Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1963 1
1966 1
2006 1
2007 1
2012 1
2014 1
2016 1
2017 1
2018 2
2019 1
2020 2
2023 0

Text availability

Article attribute

Article type

Publication date

Search Results

11 results

Results by year

Filters applied: . Clear all
Page 1
Derivation of an uncertainty propagation factor for half-life determinations.
Pommé S, De Hauwere T. Pommé S, et al. Appl Radiat Isot. 2020 Apr;158:109046. doi: 10.1016/j.apradiso.2020.109046. Epub 2020 Jan 20. Appl Radiat Isot. 2020. PMID: 32174372 Free article.
It is used as a benchmark to verify the applicability of Parker's solution to non-equidistant data with unequal uncertainties....
It is used as a benchmark to verify the applicability of Parker's solution to non-equidistant data with unequal uncertainties....
Half-life determination and comparison of activity standards of 231Pa.
Jerome S, Bobin C, Cassette P, Dersch R, Galea R, Liu H, Honig A, Keightley J, Kossert K, Liang J, Marouli M, Michotte C, Pommé S, Röttger S, Williams R, Zhang M. Jerome S, et al. Among authors: pomme s. Appl Radiat Isot. 2020 Jan;155:108837. doi: 10.1016/j.apradiso.2019.108837. Epub 2019 Sep 12. Appl Radiat Isot. 2020. PMID: 31655349
Evidence against solar influence on nuclear decay constants.
Pommé S, Stroh H, Paepen J, Van Ammel R, Marouli M, Altzitzoglou T, Hult M, Kossert K, Nähle O, Schrader H, Juget F, Bailat C, Nedjadi Y, Bochud F, Buchillier T, Michotte C, Courte S, van Rooy MW, van Staden MJ, Lubbe J, Simpson BR, Fazio A, De Felice P, Jackson TW, Van Wyngaardt WM, Reinhard MI, Golya J, Bourke S, Roy T, Galea R, Keightley JD, Ferreira KM, Collins SM, Ceccatelli A, Unterweger M, Fitzgerald R, Bergeron DE, Pibida L, Verheyen L, Bruggeman M, Vodenik B, Korun M, Chisté V, Amiot MN. Pommé S, et al. Phys Lett B. 2016 Oct;761:281-286. doi: 10.1016/j.physletb.2016.08.038. Epub 2016 Aug 24. Phys Lett B. 2016. PMID: 28057978 Free PMC article.
The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% to 0.008% to the amplitude of annual oscillations in the decay rate. Oscillations in phase with Earth's orbital distance to the Sun co …
The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% t …
Uncertainty propagation in nuclear forensics.
Pommé S, Jerome SM, Venchiarutti C. Pommé S, et al. Appl Radiat Isot. 2014 Jul;89:58-64. doi: 10.1016/j.apradiso.2014.02.005. Epub 2014 Feb 14. Appl Radiat Isot. 2014. PMID: 24607529 Free article.
The age of radioactive material in this context refers to the time elapsed since a particular radionuclide was chemically separated from its decay product(s). The decay of the parent radionuclide and ingrowth of the daughter nuclide are governed by statistical decay laws. …
The age of radioactive material in this context refers to the time elapsed since a particular radionuclide was chemically separated from its …
Linearity check of an ionisation chamber through 99 mTc half-life measurements.
Pommé S, Paepen J, Van Ammel R. Pommé S, et al. Appl Radiat Isot. 2018 Oct;140:171-178. doi: 10.1016/j.apradiso.2018.07.004. Epub 2018 Jul 6. Appl Radiat Isot. 2018. PMID: 30029094 Free article.
The result, T(1/2)((99 m)Tc) = 6.00660 (18) h, is in good agreement with literature data. One experiment was performed in IC1's default set-up with the ionisation current being integrated over an air capacitor and read out as a voltage increase over time. ...
The result, T(1/2)((99 m)Tc) = 6.00660 (18) h, is in good agreement with literature data. One experiment was performed in IC1's defau …
Advancements in NORM metrology - Results and impact of the European joint research project MetroNORM.
Josef Maringer F, Baumgartner A, Cardellini F, Cassette P, Crespo T, Dean J, Wiedner H, Hůlka J, Hult M, Jerome S, Kabrt F, Kovář P, Larijani C, Lutter G, Marouli M, Mauring A, Mazánová M, Michalik B, Michielsen N, Peyres V, Pierre S, Pöllänen R, Pommé S, Reis M, Stietka M, Szücs L, Vodenik B. Josef Maringer F, et al. Among authors: pomme s. Appl Radiat Isot. 2017 Aug;126:273-278. doi: 10.1016/j.apradiso.2017.02.040. Epub 2017 Mar 8. Appl Radiat Isot. 2017. PMID: 28314506
The results of the three years European Metrology Research Programme's (EMRP) joint research project 'Metrology for processing materials with high natural radioactivity' (MetroNORM) are presented. ...
The results of the three years European Metrology Research Programme's (EMRP) joint research project 'Metrology for processing materi …
The solid angle subtended by a circular detector for a linear source.
Pommé S. Pommé S. Appl Radiat Isot. 2007 Jun;65(6):724-7. doi: 10.1016/j.apradiso.2006.08.003. Epub 2006 Oct 13. Appl Radiat Isot. 2007. PMID: 17049257
An exact solution is presented for the solid angle subtended by a circular detector for a linear source. It is based on Conway's equation for a non-coaxial point source, involving an integral of Bessel functions [Conway, J.T., 2006. Generalizations of Ruby's formula …
An exact solution is presented for the solid angle subtended by a circular detector for a linear source. It is based on Conway's equa …
Measurement of the 226Th and 222Ra half-lives.
Pommé S, Suliman G, Marouli M, Van Ammel R, Jobbágy V, Paepen J, Stroh H, Apostolidis C, Abbas K, Morgenstern A. Pommé S, et al. Appl Radiat Isot. 2012 Sep;70(9):1913-8. doi: 10.1016/j.apradiso.2012.02.117. Epub 2012 Mar 7. Appl Radiat Isot. 2012. PMID: 22445397
The observed half-life values are T(1/2)((226)Th)=30.70 (3) min and T(1/2)((222)Ra)=33.6 (4) s. Literature values show some inconsistency....
The observed half-life values are T(1/2)((226)Th)=30.70 (3) min and T(1/2)((222)Ra)=33.6 (4) s. Literature values show some inconsist …
11 results