Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1977 1
1982 1
1985 1
1986 1
1988 2
1991 1
1993 6
1994 2
1995 2
1996 7
1997 8
1998 10
1999 12
2000 19
2001 25
2002 41
2003 30
2004 39
2005 72
2006 85
2007 86
2008 94
2009 100
2010 115
2011 138
2012 158
2013 208
2014 181
2015 224
2016 263
2017 265
2018 326
2019 358
2020 403
2021 93
Text availability
Article attribute
Article type
Publication date

Search Results

2,846 results
Results by year
Filters applied: . Clear all
Page 1
Screen-Printed Electrodes Modified with Metal Nanoparticles for Small Molecule Sensing.
Antuña-Jiménez D, González-García MB, Hernández-Santos D, Fanjul-Bolado P. Antuña-Jiménez D, et al. Biosensors (Basel). 2020 Feb 1;10(2):9. doi: 10.3390/bios10020009. Biosensors (Basel). 2020. PMID: 32024126 Free PMC article. Review.
Recent progress in the field of electroanalysis with metal nanoparticle (NP)-based screen-printed electrodes (SPEs) is discussed, focusing on the methods employed to perform the electrode surface functionalization, and the final application achieved wi …
Recent progress in the field of electroanalysis with metal nanoparticle (NP)-based screen-printed electrodes (SPEs) is …
Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.
Economou A. Economou A. Sensors (Basel). 2018 Mar 29;18(4):1032. doi: 10.3390/s18041032. Sensors (Basel). 2018. PMID: 29596391 Free PMC article. Review.
This work reviews the field of screen-printed electrodes (SPEs) modified with "green" metals for electrochemical stripping analysis of toxic elements. ...When combined with the screen-printing technology, such environment-friendly metals can lea …
This work reviews the field of screen-printed electrodes (SPEs) modified with "green" metals for electrochemical stripp …
Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes.
Munteanu FD, Titoiu AM, Marty JL, Vasilescu A. Munteanu FD, et al. Sensors (Basel). 2018 Mar 18;18(3):901. doi: 10.3390/s18030901. Sensors (Basel). 2018. PMID: 29562637 Free PMC article. Review.
This review provides a brief overview of the fabrication and properties of screen-printed electrodes and details the different opportunities to apply them for the detection of antibiotics, detection of bacteria and antibiotic susceptibility. ... …
This review provides a brief overview of the fabrication and properties of screen-printed electrodes and details the di …
Validation of Polymer-Based Screen-Printed Textile Electrodes for Surface EMG Detection.
Pani D, Achilli A, Spanu A, Bonfiglio A, Gazzoni M, Botter A. Pani D, et al. IEEE Trans Neural Syst Rehabil Eng. 2019 Jul;27(7):1370-1377. doi: 10.1109/TNSRE.2019.2916397. Epub 2019 May 23. IEEE Trans Neural Syst Rehabil Eng. 2019. PMID: 31144638
In recent years, the variety of textile electrodes developed for electrophysiological signal detection has increased rapidly. ...These results suggest that the proposed screen-printed textile electrodes may be an effective alternative to the con …
In recent years, the variety of textile electrodes developed for electrophysiological signal detection has increased rapidly. …
Screen-Printed PEDOT:PSS Electrodes on Commercial Finished Textiles for Electrocardiography.
Sinha SK, Noh Y, Reljin N, Treich GM, Hajeb-Mohammadalipour S, Guo Y, Chon KH, Sotzing GA. Sinha SK, et al. ACS Appl Mater Interfaces. 2017 Nov 1;9(43):37524-37528. doi: 10.1021/acsami.7b09954. Epub 2017 Oct 23. ACS Appl Mater Interfaces. 2017. PMID: 29020777
Electrocardiography (ECG) is an essential technique for analyzing and monitoring cardiovascular physiological conditions such as arrhythmia. This article demonstrates the integration of screen-printed ECG circuitry from a commercially available conducting polymer, P …
Electrocardiography (ECG) is an essential technique for analyzing and monitoring cardiovascular physiological conditions such as arrhythmia. …
Screen-printed interdigitated electrodes modified with nanostructured carbon nano-onion films for detecting the cancer biomarker CA19-9.
Ibáñez-Redín G, Furuta RHM, Wilson D, Shimizu FM, Materon EM, Arantes LMRB, Melendez ME, Carvalho AL, Reis RM, Chaur MN, Gonçalves D, Oliveira ON Jr. Ibáñez-Redín G, et al. Mater Sci Eng C Mater Biol Appl. 2019 Jun;99:1502-1508. doi: 10.1016/j.msec.2019.02.065. Epub 2019 Feb 19. Mater Sci Eng C Mater Biol Appl. 2019. PMID: 30889686
Nanostructured capacitive biosensors, combined with inexpensive fabrication technologies, may provide simple, sensitive devices for detecting clinically relevant cancer biomarkers. Herein, we report a novel platform for detecting the pancreatic cancer biomarker CA19 …
Nanostructured capacitive biosensors, combined with inexpensive fabrication technologies, may provide simple, sensitive devices for detectin …
Commercial Screen-Printed Electrodes Based on Carbon Nanomaterials for a Fast and Cost-Effective Voltammetric Determination of Paracetamol, Ibuprofen and Caffeine in Water Samples.
Serrano N, Castilla Ò, Ariño C, Diaz-Cruz MS, Díaz-Cruz JM. Serrano N, et al. Sensors (Basel). 2019 Sep 19;19(18):4039. doi: 10.3390/s19184039. Sensors (Basel). 2019. PMID: 31546788 Free PMC article.
Carbon screen-printed electrode (SPCE), multi-walled carbon nanotubes modified screen-printed electrode (SPCNTE), carbon nanofibers modified screen-printed electrode (SPCNFE), and graphene modified screen-pr
Carbon screen-printed electrode (SPCE), multi-walled carbon nanotubes modified screen-printed electrod
Screen-printed electrodes-based technology: Environmental application to real time monitoring of phenolic degradation by phytoremediation with horseradish roots.
González-Costas JM, Gómez-Fernández S, García J, González-Romero E. González-Costas JM, et al. Sci Total Environ. 2020 Nov 20;744:140782. doi: 10.1016/j.scitotenv.2020.140782. Epub 2020 Jul 11. Sci Total Environ. 2020. PMID: 32693277
The tool used to follow up the evolution of the process is based on screen-printed carbon electrodes (SPCEs) as electrochemical sensor for simultaneous detection of hydroquinone (Epa at 0.047 V), m-cresol (Epa at 0.506 V) and 4-nitrophenol (Epa at 0.69 …
The tool used to follow up the evolution of the process is based on screen-printed carbon electrodes (SPCEs) as electro …
Stretchable screen-printed PEDOT:PSS electrodes for upper-arm surface electromyography.
Spanu A, Bonfiglio A, Pani D. Spanu A, et al. Annu Int Conf IEEE Eng Med Biol Soc. 2020 Jul;2020:4143-4146. doi: 10.1109/EMBC44109.2020.9175701. Annu Int Conf IEEE Eng Med Biol Soc. 2020. PMID: 33018910
However, the available solutions exhibit fragility in relation with the stretchability of the fabric, causing significant performance degradation.In this work, this problem is tackled by a novel deposition approach based on screen-printing technology. The electro
However, the available solutions exhibit fragility in relation with the stretchability of the fabric, causing significant performance degrad …
Graphene Oxide Bulk-Modified Screen-Printed Electrodes Provide Beneficial Electroanalytical Sensing Capabilities.
Rowley-Neale SJ, Brownson DAC, Smith G, Banks CE. Rowley-Neale SJ, et al. Biosensors (Basel). 2020 Mar 19;10(3):27. doi: 10.3390/bios10030027. Biosensors (Basel). 2020. PMID: 32204548 Free PMC article.
We demonstrate a facile methodology for the mass production of graphene oxide (GO) bulk-modified screen-printed electrodes (GO-SPEs) that are economical, highly reproducible and provide analytically useful outputs. ...Furthermore, 10% GO-SPEs exhibit a …
We demonstrate a facile methodology for the mass production of graphene oxide (GO) bulk-modified screen-printed elec
2,846 results
You have reached the last page of results. A maximum of 10,000 results are available.
Jump to page