Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2014 1
2015 2
2016 1
2017 1
2018 5
2019 3
2020 1
2022 1
2026 0

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

13 results

Results by year

Filters applied: . Clear all
Page 1
The Weiss Ring, a Major Confounding Factor For Measurements of Peripapillary Retinal Nerve Fiber Layer Thickness: Short title: The Impact of the Weiss Ring On RNFL Thickness Measurements.
Lee MW, Kim MS, Yu HY, Park KS, Lee YH, Kim JY. Lee MW, et al. Among authors: kim jy. Am J Ophthalmol. 2022 Jun;238:134-140. doi: 10.1016/j.ajo.2022.01.001. Epub 2022 Jan 14. Am J Ophthalmol. 2022. PMID: 35038416
This could be a major confounding factor for analyses of pRNFL changes, especially in glaucoma patients....
This could be a major confounding factor for analyses of pRNFL changes, especially in glaucoma patients....
Using the Thickness Map from Macular Ganglion Cell Analysis to Differentiate Retinal Vein Occlusion from Glaucoma.
Lee NH, Park KS, Lee HM, Kim JY, Kim CS, Kim KN. Lee NH, et al. Among authors: kim jy. J Clin Med. 2020 Oct 14;9(10):3294. doi: 10.3390/jcm9103294. J Clin Med. 2020. PMID: 33066685 Free PMC article.
PURPOSE: We hypothesized that the thickness map from macular ganglion cell analysis (GCA) acquired from spectral-domain optical coherence tomography can be used to differentiate retinal vein occlusion (RVO) from glaucoma. METHODS: In this retrospective case control study, …
PURPOSE: We hypothesized that the thickness map from macular ganglion cell analysis (GCA) acquired from spectral-domain optical coherence to …
Signal Strength as an Important Factor in the Analysis of Peripapillary Microvascular Density Using Optical Coherence Tomography Angiography.
Lim HB, Kim YW, Nam KY, Ryu CK, Jo YJ, Kim JY. Lim HB, et al. Among authors: kim jy. Sci Rep. 2019 Nov 8;9(1):16299. doi: 10.1038/s41598-019-52818-x. Sci Rep. 2019. PMID: 31705032 Free PMC article.
SS is a significant factor affecting peripapillary microvascular density, and its influence is similar to well-known structural parameters associated with glaucoma....
SS is a significant factor affecting peripapillary microvascular density, and its influence is similar to well-known structural parameters a …
Relationship between preoperative high intraocular pressure and retinal nerve fibre layer thinning after glaucoma surgery.
Kim WJ, Kim KN, Sung JY, Kim JY, Kim CS. Kim WJ, et al. Among authors: kim jy. Sci Rep. 2019 Sep 25;9(1):13901. doi: 10.1038/s41598-019-50406-7. Sci Rep. 2019. PMID: 31554879 Free PMC article.

A total of 60 patients (60 eyes) with glaucoma, who underwent glaucoma surgery and had a stable postoperative mean IOP < 22 mmHg, were enrolled. ...The RNFL thinning was evident for a few months after glaucoma surgery in patients with a higher preoperative

A total of 60 patients (60 eyes) with glaucoma, who underwent glaucoma surgery and had a stable postoperative mean IOP < 22

Thickness of the Macula, Retinal Nerve Fiber Layer, and Ganglion Cell-inner Plexiform Layer in the Macular Hole: The Repeatability Study of Spectral-domain Optical Coherence Tomography.
Lee WH, Jo YJ, Kim JY. Lee WH, et al. Among authors: kim jy. Korean J Ophthalmol. 2018 Dec;32(6):506-516. doi: 10.3341/kjo.2018.0030. Korean J Ophthalmol. 2018. PMID: 30549475 Free PMC article.
The impact of changes in the macular shape caused by macular holes should be taken into consideration when measuring the GCIPL thickness in patients with various eye diseases such as glaucoma and in those with neuro-ophthalmic disorders....
The impact of changes in the macular shape caused by macular holes should be taken into consideration when measuring the GCIPL thickness in …
Effects of Measurement Center Shift on Ganglion Cell-inner Plexiform Layer Thickness Measurements.
Kim KN, Shin IH, Kwak BS, Sung JY, Lim HB, Jo YJ, Kim JY. Kim KN, et al. Among authors: kim jy. Optom Vis Sci. 2018 Aug;95(8):656-662. doi: 10.1097/OPX.0000000000001251. Optom Vis Sci. 2018. PMID: 30063660
CONCLUSIONS: The impact of changes associated with shifting of the measurement center should be taken into consideration when measuring GCIPL thickness in patients with retinal diseases, glaucoma, or neuro-ophthalmological conditions....
CONCLUSIONS: The impact of changes associated with shifting of the measurement center should be taken into consideration when measuring GCIP …
Long-term reproducibility of GC-IPL thickness measurements using spectral domain optical coherence tomography in eyes with high myopia.
Lee MW, Park KS, Lim HB, Jo YJ, Kim JY. Lee MW, et al. Among authors: kim jy. Sci Rep. 2018 Jul 23;8(1):11037. doi: 10.1038/s41598-018-29466-8. Sci Rep. 2018. PMID: 30038425 Free PMC article.
We aimed to analyze the long-term reproducibility of thickness measurements of the GC-IPL using spectral-domain optical coherence tomography (SD-OCT) in patients with high myopia and identify factors that affect such reproducibility. 99 eyes from 99 patients with high myopia with …
We aimed to analyze the long-term reproducibility of thickness measurements of the GC-IPL using spectral-domain optical coherence tomography …
THICKNESSES OF CENTRAL MACULAR, RETINAL NERVE FIBER, AND GANGLION CELL INNER PLEXIFORM LAYERS IN PATIENTS WITH HYPERTENSION.
Lee SH, Lee WH, Lim HB, Jo YJ, Kim JY. Lee SH, et al. Among authors: kim jy. Retina. 2019 Sep;39(9):1810-1818. doi: 10.1097/IAE.0000000000002216. Retina. 2019. PMID: 29757807
Thus, the effects of retinal changes associated with hypertension should be considered when analyzing the thicknesses of the central macular, RNFL, and GCIPL layers in patients with ocular disorders, including retinal, glaucoma, and neuro-ophthalmological diseases....
Thus, the effects of retinal changes associated with hypertension should be considered when analyzing the thicknesses of the central macular …
Changes in Central Macular Thickness and Retinal Nerve Fiber Layer Thickness in Eyes with Vogt-Koyanagi-Harada Disease: A 2-Year Follow-Up Study.
Han YS, Shin KS, Lee WH, Kim JY. Han YS, et al. Among authors: kim jy. Ophthalmologica. 2018;239(2-3):143-150. doi: 10.1159/000481863. Epub 2018 Jan 16. Ophthalmologica. 2018. PMID: 29339644
When diagnosing or monitoring diseases including glaucoma and neuro-ophthalmic diseases that affect the retinal thickness in patients with VKH disease, we recommend considering longitudinal changes in the retinal thickness....
When diagnosing or monitoring diseases including glaucoma and neuro-ophthalmic diseases that affect the retinal thickness in patients …
Changes in thickness of central macula and retinal nerve fibre layer in severe hypertensive retinopathy: a 1-year longitudinal study.
Lee HM, Lee WH, Kim KN, Jo YJ, Kim JY. Lee HM, et al. Among authors: kim jy. Acta Ophthalmol. 2018 May;96(3):e386-e392. doi: 10.1111/aos.13521. Epub 2017 Oct 4. Acta Ophthalmol. 2018. PMID: 28975766 Free article.
Therefore, the impact of retinal changes associated with systemic diseases such as hypertension should be considered in analysing the thicknesses of the RNFL and central macula in ocular disorders, including retina, glaucoma and neuro-ophthalmologic diseases....
Therefore, the impact of retinal changes associated with systemic diseases such as hypertension should be considered in analysing the thickn …
Ganglion Cell-Inner Plexiform Layer Thickness in Retinal Diseases: Repeatability Study of Spectral-Domain Optical Coherence Tomography.
Lee HJ, Kim MS, Jo YJ, Kim JY. Lee HJ, et al. Among authors: kim jy. Am J Ophthalmol. 2015 Aug;160(2):283-289.e1. doi: 10.1016/j.ajo.2015.05.015. Epub 2015 May 21. Am J Ophthalmol. 2015. PMID: 26004405
The impact of changes in macular shape caused by various retinal diseases should be taken into consideration when measuring ganglion cell-inner plexiform layer thickness in other diseases such as glaucoma and neuro-ophthalmology....
The impact of changes in macular shape caused by various retinal diseases should be taken into consideration when measuring ganglion cell-in …
Sectoral retinal nerve fiber layer thinning in branch retinal vein occlusion.
Kim CS, Shin KS, Lee HJ, Jo YJ, Kim JY. Kim CS, et al. Among authors: kim jy. Retina. 2014 Mar;34(3):525-30. doi: 10.1097/IAE.0b013e3182a2e746. Retina. 2014. PMID: 23958844
Retinal nerve fiber layer thinning needs to be differentiated from glaucoma or systemic disease, but it should be considered the natural course after BRVO....
Retinal nerve fiber layer thinning needs to be differentiated from glaucoma or systemic disease, but it should be considered the natu …