Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

167 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
Measurement of total and compartmental lung volume changes in newborns by optoelectronic plethysmography.
Dellaca' RL, Ventura ML, Zannin E, Natile M, Pedotti A, Tagliabue P. Dellaca' RL, et al. Among authors: pedotti a. Pediatr Res. 2010 Jan;67(1):11-6. doi: 10.1203/PDR.0b013e3181c0b184. Pediatr Res. 2010. PMID: 19755932
Airway opening flow was measured by applying a facemask connected to a pneumotachograph (PNT) and integrated to provide the DeltaVL. ...A total of 771 breaths from all patients were considered. Bland-Altmann analysis showed a mean difference of -0.08 m …
Airway opening flow was measured by applying a facemask connected to a pneumotachograph (PNT) and integrated to provide the De …
Methodological and technological implications of quantitative human movement analysis in long term space flights.
Ferrigno G, Baroni G, Pedotti A. Ferrigno G, et al. Among authors: pedotti a. J Biomech. 1999 Apr;32(4):431-6. doi: 10.1016/s0021-9290(98)00175-4. J Biomech. 1999. PMID: 10213034
For this aim, a space qualified opto-electronic motion analyser based on passive markers was installed onboard the MIR Space Station. ...An optimisation method for the recovering of a unique reference frame throughout the whole mission is described. Results highligh …
For this aim, a space qualified opto-electronic motion analyser based on passive markers was installed onboard the MIR Space Station. …
Opto-electronic plethysmography.
Aliverti A, Pedotti A. Aliverti A, et al. Among authors: pedotti a. Monaldi Arch Chest Dis. 2003 Jan-Mar;59(1):12-6. Monaldi Arch Chest Dis. 2003. PMID: 14533277
Recent developments of Opto-Electronic plethysmography allow a noninvasive and accurate measurement of the volume of the chest wall and its different thoraco-abdominal compartments, without any calibration specific on the subject under analysis. ...
Recent developments of Opto-Electronic plethysmography allow a noninvasive and accurate measurement of the volume of the chest wall a …
Spatial distribution of human respiratory system transfer impedance.
Dellacà RL, Aliverti A, Lutchen KR, Pedotti A. Dellacà RL, et al. Among authors: pedotti a. Ann Biomed Eng. 2003 Feb;31(2):121-31. doi: 10.1114/1.1541012. Ann Biomed Eng. 2003. PMID: 12627819 Clinical Trial.
To study Ztr distribution on the chest wall surface we analyzed five healthy subjects in the supine position by applying a sinusoidal forcing pressure (4, 8, and 12 Hz) at the mouth and measuring airway opening pressure and flow. ...We used a new method to measure t …
To study Ztr distribution on the chest wall surface we analyzed five healthy subjects in the supine position by applying a sinusoidal …
Relationship between respiratory impedance and positive end-expiratory pressure in mechanically ventilated neonates.
Dellacà RL, Veneroni C, Vendettuoli V, Zannin E, Matassa PG, Pedotti A, Colnaghi M, Mosca F. Dellacà RL, et al. Among authors: pedotti a. Intensive Care Med. 2013 Mar;39(3):511-9. doi: 10.1007/s00134-012-2795-6. Epub 2013 Jan 11. Intensive Care Med. 2013. PMID: 23306585
Positional effects on lung mechanics of ventilated preterm infants with acute and chronic lung disease.
Vendettuoli V, Veneroni C, Zannin E, Mercadante D, Matassa P, Pedotti A, Colnaghi M, Dellacà RL, Mosca F. Vendettuoli V, et al. Among authors: pedotti a. Pediatr Pulmonol. 2015 Aug;50(8):798-804. doi: 10.1002/ppul.23049. Epub 2014 Apr 7. Pediatr Pulmonol. 2015. PMID: 24706414
Estimation of end-expiratory lung volume variations by optoelectronic plethysmography.
Dellacà RL, Aliverti A, Pelosi P, Carlesso E, Chiumello D, Pedotti A, Gattinoni L. Dellacà RL, et al. Among authors: pedotti a. Crit Care Med. 2001 Sep;29(9):1807-11. doi: 10.1097/00003246-200109000-00026. Crit Care Med. 2001. PMID: 11546992
MEASUREMENTS AND MAIN RESULTS: In the model protocol, we tested the reproducibility of the OEP by repeating volume measurements of a plastic torso model over a 21-hr period, every 30 mins. ...Furthermore, OEP allows a continuous compartmental analysis, even d …
MEASUREMENTS AND MAIN RESULTS: In the model protocol, we tested the reproducibility of the OEP by repeating volume measurements of a
Real-time opto-electronic verification of patient position in breast cancer radiotherapy.
Baroni G, Ferrigno G, Orecchia R, Pedotti A. Baroni G, et al. Among authors: pedotti a. Comput Aided Surg. 2000;5(4):296-306. doi: 10.1002/1097-0150(2000)5:4<296::AID-IGS8>3.0.CO;2-I. Comput Aided Surg. 2000. PMID: 11029162 Clinical Trial.
This feature ensures a high accuracy, even with small marker dimensions, and successful analysis in a noisy environment (due to room light, reflexes, etc.). The patient repositioning control was based on a comparison between the current positions of the marke …
This feature ensures a high accuracy, even with small marker dimensions, and successful analysis in a noisy environment (due t …
[Optoelectronic plethysmography: a new tool in respiratory medicine].
Aliverti A, Dellacà R, Pedotti A. Aliverti A, et al. Among authors: pedotti a. Recenti Prog Med. 2001 Nov;92(11):644-7. Recenti Prog Med. 2001. PMID: 11765654 Italian.
Opto-electronic plethysmography (OEP) is a new noninvasive technique, recently introduced, which is highly accurate in the measurement of total chest wall volume variations, allowing partitioning of the complex shape of the chest wall into different functional compartments …
Opto-electronic plethysmography (OEP) is a new noninvasive technique, recently introduced, which is highly accurate in the measuremen …
Optoelectronic plethysmography in intensive care patients.
Aliverti A, Dellacá R, Pelosi P, Chiumello D, Pedotti A, Gattinoni L. Aliverti A, et al. Among authors: pedotti a. Am J Respir Crit Care Med. 2000 May;161(5):1546-52. doi: 10.1164/ajrccm.161.5.9903024. Am J Respir Crit Care Med. 2000. PMID: 10806152
We conclude that optoelectronic plethysmography is a feasible technique able to provide unique data on the distribution of chest wall volume changes in intensive care patients....
We conclude that optoelectronic plethysmography is a feasible technique able to provide unique data on the distribution of chest wall …
167 results
Jump to page
Feedback