Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1948 1
1974 1
1975 1
1978 1
1979 1
1980 4
1981 3
1982 3
1983 2
1984 4
1985 7
1986 4
1987 3
1988 4
1989 3
1990 6
1991 3
1992 6
1993 5
1994 6
1995 2
1996 8
1997 9
1998 3
1999 6
2000 6
2001 9
2002 16
2003 9
2004 9
2005 8
2006 10
2007 18
2008 36
2009 27
2010 41
2011 53
2012 41
2013 51
2014 65
2015 40
2016 37
2017 42
2018 27
2019 29
2020 32
Text availability
Article attribute
Article type
Publication date

Search Results

634 results
Results by year
Filters applied: . Clear all
Page 1
Volar Plate Fixation Versus Plaster Immobilization in Acceptably Reduced Extra-Articular Distal Radial Fractures: A Multicenter Randomized Controlled Trial.
Mulders MAM, Walenkamp MMJ, van Dieren S, Goslings JC, Schep NWL; VIPER Trial Collaborators. Mulders MAM, et al. J Bone Joint Surg Am. 2019 May 1;101(9):787-796. doi: 10.2106/JBJS.18.00693. J Bone Joint Surg Am. 2019. PMID: 31045666 Clinical Trial.
We compared the outcomes of open reduction and volar plate fixation with closed reduction and plaster immobilization in adults with an acceptably reduced extra-articular distal radial fracture. ...Open reduction and volar plate fixation should be considered for pati …
We compared the outcomes of open reduction and volar plate fixation with closed reduction and plaster immobilization in adults with a …
Anatomy of the palmar cutaneous branch of the median nerve: A review.
Smith JL, Ebraheim NA. Smith JL, et al. J Orthop. 2019 Jun 5;16(6):576-579. doi: 10.1016/j.jor.2019.06.010. eCollection 2019 Nov-Dec. J Orthop. 2019. PMID: 31660025 Review.
The palmar cutaneous branch of the median nerve (PCBm) supplies afferent innervation to the volar aspect of the hand. It consistently originates from the radial side of the median nerve, travels in relation to the tendons of the palmaris longus and flexor carpi radi …
The palmar cutaneous branch of the median nerve (PCBm) supplies afferent innervation to the volar aspect of the hand. It consi …
Biomechanical Analysis of Palmar Midcarpal Instability and Treatment by Partial Wrist Arthrodesis.
Shiga SA, Werner FW, Garcia-Elias M, Harley BJ. Shiga SA, et al. J Hand Surg Am. 2018 Apr;43(4):331-338.e2. doi: 10.1016/j.jhsa.2017.10.012. Epub 2017 Nov 14. J Hand Surg Am. 2018. PMID: 29146508
RESULTS: Following ligament sectioning, the model we created for palmar midcarpal instability was characterized by significant increases in (1) lunate angular velocity, (2) lunate flexion-extension, and (3) dorsal/volar motion of the capitate during dorsal/volar
RESULTS: Following ligament sectioning, the model we created for palmar midcarpal instability was characterized by significant increa …
The glabrous palmar flap: the new free or reversed pedicled palmar fasciocutaneous flap for volar hand reconstruction.
Orbay JL, Rosen JG, Khouri RK, Indriago I. Orbay JL, et al. Tech Hand Up Extrem Surg. 2009 Sep;13(3):145-50. doi: 10.1097/BTH.0b013e3181ac9183. Tech Hand Up Extrem Surg. 2009. PMID: 19730044
We devised a new flap using the palmar cutaneous branch of the superficial radial artery proximally and anastomosed with a cutaneous perforator of the superficial palmar arch distally. We named our flap "the volar glabrous palmar flap." The flap was us …
We devised a new flap using the palmar cutaneous branch of the superficial radial artery proximally and anastomosed with a cutaneous …
Iatrogenic Injuries of the Palmar Branch of the Median Nerve Following Volar Plate Fixation of the Distal Radius.
Samson D, Power DM. Samson D, et al. J Hand Surg Asian Pac Vol. 2017 Sep;22(3):343-349. doi: 10.1142/S021881041750040X. J Hand Surg Asian Pac Vol. 2017. PMID: 28774246
BACKGROUND: Our aims were to identify iatrogenous injuries to the palmar branch of the median nerve sustained during volar plate fixation of the distal radius, make the clinician aware of this relatively uncommon complication of distal radius fixation, to emphasise …
BACKGROUND: Our aims were to identify iatrogenous injuries to the palmar branch of the median nerve sustained during volar pla …
Carpal instability nondissociative.
Wolfe SW, Garcia-Elias M, Kitay A. Wolfe SW, et al. J Am Acad Orthop Surg. 2012 Sep;20(9):575-85. doi: 10.5435/JAAOS-20-09-575. J Am Acad Orthop Surg. 2012. PMID: 22941800 Review.
There are four major subcategories of CIND: palmar, dorsal, combined, and adaptive. In palmar CIND, instability occurs across the entire proximal carpal row. ...Treatment of choice is a corrective osteotomy to restore the normal volar tilt of the distal radiu …
There are four major subcategories of CIND: palmar, dorsal, combined, and adaptive. In palmar CIND, instability occurs across …
Volar Central Portal in Wrist Arthroscopy.
Corella F, Ocampos M, Cerro MD, Larrainzar-Garijo R, Vázquez T. Corella F, et al. J Wrist Surg. 2016 Mar;5(1):80-90. doi: 10.1055/s-0035-1570741. Epub 2016 Jan 15. J Wrist Surg. 2016. PMID: 26855842 Free PMC article.
Results The median (interquartile range [IQR]) distances from the volar central radiocarpal portal to the median nerve, palmar cutaneous branch of the median nerve, and ulnar neurovascular bundle were 10.5 (7.8-15.0), 18.5 (15.8-20.3), and 7.0 (5.0-10.5) mm, respect …
Results The median (interquartile range [IQR]) distances from the volar central radiocarpal portal to the median nerve, palmar
Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study.
Sato K, Kikuchi Y, Mimata Y, Murakami K, Takahashi G, Doita M. Sato K, et al. J Orthop Traumatol. 2019 Aug 20;20(1):29. doi: 10.1186/s10195-019-0536-0. J Orthop Traumatol. 2019. PMID: 31432281 Free PMC article.
BACKGROUND: Plate protrusion is a risk factor for flexor pollicis longus (FPL) rupture following volar locking plate (VLP) surgery. ...We evaluated plate prominence from the volar ridge according to the Soong grading system. RESULTS: Soong grades 0 (plate did not ex …
BACKGROUND: Plate protrusion is a risk factor for flexor pollicis longus (FPL) rupture following volar locking plate (VLP) surgery. . …
Volar Midcarpal Portals in Wrist Arthroscopy.
Gillis JA, Kakar S. Gillis JA, et al. J Hand Surg Am. 2019 Dec;44(12):1094.e1-1094.e6. doi: 10.1016/j.jhsa.2019.02.006. Epub 2019 Mar 20. J Hand Surg Am. 2019. PMID: 30902356
Volar ulnar midcarpal (VUMC) and volar radial midcarpal (VRMC) portals were placed using an inside-out technique. The distance between these portals to surrounding anatomical structures was measured in millimeters using a caliper. ...It was an average of 1.0 and 1.9
Volar ulnar midcarpal (VUMC) and volar radial midcarpal (VRMC) portals were placed using an inside-out technique. The distance
Comparison of volar-flexion, ulnar-deviation and functional position cast immobilization in the non-operative treatment of distal radius fracture in elderly patients: a pragmatic randomized controlled trial study protocol.
Raittio L, Launonen A, Hevonkorpi T, Luokkala T, Kukkonen J, Reito A, Sumrein B, Laitinen M, Mattila VM. Raittio L, et al. BMC Musculoskelet Disord. 2017 Sep 18;18(1):401. doi: 10.1186/s12891-017-1759-y. BMC Musculoskelet Disord. 2017. PMID: 28923035 Free PMC article. Clinical Trial.
The trial is designed to compare two widely used cast positions (volar flexion-ulnar deviation position and functional position) for the non-operative treatment of DRF in patients over 64 years of age. The main hypothesis of the trial is that function position yields corre …
The trial is designed to compare two widely used cast positions (volar flexion-ulnar deviation position and functional position) for …
634 results
Jump to page
Feedback