Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2010 1
2013 1
2016 1
2017 2
2019 1
2020 3
2021 3
2022 3
2023 1
Text availability
Article attribute
Article type
Publication date

Search Results

15 results
Results by year
Filters applied: . Clear all
Page 1
Accuracy of proton magnetic resonance for diagnosing non-alcoholic steatohepatitis: a meta-analysis.
Kim TH, Jeong CW, Jun HY, Lee C, Noh S, Kim JE, Kim S, Yoon KH. Kim TH, et al. Sci Rep. 2019 Oct 18;9(1):15002. doi: 10.1038/s41598-019-51302-w. Sci Rep. 2019. PMID: 31628409 Free PMC article.
Liver biopsy is the reference standard test to differentiate between non-alcoholic steatohepatitis (NASH) and simple steatosis (SS) in non-alcoholic fatty liver disease (NAFLD), but noninvasive diagnostics are warranted. The diagnostic accuracy in NASH using MR imaging mod …
Liver biopsy is the reference standard test to differentiate between non-alcoholic steatohepatitis (NASH) and simple steatosis (SS) in non-a …
Regional Analysis of Liver Surface Nodularity in a Single Axial MR Image for Staging Liver Fibrosis.
Kim TH, Kim YR, Jeong CW, Kim HJ, Kim JW, Lee YH, Yoon KH. Kim TH, et al. J Magn Reson Imaging. 2022 Dec;56(6):1781-1791. doi: 10.1002/jmri.28208. Epub 2022 May 11. J Magn Reson Imaging. 2022. PMID: 35543163 Free PMC article.
PURPOSE: To evaluate the regional analysis of LSN and processing time in a single axial liver MR image for staging liver fibrosis. STUDY TYPE: Retrospective. ...CONCLUSION: Quantitative regional LSN measurement in a single axial MR image reduces processing time. Reg …
PURPOSE: To evaluate the regional analysis of LSN and processing time in a single axial liver MR image for staging liver fibrosis. ST …
Prognostic importance of mitral regurgitation complicated by acute myocardial infarction during a 5-year follow-up period in the drug-eluting stent era.
Kim TH, Lee KY, Choi Y, Park HW, Lee YS, Koh YS, Park HJ, Kim PJ, Chang K, Chung WS, Kim DB, Her SH, Park CS, Lee JM, Kim HY, Yoo KD, Jeon DS, Ahn Y, Jeong MH, Seung KB. Kim TH, et al. Coron Artery Dis. 2016 Mar;27(2):109-15. doi: 10.1097/MCA.0000000000000324. Coron Artery Dis. 2016. PMID: 26626143
The aim of this study was to assess the clinical and angiographic characteristics associated with MR, the incidence and predictors of MR, and the outcomes of MR after AMI in those who were successfully treated with primary percutaneous coronary intervention ( …
The aim of this study was to assess the clinical and angiographic characteristics associated with MR, the incidence and predictors of …
Image-Based Evaluation of Irradiation Effects in Brain Tissues by Measuring Absolute Electrical Conductivity Using MRI.
Kim JW, Park JA, Katoch N, Yang JU, Park S, Choi BK, Song SG, Kim TH, Kim HJ. Kim JW, et al. Cancers (Basel). 2021 Oct 31;13(21):5490. doi: 10.3390/cancers13215490. Cancers (Basel). 2021. PMID: 34771653 Free PMC article.
Image-based evaluation of tissue damage by irradiation has an advantage for the early assessment of therapeutic effects by providing sensitive information on minute tissue responses in situ. Recent magnetic resonance (MR)-based electrical conductivity imaging has shown pot …
Image-based evaluation of tissue damage by irradiation has an advantage for the early assessment of therapeutic effects by providing sensiti …
Development and validation of a management system and dataset quality assessment tool for the Radiology Common Data Model (R_CDM): A case study in liver disease.
Kim TH, Noh S, Kim YR, Lee C, Kim JE, Jeong CW, Yoon KH. Kim TH, et al. Int J Med Inform. 2022 Apr 1;162:104759. doi: 10.1016/j.ijmedinf.2022.104759. Online ahead of print. Int J Med Inform. 2022. PMID: 35390589 Free article.
RESULTS: On a PACS, 368,333,676 DICOM files (1,001,797 cases) were converted to R_CDM chronic liver disease (CLD) data (316,596 MR images, 228 cases; 926,753 CT images, 782 cases) and uploaded to a web-based management system. Acquisition date and resolution were extracted …
RESULTS: On a PACS, 368,333,676 DICOM files (1,001,797 cases) were converted to R_CDM chronic liver disease (CLD) data (316,596 MR im …
Subclinical cardiac perforation by cardiac implantable electronic device leads detected by cardiac computed tomography.
Lim YM, Uhm JS, Kim M, Kim IS, Jin MN, Yu HT, Kim TH, Lee HJ, Kim YJ, Joung B, Pak HN, Lee MH. Lim YM, et al. BMC Cardiovasc Disord. 2021 Jul 19;21(1):346. doi: 10.1186/s12872-021-02159-3. BMC Cardiovasc Disord. 2021. PMID: 34281506 Free PMC article.
There were no significant differences in the incidence of cardiac perforation between atrial and ventricular leads, screw-in and tined atrial leads, pacing and defibrillator ventricular leads, nor between magnetic resonance (MR)-conditional and MR-unsafe screw-in ve …
There were no significant differences in the incidence of cardiac perforation between atrial and ventricular leads, screw-in and tined atria …
Development of quantification software for evaluating body composition contents and its clinical application in sarcopenic obesity.
Kim S, Kim TH, Jeong CW, Lee C, Noh S, Kim JE, Yoon KH. Kim S, et al. Sci Rep. 2020 Jun 26;10(1):10452. doi: 10.1038/s41598-020-67461-0. Sci Rep. 2020. PMID: 32591563 Free PMC article.
This study developed a quantification software for the body composition imaging using abdominal magnetic resonance (MR) images and compared the difference between sarcopenic obesity and healthy controls for clinical application. ...This study developed customized sarcopeni …
This study developed a quantification software for the body composition imaging using abdominal magnetic resonance (MR) images and co …
A mendelian randomization analysis: The causal association between serum uric acid and atrial fibrillation.
Hong M, Park JW, Yang PS, Hwang I, Kim TH, Yu HT, Uhm JS, Joung B, Lee MH, Jee SH, Pak HN. Hong M, et al. Eur J Clin Invest. 2020 Oct;50(10):e13300. doi: 10.1111/eci.13300. Epub 2020 Jun 13. Eur J Clin Invest. 2020. PMID: 32474920
To clarify the potential causal association between UA and AF, we performed a Mendelian randomization (MR) analysis using genetic instrumental variables (IVs). MATERIALS AND METHODS: From the Korean GWAS dataset of 633 patients with AF (mean age 50.6 7.8 years, 80.9% male, …
To clarify the potential causal association between UA and AF, we performed a Mendelian randomization (MR) analysis using genetic ins …
Staging of Liver Fibrosis by Means of Semiautomatic Measurement of Liver Surface Nodularity in MRI.
Kim SW, Kim YR, Choi KH, Cho EY, Song JS, Kim JE, Kim TH, Lee YH, Yoon KH. Kim SW, et al. AJR Am J Roentgenol. 2020 Sep;215(3):624-630. doi: 10.2214/AJR.19.22041. Epub 2020 Jul 1. AJR Am J Roentgenol. 2020. PMID: 32755157
The purposes of this study were to evaluate the accuracy of a semiautomatic method of measuring liver surface nodularity (LSN) on contrast-enhanced MR images and to compare the LSN score with pathologic fibrosis stage. ...The optimal cutoff value for differentiating F0-F2 …
The purposes of this study were to evaluate the accuracy of a semiautomatic method of measuring liver surface nodularity (LSN) on contrast-e …
Assessment of Liver Fibrosis Stage Using Integrative Analysis of Hepatic Heterogeneity and Nodularity in Routine MRI with FIB-4 Index as Reference Standard.
Kim TH, Jeong CW, Kim JE, Kim JW, Jo HG, Kim YR, Lee YH, Yoon KH. Kim TH, et al. J Clin Med. 2021 Apr 15;10(8):1697. doi: 10.3390/jcm10081697. J Clin Med. 2021. PMID: 33920804 Free PMC article.
The combination of L(Het) and L(Nod) scores derived from routine MR images allows better differential diagnosis of fibrosis subgroups in CLD....
The combination of L(Het) and L(Nod) scores derived from routine MR images allows better differential diagnosis of fibrosis subgroups …
15 results