Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

321 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
Prognostic value of the pattern electroretinogram in cases of tumors affecting the optic pathway.
Rüther K, Ehlich P, Philipp A, Eckstein A, Zrenner E. Rüther K, et al. Graefes Arch Clin Exp Ophthalmol. 1998 Apr;236(4):259-63. doi: 10.1007/s004170050074. Graefes Arch Clin Exp Ophthalmol. 1998. PMID: 9561357
RESULTS: Using patterns of 1.5 x 1.2 deg there was a good correlation between the change of pre- and post-surgical visual performance and most of the pattern ERG amplitudes. For all variables tested--P50, N95- and steady-state amplitude--there was a critical value b …
RESULTS: Using patterns of 1.5 x 1.2 deg there was a good correlation between the change of pre- and post-surgical visual performance …
Heparin-coated equipment reduces the risk of oxygenator failure.
Wahba A, Philipp A, Behr R, Birnbaum DE. Wahba A, et al. Ann Thorac Surg. 1998 May;65(5):1310-2. doi: 10.1016/s0003-4975(98)00156-8. Ann Thorac Surg. 1998. PMID: 9594857
A range of membrane oxygenators was used subject to availability; 769 oxygenators were heparin-coated and 1,190 were uncoated. ...CONCLUSIONS: We conclude that a heparin-coated oxygenator effectively prevents APG. This adds significantly to the safety of open heart
A range of membrane oxygenators was used subject to availability; 769 oxygenators were heparin-coated and 1,190 were uncoated. ...CON
Bridge to lung transplantation through a pulmonary artery to left atrial oxygenator circuit.
Schmid C, Philipp A, Hilker M, Arlt M, Trabold B, Pfeiffer M, Schmid FX. Schmid C, et al. Ann Thorac Surg. 2008 Apr;85(4):1202-5. doi: 10.1016/j.athoracsur.2007.12.032. Ann Thorac Surg. 2008. PMID: 18355495
METHODS: In a 38-year-old female patient with primary pulmonary hypertension a paracorporeal artificial lung (PAL) system was placed parallel to the pulmonary circulation with connections to the pulmonary artery and to the left atrium. The key component of the PAL w …
METHODS: In a 38-year-old female patient with primary pulmonary hypertension a paracorporeal artificial lung (PAL) system was …
Emergency and prophylactic use of miniaturized veno-arterial extracorporeal membrane oxygenation in transcatheter aortic valve implantation.
Husser O, Holzamer A, Philipp A, Nunez J, Bodi V, Müller T, Lubnow M, Luchner A, Lunz D, Riegger GA, Schmid C, Hengstenberg C, Hilker M. Husser O, et al. Catheter Cardiovasc Interv. 2013 Oct 1;82(4):E542-51. doi: 10.1002/ccd.24806. Epub 2013 Apr 29. Catheter Cardiovasc Interv. 2013. PMID: 23554044 Clinical Trial.
Interhospital transportation of patients with severe lung failure on pumpless extracorporeal lung assist.
Zimmermann M, Bein T, Philipp A, Ittner K, Foltan M, Drescher J, Weber F, Schmid FX. Zimmermann M, et al. Br J Anaesth. 2006 Jan;96(1):63-6. doi: 10.1093/bja/aei274. Epub 2005 Nov 18. Br J Anaesth. 2006. PMID: 16299045
BACKGROUND: To describe the use of pumpless extracorporeal interventional lung assist (iLA) for transportation of patients with severe life-threatening acute lung failure from tertiary hospitals to a specialized centre. ...RESULTS: After implementation of iLA, a rap …
BACKGROUND: To describe the use of pumpless extracorporeal interventional lung assist (iLA) for transportation of patients with severe life- …
Extracorporeal lung support in trauma patients with severe chest injury and acute lung failure: a 10-year institutional experience.
Ried M, Bein T, Philipp A, Müller T, Graf B, Schmid C, Zonies D, Diez C, Hofmann HS. Ried M, et al. Crit Care. 2013 Jun 20;17(3):R110. doi: 10.1186/cc12782. Crit Care. 2013. PMID: 23786965 Free PMC article. Clinical Trial.
METHODS: A retrospective, observational analysis of prospectively collected data (Regensburg ECMO Registry database) was performed for all consecutive trauma patients with acute pulmonary failure requiring ELS during a 10-year interval. ...
METHODS: A retrospective, observational analysis of prospectively collected data (Regensburg ECMO Registry database) was performed fo …
In vivo uptake and elimination of isoflurane by different membrane oxygenators during cardiopulmonary bypass.
Wiesenack C, Wiesner G, Keyl C, Gruber M, Philipp A, Ritzka M, Prasser C, Taeger K. Wiesenack C, et al. Anesthesiology. 2002 Jul;97(1):133-8. doi: 10.1097/00000542-200207000-00019. Anesthesiology. 2002. PMID: 12131114 Clinical Trial.
This study was designed to evaluate whether the in vivo uptake and elimination of isoflurane differs between microporous membrane oxygenators containing a conventional polypropylene (PPL) membrane and oxygenators with a new poly-(4-methyl-1-pentene) (PMP) membrane m …
This study was designed to evaluate whether the in vivo uptake and elimination of isoflurane differs between microporous membrane oxygenator …
Extracorporeal membrane oxygenation: evolving epidemiology and mortality.
Karagiannidis C, Brodie D, Strassmann S, Stoelben E, Philipp A, Bein T, Müller T, Windisch W. Karagiannidis C, et al. Intensive Care Med. 2016 May;42(5):889-896. doi: 10.1007/s00134-016-4273-z. Epub 2016 Mar 4. Intensive Care Med. 2016. PMID: 26942446
RESULTS: The incidence of vv-ECMO and va-ECMO in the population increased threefold from 1.0:100,000 inhabitants/year in 2007 to a maximum of 3.0:100,000 in 2012, and from 0.1:100,000 in 2007 to 0.7:100,000 in 2012 and to a maximum of 3.5:100,000 in 2014, respective …
RESULTS: The incidence of vv-ECMO and va-ECMO in the population increased threefold from 1.0:100,000 inhabitants/year in 2007 to a ma …
Paracorporeal artificial lung circuit as a possibility for bridge to lung transplantation.
Puehler T, Philipp A, Schmid C. Puehler T, et al. Ann Thorac Surg. 2009 Jul;88(1):352; author reply 352-3. doi: 10.1016/j.athoracsur.2008.12.013. Ann Thorac Surg. 2009. PMID: 19559275 No abstract available.
321 results
Jump to page
Feedback