Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2010 2
2011 1
2013 1
2021 0
Text availability
Article attribute
Article type
Publication date

Search Results

3 results
Results by year

Citations

1 article found by citation matching

Search results

Filters applied: . Clear all
Page 1
Performance of an automated polysomnography scoring system versus computer-assisted manual scoring.
Malhotra A, Younes M, Kuna ST, Benca R, Kushida CA, Walsh J, Hanlon A, Staley B, Pack AI, Pien GW. Malhotra A, et al. Sleep. 2013 Apr 1;36(4):573-82. doi: 10.5665/sleep.2548. Sleep. 2013. PMID: 23565003 Free PMC article.
The purpose of this study was to compare a new automated scoring system (YST-Limited, Winnipeg, Canada) with computer-assisted manual scoring. ...Intraclass correlation coefficient (ICC) was obtained for the 70 pairs and compared t …
The purpose of this study was to compare a new automated scoring system (YST-Limited, Winnipeg, Canada) with compute
Comparison of the automatic analysis versus the manual scoring from ApneaLink device for the diagnosis of obstructive sleep apnoea syndrome.
Nigro CA, Dibur E, Aimaretti S, González S, Rhodius E. Nigro CA, et al. Sleep Breath. 2011 Dec;15(4):679-86. doi: 10.1007/s11325-010-0421-9. Epub 2010 Oct 3. Sleep Breath. 2011. PMID: 20890768
OBJECTIVE: The purpose of this study was to compare the performance of the automated detection versus the manual scoring from the ApneaLink device to diagnose obstructive sleep apnoea syndrome (OSAS). ...The ApneaLink manual scoring
OBJECTIVE: The purpose of this study was to compare the performance of the automated detection versus the manual
Automatic sleep scoring in normals and in individuals with neurodegenerative disorders according to new international sleep scoring criteria.
Jensen PS, Sorensen HB, Leonthin HL, Jennum P. Jensen PS, et al. J Clin Neurophysiol. 2010 Aug;27(4):296-302. doi: 10.1097/WNP.0b013e3181eaad4b. J Clin Neurophysiol. 2010. PMID: 20634706
This led to quantification of automatic versus manual epoch-by-epoch agreement rates for both normals and abnormals. ...Based on an observed reliability of the manual scorer of 92.5% (Cohen's Kappa: 0.87) in the normal group and 85.3% (Cohen's K …
This led to quantification of automatic versus manual epoch-by-epoch agreement rates for both normals and abnormals. ...Based …