Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

125 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
Sparse MRI: The application of compressed sensing for rapid MR imaging.
Lustig M, Donoho D, Pauly JM. Lustig M, et al. Magn Reson Med. 2007 Dec;58(6):1182-95. doi: 10.1002/mrm.21391. Magn Reson Med. 2007. PMID: 17969013
Single breath-hold whole-heart MRA using variable-density spirals at 3T.
Santos JM, Cunningham CH, Lustig M, Hargreaves BA, Hu BS, Nishimura DG, Pauly JM. Santos JM, et al. Among authors: lustig m. Magn Reson Med. 2006 Feb;55(2):371-9. doi: 10.1002/mrm.20765. Magn Reson Med. 2006. PMID: 16408262
Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI.
Hu S, Lustig M, Chen AP, Crane J, Kerr A, Kelley DA, Hurd R, Kurhanewicz J, Nelson SJ, Pauly JM, Vigneron DB. Hu S, et al. Among authors: lustig m. J Magn Reson. 2008 Jun;192(2):258-64. doi: 10.1016/j.jmr.2008.03.003. Epub 2008 Mar 18. J Magn Reson. 2008. PMID: 18367420 Free PMC article.
A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectories.
Lustig M, Kim SJ, Pauly JM. Lustig M, et al. IEEE Trans Med Imaging. 2008 Jun;27(6):866-73. doi: 10.1109/TMI.2008.922699. IEEE Trans Med Imaging. 2008. PMID: 18541493 Free PMC article.
Multiband excitation pulses for hyperpolarized 13C dynamic chemical-shift imaging.
Larson PE, Kerr AB, Chen AP, Lustig MS, Zierhut ML, Hu S, Cunningham CH, Pauly JM, Kurhanewicz J, Vigneron DB. Larson PE, et al. Among authors: lustig ms. J Magn Reson. 2008 Sep;194(1):121-7. doi: 10.1016/j.jmr.2008.06.010. Epub 2008 Jun 24. J Magn Reson. 2008. PMID: 18619875 Free PMC article.
Multiple-profile homogeneous image combination: application to phase-cycled SSFP and multicoil imaging.
Cukur T, Lustig M, Nishimura DG. Cukur T, et al. Among authors: lustig m. Magn Reson Med. 2008 Sep;60(3):732-8. doi: 10.1002/mrm.21720. Magn Reson Med. 2008. PMID: 18727089 Free PMC article.
Anisotropic field-of-view shapes for improved PROPELLER imaging.
Larson PE, Lustig MS, Nishimura DG. Larson PE, et al. Among authors: lustig ms. Magn Reson Imaging. 2009 May;27(4):470-9. doi: 10.1016/j.mri.2008.07.023. Epub 2008 Sep 24. Magn Reson Imaging. 2009. PMID: 18818039 Free PMC article.
Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing.
Cukur T, Lustig M, Nishimura DG. Cukur T, et al. Among authors: lustig m. Magn Reson Med. 2009 May;61(5):1122-31. doi: 10.1002/mrm.21907. Magn Reson Med. 2009. PMID: 19230013 Free PMC article.
Improved shim method based on the minimization of the maximum off-resonance frequency for balanced steady-state free precession (bSSFP).
Lee J, Lustig M, Kim DH, Pauly JM. Lee J, et al. Among authors: lustig m. Magn Reson Med. 2009 Jun;61(6):1500-6. doi: 10.1002/mrm.21800. Magn Reson Med. 2009. PMID: 19319895 Free PMC article.
Time-optimal design for multidimensional and parallel transmit variable-rate selective excitation.
Lee D, Lustig M, Grissom WA, Pauly JM. Lee D, et al. Among authors: lustig m. Magn Reson Med. 2009 Jun;61(6):1471-9. doi: 10.1002/mrm.21950. Magn Reson Med. 2009. PMID: 19365849 Free PMC article.
125 results
Jump to page
Feedback