Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

878 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm.
Olsen T, Corydon L, Gimbel H. Olsen T, et al. J Cataract Refract Surg. 1995 May;21(3):313-9. doi: 10.1016/s0886-3350(13)80140-x. J Cataract Refract Surg. 1995. PMID: 7674170
The accuracy of intraocular lens (IOL) power calculation was evaluated in a multicenter study of 822 IOL implantations using the Binkhorst II, Sanders/Retzlaff/Kraff (SRK I, SRK II, SRK/T), Holladay, and Olsen formulas. All but the first of these were optimized in r …
The accuracy of intraocular lens (IOL) power calculation was evaluated in a multicenter study of 822 IOL implantations using the Binkhorst I …
Reply: To PMID 26117311.
Hoffer KJ, Aramberri J, Haigis W, Olsen T, Savini G, Shammas HJ, Bentow S. Hoffer KJ, et al. Among authors: olsen t. Am J Ophthalmol. 2015 Nov;160(5):1086-7. doi: 10.1016/j.ajo.2015.08.011. Epub 2015 Sep 15. Am J Ophthalmol. 2015. PMID: 26385838 No abstract available.
Protocols for studies of intraocular lens formula accuracy.
Hoffer KJ, Aramberri J, Haigis W, Olsen T, Savini G, Shammas HJ, Bentow S. Hoffer KJ, et al. Among authors: olsen t. Am J Ophthalmol. 2015 Sep;160(3):403-405.e1. doi: 10.1016/j.ajo.2015.05.029. Epub 2015 Jun 25. Am J Ophthalmol. 2015. PMID: 26117311 No abstract available.
Precision of 5 different keratometry devices.
Laursen JVN, Jeppesen P, Olsen T. Laursen JVN, et al. Among authors: olsen t. Int Ophthalmol. 2016 Feb;36(1):17-20. doi: 10.1007/s10792-015-0069-3. Epub 2015 Mar 29. Int Ophthalmol. 2016. PMID: 25820577
Use of fellow eye data in the calculation of intraocular lens power for the second eye.
Olsen T. Olsen T. Ophthalmology. 2011 Sep;118(9):1710-5. doi: 10.1016/j.ophtha.2011.04.030. Epub 2011 Jul 2. Ophthalmology. 2011. PMID: 21723613
METHODS: The refractive outcome was analyzed in retrospect and the IOL power calculation was reviewed using 3 different methods: (1) the old Sanders-Retzlaff-Kraff (SRK) II formula, (2) the newer SRK/T formula, and (3) the more recent Olsen formula. In a subgroup of …
METHODS: The refractive outcome was analyzed in retrospect and the IOL power calculation was reviewed using 3 different methods: (1) the old …
C constant: new concept for ray tracing-assisted intraocular lens power calculation.
Olsen T, Hoffmann P. Olsen T, et al. J Cataract Refract Surg. 2014 May;40(5):764-73. doi: 10.1016/j.jcrs.2013.10.037. J Cataract Refract Surg. 2014. PMID: 24767910 Clinical Trial.
Various IOL designs were studied; powers ranged from -5.0 diopters (D) to +38.0 D. The IOL power calculation was performed with the Olsen formula using the C constant and compared with the Haigis, Hoffer Q, Holladay 1, and the SRK/T formulas on optimized datasets. . …
Various IOL designs were studied; powers ranged from -5.0 diopters (D) to +38.0 D. The IOL power calculation was performed with the Olsen
Intraocular lens calculation accuracy limits in normal eyes.
Preussner PR, Olsen T, Hoffmann P, Findl O. Preussner PR, et al. Among authors: olsen t. J Cataract Refract Surg. 2008 May;34(5):802-8. doi: 10.1016/j.jcrs.2008.01.015. J Cataract Refract Surg. 2008. PMID: 18471636
Calculation of intraocular lens power: a review.
Olsen T. Olsen T. Acta Ophthalmol Scand. 2007 Aug;85(5):472-85. doi: 10.1111/j.1600-0420.2007.00879.x. Epub 2007 Apr 2. Acta Ophthalmol Scand. 2007. PMID: 17403024 Free article. Review.
On the ocular refractive components: the Reykjavik Eye Study.
Olsen T, Arnarsson A, Sasaki H, Sasaki K, Jonasson F. Olsen T, et al. Acta Ophthalmol Scand. 2007 Jun;85(4):361-6. doi: 10.1111/j.1600-0420.2006.00847.x. Epub 2007 Feb 7. Acta Ophthalmol Scand. 2007. PMID: 17286626 Free article.
878 results