-1310. doi: 10.1016/S0140-6736(15)00277-9. Lancet. 2015. PMID: 26460664 Review.
Despite many studies, there is no consensus about the way in which acute extremity compartment syndromes should be diagnosed. Many surgeons suggest continuous monitoring of intracompartmental pressure for all patients who have high-risk extremity injuries, wh …
Despite many studies, there is no consensus about the way in which acute extremity compartment syndromes should be diagnosed. Many surgeons …
Pressure Measurement: Surrogate of Ischaemia.
Duckworth AD, Court-Brown CM, McQueen MM. Duckworth AD, et al. 2019 Sep 3. In: Mauffrey C, Hak DJ, Martin III MP, editors. Compartment Syndrome: A Guide to Diagnosis and Management [Internet]. Cham (CH): Springer; 2019. Chapter 5. 2019 Sep 3. In: Mauffrey C, Hak DJ, Martin III MP, editors. Compartment Syndrome: A Guide to Diagnosis and Management [Internet]. Cham (CH): Springer; 2019. Chapter 5. PMID: 32091733 Free Books & Documents. Review.
Although combining symptoms and signs can improve the sensitivity, this will often mean irreversible disability has developed e.g. paralysis. Intracompartmental pressure monitoring of at risk patients has recently been found to have a high sensitivity (94%) a …
Although combining symptoms and signs can improve the sensitivity, this will often mean irreversible disability has developed e.g. paralysis …
Noninvasive Technique to Monitor the Pressure under a Cast: A Mobile Application-Friendly Bluetooth Pressure Sensor.
Mahirogullari M, Surucu S, Cerci MH, Aydin M, Kayikli A, Gunduz O. Mahirogullari M, et al. Int J Clin Pract. 2022 Oct 31;2022:9093612. doi: 10.1155/2022/9093612. eCollection 2022. Int J Clin Pract. 2022. PMID: 36406479 Free PMC article.
AIM: The purpose of this study was to design a sensor that could monitor the skin-cast contact surface pressure (SCCSP) of a limb under a cast and inform the user via a mobile application when the pressure increases. ...CONCLUSION: We can monitor SCCSP …
AIM: The purpose of this study was to design a sensor that could monitor the skin-cast contact surface pressure (SCCSP) of a l …
Intracompartmental Pressure Monitoring Using a Handheld Pressure Monitoring System.
Halanski MA, Morris MR, Lee Harper B, Doro C. Halanski MA, et al. JBJS Essent Surg Tech. 2015 Mar 25;5(1):e6. doi: 10.2106/JBJS.ST.N.00020. eCollection 2015 Feb 25. JBJS Essent Surg Tech. 2015. PMID: 30473914 Free PMC article.
INTRODUCTION: We describe the correct technique for measuring compartment pressure with a handheld device to diagnose compartment syndrome. STEP 1 DEVICE PREPARATION: Proper preparation of the handheld pressure monitoring device (Stryker Surgical, Kalamazoo, …
INTRODUCTION: We describe the correct technique for measuring compartment pressure with a handheld device to diagnose compartment syn …
Intracompartmental pressure in lower leg muscles and tibial nerve in healthy volunteers correlate to the stiffness measured using shear wave elastography.
Yuri T, Oyama S, Giambini H. Yuri T, et al. Clin Biomech (Bristol). 2022 Jan;91:105539. doi: 10.1016/j.clinbiomech.2021.105539. Epub 2021 Nov 22. Clin Biomech (Bristol). 2022. PMID: 34837861
BACKGROUND: Acute compartment syndrome in the lower leg is a painful condition characterized by an increase in intracompartmental pressure. To prevent misdiagnosis and delay in the recognition of the condition, which can lead to severe complications, continuous m
BACKGROUND: Acute compartment syndrome in the lower leg is a painful condition characterized by an increase in intracompartmental
Intracompartmental pressure as a predictor of intratesticular blood flow: a rat model.
Watson MJ, Bartkowski DP, Nelson NC. Watson MJ, et al. J Urol. 2015 Jun;193(6):2062-7. doi: 10.1016/j.juro.2014.12.018. Epub 2014 Dec 10. J Urol. 2015. PMID: 25498571
The testicle of each rat was delivered from the scrotum and size measurements were taken. An intracompartment pressure monitor needle was inserted into the testis to record basal intratesticular pressure. ...CONCLUSIONS: This is the first known study to chara …
The testicle of each rat was delivered from the scrotum and size measurements were taken. An intracompartment pressure monitor
Intravenous Mannitol reduces intracompartmental pressure following tibia fractures: A randomized controlled trial.
Nesaraj J, Varghese VD, Boopalan PR, Nithyananth M, Sudarsanam TD, Jepegnanam TS. Nesaraj J, et al. Chin J Traumatol. 2021 Mar;24(2):109-112. doi: 10.1016/j.cjtee.2020.11.006. Epub 2020 Nov 20. Chin J Traumatol. 2021. PMID: 33288404 Free PMC article. Clinical Trial.
They were allocated into 2 groups by the investigator using computer generated randomization. The pressure in the anterior compartment of the leg was measured with a handheld Stryker pressure monitor. ...RESULTS: There was no difference in intracompartment
They were allocated into 2 groups by the investigator using computer generated randomization. The pressure in the anterior compartmen …
Compartment Syndrome of the Hand.
Oak NR, Abrams RA. Oak NR, et al. Orthop Clin North Am. 2016 Jul;47(3):609-16. doi: 10.1016/j.ocl.2016.03.006. Orthop Clin North Am. 2016. PMID: 27241383 Review.
Hand compartment syndrome has many etiologies; untreated, it has dire functional consequences. Intracompartmental pressure exceeding capillary filling pressure causes decreased tissue perfusion resulting in progressive ischemic death of compartment contents. …
Hand compartment syndrome has many etiologies; untreated, it has dire functional consequences. Intracompartmental pressure exc …
180 results