Abstract

Background: Endobronchial path selection is important for the bronchoscopic diagnosis of focal lung lesions. Path selection typically involves mentally reconstructing a three-dimensional path by interpreting a stack of two-dimensional (2D) axial plane CT scan sections. The hypotheses of our study about path selection were as follows: (1) bronchoscopists are inaccurate and overly confident when making endobronchial path selections based on 2D CT scan analysis; and (2) path selection accuracy and confidence improve and become better aligned when bronchoscopists employ path-planning methods based on virtual bronchoscopy (VB).

Methods: Studies of endobronchial path selection comparing three path-planning methods (ie, the standard 2D CT scan analysis and two new VB-based techniques) were performed. The task was to navigate to discrete lesions located between the third-order and fifth-order bronchi of the right upper and middle lobes. Outcome measures were the cumulative accuracy of making four sequential path selection decisions and self-reported confidence (1, least confident; 5, most confident). Both experienced and inexperienced bronchoscopists participated in the studies.

Results: In the first study involving a static paper-based tool, the mean (+/- SD) cumulative accuracy was 14 +/- 3% using 2D CT scan analysis (confidence, 3.4 +/- 1.3) and 49 +/- 15% using a VB-based technique (confidence, 4.2 +/- 1.1; p = 0.0001 across all comparisons). For a second study using an interactive computer-based tool, the mean accuracy was 40 +/- 28% using 2D CT scan analysis (confidence, 3.0 +/- 0.3) and 96 +/- 3% using a dynamic VB-based technique (confidence, 4.6 +/- 0.2). Regardless of the experience level of the bronchoscopist, use of the standard 2D CT scan analysis resulted in poor path selection accuracy and misaligned confidence. Use of the VB-based techniques resulted in considerably higher accuracy and better aligned decision confidence.

Conclusions: Endobronchial path selection is a source of error in the bronchoscopy workflow. The use of VB-based path-planning techniques significantly improves path selection accuracy over use of the standard 2D CT scan section analysis in this simulation format.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Bronchi / pathology*
  • Bronchography
  • Bronchoscopy / methods*
  • Computer Simulation*
  • Humans
  • Imaging, Three-Dimensional
  • Lung Neoplasms / diagnostic imaging
  • Lung Neoplasms / pathology
  • Observer Variation*
  • Software
  • Tomography, X-Ray Computed
  • User-Computer Interface