Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

120 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
Reaction-diffusion master equation, diffusion-limited reactions, and singular potentials.
Isaacson SA, Isaacson D. Isaacson SA, et al. Among authors: isaacson d. Phys Rev E Stat Nonlin Soft Matter Phys. 2009 Dec;80(6 Pt 2):066106. doi: 10.1103/PhysRevE.80.066106. Epub 2009 Dec 7. Phys Rev E Stat Nonlin Soft Matter Phys. 2009. PMID: 20365230 Free PMC article.
Isaacson, SIAM J. Appl. Math. 70, 77 (2009)]. The approximation was shown to be divergent in the limit that the lattice spacing in the RDME approached zero. ...
Isaacson, SIAM J. Appl. Math. 70, 77 (2009)]. The approximation was shown to be divergent in the limit that the lattice spacing in th
Reconstruction of conductivity changes due to ventilation and perfusion from EIT data collected on a rectangular electrode array.
Mueller JL, Isaacson D, Newell JC. Mueller JL, et al. Among authors: isaacson d. Physiol Meas. 2001 Feb;22(1):97-106. doi: 10.1088/0967-3334/22/1/313. Physiol Meas. 2001. PMID: 11236896
A direct reconstruction algorithm for electrical impedance tomography.
Mueller JL, Siltanen S, Isaacson D. Mueller JL, et al. Among authors: isaacson d. IEEE Trans Med Imaging. 2002 Jun;21(6):555-9. doi: 10.1109/TMI.2002.800574. IEEE Trans Med Imaging. 2002. PMID: 12166850
A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional geometry is reviewed. ...Nachman [1996] for the 2-D inverse conductivity problem. In this geometry, several of the clinical application …
A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional ge …
Estimating a regional ventilation-perfusion index.
Muller PA, Li T, Isaacson D, Newell JC, Saulnier GJ, Kao TJ, Ashe J. Muller PA, et al. Among authors: isaacson d. Physiol Meas. 2015 Jun;36(6):1283-95. doi: 10.1088/0967-3334/36/6/1283. Epub 2015 May 26. Physiol Meas. 2015. PMID: 26006279 Free PMC article.
Electrode boundary conditions and experimental validation for BEM-based EIT forward and inverse solutions.
Babaeizadeh S, Brooks DH, Isaacson D, Newell JC. Babaeizadeh S, et al. Among authors: isaacson d. IEEE Trans Med Imaging. 2006 Sep;25(9):1180-8. doi: 10.1109/tmi.2006.879957. IEEE Trans Med Imaging. 2006. PMID: 16967803
A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry.
Choi MH, Kao TJ, Isaacson D, Saulnier GJ, Newell JC. Choi MH, et al. Among authors: isaacson d. IEEE Trans Biomed Eng. 2007 Apr;54(4):700-10. doi: 10.1109/TBME.2006.890139. IEEE Trans Biomed Eng. 2007. PMID: 17405377 Free PMC article.
Phasic three-dimensional impedance imaging of cardiac activity.
Newell JC, Blue RS, Isaacson D, Saulnier GJ, Ross AS. Newell JC, et al. Among authors: isaacson d. Physiol Meas. 2002 Feb;23(1):203-9. doi: 10.1088/0967-3334/23/1/321. Physiol Meas. 2002. PMID: 11876235 Clinical Trial.
Calderón's method on an elliptical domain.
Muller PA, Isaacson D, Newell JC, Saulnier GJ. Muller PA, et al. Among authors: isaacson d. Physiol Meas. 2013 Jun;34(6):609-22. doi: 10.1088/0967-3334/34/6/609. Epub 2013 May 29. Physiol Meas. 2013. PMID: 23719023 Free PMC article.
A compensated radiolucent electrode array for combined EIT and mammography.
Kao TJ, Saulnier GJ, Xia H, Tamma C, Newell JC, Isaacson D. Kao TJ, et al. Among authors: isaacson d. Physiol Meas. 2007 Jul;28(7):S291-9. doi: 10.1088/0967-3334/28/7/S22. Epub 2007 Jun 26. Physiol Meas. 2007. PMID: 17664644 Free PMC article.
Imaging cardiac activity by the D-bar method for electrical impedance tomography.
Isaacson D, Mueller JL, Newell JC, Siltanen S. Isaacson D, et al. Physiol Meas. 2006 May;27(5):S43-50. doi: 10.1088/0967-3334/27/5/S04. Epub 2006 Apr 18. Physiol Meas. 2006. PMID: 16636419 Free PMC article.
A practical D-bar algorithm for reconstructing conductivity changes from EIT data taken on electrodes in a 2D geometry is described. ...
A practical D-bar algorithm for reconstructing conductivity changes from EIT data taken on electrodes in a 2D geometry is described. …
120 results
Jump to page
Feedback