Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1982 1
1999 1
2001 1
2012 1
2024 1
2025 0

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

5 results

Results by year

Filters applied: . Clear all
Page 1
Intensity modulated proton therapy: a clinical example.
Lomax AJ, Boehringer T, Coray A, Egger E, Goitein G, Grossmann M, Juelke P, Lin S, Pedroni E, Rohrer B, Roser W, Rossi B, Siegenthaler B, Stadelmann O, Stauble H, Vetter C, Wisser L. Lomax AJ, et al. Among authors: goitein g. Med Phys. 2001 Mar;28(3):317-24. doi: 10.1118/1.1350587. Med Phys. 2001. PMID: 11318312
Over the course of the treatment, a setup accuracy of +/-4 mm (2 s.d.) could be achieved, with a mean offset in the AP direction of 0.1 mm. Inhalation/exhalation CT scans indicated that organ motion in the region of the target volume was negligible. ...
Over the course of the treatment, a setup accuracy of +/-4 mm (2 s.d.) could be achieved, with a mean offset in the AP directi …
Precise positioning of patients for radiation therapy.
Verhey LJ, Goitein M, McNulty P, Munzenrider JE, Suit HD. Verhey LJ, et al. Among authors: goitein m. Int J Radiat Oncol Biol Phys. 1982 Feb;8(2):289-94. doi: 10.1016/0360-3016(82)90530-2. Int J Radiat Oncol Biol Phys. 1982. PMID: 6282792
Patients immobilized in the seated position with a bite block and a mask have a mean movement of about 0.5 mm +/- 0.3 mm (s.d.), and patients immobilized in the supine position with their necks hyperextended for submental therapy evidence a mean movement of about 1. …
Patients immobilized in the seated position with a bite block and a mask have a mean movement of about 0.5 mm +/- 0.3 mm (s.d. …
Verification of the alignment of a therapeutic radiation beam relative to its patient positioner.
Barkhof J, Schut G, Flanz JB, Goitein M, Schippers JM. Barkhof J, et al. Among authors: goitein m. Med Phys. 1999 Nov;26(11):2429-37. doi: 10.1118/1.598761. Med Phys. 1999. PMID: 10587228
We have demonstrated that the device detects beam misalignments with an accuracy (1 s.d.) of 0.05 mm, which is in agreement with the expected performance. This accuracy is more than sufficient to detect the maximum allowed misalignment of +/-0.5 mm....
We have demonstrated that the device detects beam misalignments with an accuracy (1 s.d.) of 0.05 mm, which is in agreement wi …
Reproductive biology of the smooth butterfly ray Gymnura micrura.
Yokota L, Goitein R, Gianeti MD, Lessa RT. Yokota L, et al. Among authors: goitein r. J Fish Biol. 2012 Sep;81(4):1315-26. doi: 10.1111/j.1095-8649.2012.03413.x. Epub 2012 Aug 15. J Fish Biol. 2012. PMID: 22957872
The W(D50V) (based on the onset of vitellogenesis) was estimated at 359 mm. Uterine fecundity (mean s.d. = 3.8 1.3; range: 1-6) was positively correlated with female size. A 3564% gain in mean wet mass was observed from egg to full-term embryo in utero. ...
The W(D50V) (based on the onset of vitellogenesis) was estimated at 359 mm. Uterine fecundity (mean s.d. = 3.8 1.3; range: 1-6 …