Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

89 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
Three-dimensional, time-resolved, intrafraction motion monitoring throughout stereotactic liver radiation therapy on a conventional linear accelerator.
Worm ES, Høyer M, Fledelius W, Poulsen PR. Worm ES, et al. Among authors: poulsen pr. Int J Radiat Oncol Biol Phys. 2013 May 1;86(1):190-7. doi: 10.1016/j.ijrobp.2012.12.017. Epub 2013 Feb 12. Int J Radiat Oncol Biol Phys. 2013. PMID: 23414764
First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking.
Cho B, Poulsen PR, Sloutsky A, Sawant A, Keall PJ. Cho B, et al. Among authors: poulsen pr. Int J Radiat Oncol Biol Phys. 2009 Jul 1;74(3):859-67. doi: 10.1016/j.ijrobp.2009.02.012. Int J Radiat Oncol Biol Phys. 2009. PMID: 19480969 Free PMC article.
Dynamic MLC tracking of moving targets with a single kV imager for 3D conformal and IMRT treatments.
Poulsen PR, Cho B, Sawant A, Ruan D, Keall PJ. Poulsen PR, et al. Acta Oncol. 2010 Oct;49(7):1092-100. doi: 10.3109/0284186X.2010.498438. Acta Oncol. 2010. PMID: 20831501
Megavoltage image-based dynamic multileaf collimator tracking of a NiTi stent in porcine lungs on a linear accelerator.
Poulsen PR, Carl J, Nielsen J, Nielsen MS, Thomsen JB, Jensen HK, Kjærgaard B, Zepernick PR, Worm E, Fledelius W, Cho B, Sawant A, Ruan D, Keall PJ. Poulsen PR, et al. Int J Radiat Oncol Biol Phys. 2012 Feb 1;82(2):e321-7. doi: 10.1016/j.ijrobp.2011.03.023. Epub 2011 May 24. Int J Radiat Oncol Biol Phys. 2012. PMID: 21605944 Free PMC article.
Clinical validation of a 4D-CT based method for lung ventilation measurement in phantoms and patients.
Nyeng TB, Kallehauge JF, Høyer M, Petersen JB, Poulsen PR, Muren LP. Nyeng TB, et al. Among authors: poulsen pr. Acta Oncol. 2011 Aug;50(6):897-907. doi: 10.3109/0284186X.2011.577096. Acta Oncol. 2011. PMID: 21767190
Geometric accuracy of dynamic MLC tracking with an implantable wired electromagnetic transponder.
Ravkilde T, Keall PJ, Højbjerre K, Fledelius W, Worm E, Poulsen PR. Ravkilde T, et al. Among authors: poulsen pr. Acta Oncol. 2011 Aug;50(6):944-51. doi: 10.3109/0284186X.2011.590524. Acta Oncol. 2011. PMID: 21767195
Tracking latency in image-based dynamic MLC tracking with direct image access.
Fledelius W, Keall PJ, Cho B, Yang X, Morf D, Scheib S, Poulsen PR. Fledelius W, et al. Among authors: poulsen pr. Acta Oncol. 2011 Aug;50(6):952-9. doi: 10.3109/0284186X.2011.581693. Acta Oncol. 2011. PMID: 21767196
Robust automatic segmentation of multiple implanted cylindrical gold fiducial markers in cone-beam CT projections.
Fledelius W, Worm E, Elstrøm UV, Petersen JB, Grau C, Høyer M, Poulsen PR. Fledelius W, et al. Among authors: poulsen pr. Med Phys. 2011 Dec;38(12):6351-61. doi: 10.1118/1.3658566. Med Phys. 2011. PMID: 22149818
On-line use of three-dimensional marker trajectory estimation from cone-beam computed tomography projections for precise setup in radiotherapy for targets with respiratory motion.
Worm ES, Høyer M, Fledelius W, Nielsen JE, Larsen LP, Poulsen PR. Worm ES, et al. Among authors: poulsen pr. Int J Radiat Oncol Biol Phys. 2012 May 1;83(1):e145-51. doi: 10.1016/j.ijrobp.2011.12.007. Int J Radiat Oncol Biol Phys. 2012. PMID: 22516384
Kilovoltage intrafraction monitoring for prostate intensity modulated arc therapy: first clinical results.
Ng JA, Booth JT, Poulsen PR, Fledelius W, Worm ES, Eade T, Hegi F, Kneebone A, Kuncic Z, Keall PJ. Ng JA, et al. Among authors: poulsen pr. Int J Radiat Oncol Biol Phys. 2012 Dec 1;84(5):e655-61. doi: 10.1016/j.ijrobp.2012.07.2367. Epub 2012 Sep 11. Int J Radiat Oncol Biol Phys. 2012. PMID: 22975613 Free PMC article.
89 results
You have reached the last page of results. A maximum of 10,000 results are available.
Jump to page
Feedback