Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

125 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
Ventilation and cardiac related impedance changes in children undergoing corrective open heart surgery.
Schibler A, Pham TM, Moray AA, Stocker C. Schibler A, et al. Physiol Meas. 2013 Oct;34(10):1319-27. doi: 10.1088/0967-3334/34/10/1319. Epub 2013 Sep 11. Physiol Meas. 2013. PMID: 24021191
In a 19 bed intensive care unit in a tertiary children's hospital ventilation and cardiac related impedance changes were measured using EIT before and after surgery in 18 spontaneously breathing patients. ...We observed a trend towards increased normΔZV in al …
In a 19 bed intensive care unit in a tertiary children's hospital ventilation and cardiac related impedance changes were measu …
Cardiopulmonary exercise parameters in children with atrial septal defect and increased pulmonary blood flow: short-term effects of defect closure.
Pfammatter JP, Zanolari M, Schibler A. Pfammatter JP, et al. Acta Paediatr. 2002;91(1):65-70. doi: 10.1080/080352502753457987. Acta Paediatr. 2002. PMID: 11883822
Sixteen children, aged 6.8-16.1 y, with a defect of 8-23 mm (median 15 mm) and a pulmonary/systemic flow ratio of 1.5-3.5 (median 2.2) were tested and compared with 15 healthy children. ...At peak exercise, patients with a shunt had increased pulmonary resist …
Sixteen children, aged 6.8-16.1 y, with a defect of 8-23 mm (median 15 mm) and a pulmonary/systemic flow ratio of 1.5-3.5 (med …
The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects.
Riedel T, Richards T, Schibler A. Riedel T, et al. Intensive Care Med. 2005 Nov;31(11):1522-8. doi: 10.1007/s00134-005-2734-x. Epub 2005 Sep 30. Intensive Care Med. 2005. PMID: 16195908 Clinical Trial.
A novel approach to analyse the effect of body position and positive pressure ventilation on intrapulmonary tidal volume distribution was evaluated in healthy adult subjects. ...
A novel approach to analyse the effect of body position and positive pressure ventilation on intrapulmonary tidal volume distribution
Effect of smoke inhalation on viscoelastic properties and ventilation distribution in sheep.
Riedel T, Fraser JF, Dunster K, Fitzgibbon J, Schibler A. Riedel T, et al. J Appl Physiol (1985). 2006 Sep;101(3):763-70. doi: 10.1152/japplphysiol.01635.2005. Epub 2006 Apr 20. J Appl Physiol (1985). 2006. PMID: 16627672
We present results of a new smoke inhalation device in sheep and describe pathophysiological changes after smoke exposure. Fifteen female Merino ewes were anesthetized and intubated. ...Electrical impedance tomography showed a shift of ventilation from the dependent …
We present results of a new smoke inhalation device in sheep and describe pathophysiological changes after smoke exposure. Fifteen fe …
Electrical impedance tomography in extremely prematurely born infants and during high frequency oscillatory ventilation analyzed in the frequency domain.
Dunlop S, Hough J, Riedel T, Fraser JF, Dunster K, Schibler A. Dunlop S, et al. Physiol Meas. 2006 Nov;27(11):1151-65. doi: 10.1088/0967-3334/27/11/008. Epub 2006 Sep 20. Physiol Meas. 2006. PMID: 17028408
Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observation period and an EIT image describing regional relative impedance change is generated. ...Most of the change in relative impedance in the …
Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observ …
The assessment of regional lung mechanics with electrical impedance tomography: a pilot study during recruitment manoeuvres.
Grant CA, Fraser JF, Dunster KR, Schibler A. Grant CA, et al. Intensive Care Med. 2009 Jan;35(1):166-70. doi: 10.1007/s00134-008-1324-0. Epub 2008 Oct 11. Intensive Care Med. 2009. PMID: 18850085
DESIGN, SUBJECTS, INTERVENTIONS: A ventilated ovine smoke inhalation lung injury model was used. Respiratory mechanics and regional filling capacity of the lung were measured using EIT pre- and post- recruitment and compared to a control group. ...MAIN RESULTS: Afte …
DESIGN, SUBJECTS, INTERVENTIONS: A ventilated ovine smoke inhalation lung injury model was used. Respiratory mechanics and regional f …
Regional ventilation distribution in non-sedated spontaneously breathing newborns and adults is not different.
Schibler A, Yuill M, Parsley C, Pham T, Gilshenan K, Dakin C. Schibler A, et al. Pediatr Pulmonol. 2009 Sep;44(9):851-8. doi: 10.1002/ppul.21000. Pediatr Pulmonol. 2009. PMID: 19672959
A reversal of the adult pattern has been observed in infants using radionuclide ventilation scanning. But these results have been obtained in infants and children with lung disease. In this study we investigate whether healthy infants have a similar reverse pattern
A reversal of the adult pattern has been observed in infants using radionuclide ventilation scanning. But these results have been obt
Gravity-dependent ventilation distribution in rats measured with electrical impedance tomography.
Rooney D, Friese M, Fraser JF, R Dunster K, Schibler A. Rooney D, et al. Physiol Meas. 2009 Oct;30(10):1075-85. doi: 10.1088/0967-3334/30/10/008. Epub 2009 Sep 9. Physiol Meas. 2009. PMID: 19738318
Regional filling was measured by calculating the slope of the plot of regional versus global relative impedance change on a breath-by-breath basis. ...
Regional filling was measured by calculating the slope of the plot of regional versus global relative impedance change on a breath-by …
Regional ventilation distribution in the first 6 months of life.
Pham TM, Yuill M, Dakin C, Schibler A. Pham TM, et al. Eur Respir J. 2011 Apr;37(4):919-24. doi: 10.1183/09031936.00034310. Epub 2010 Jul 22. Eur Respir J. 2011. PMID: 20650987
Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography.
Grant CA, Pham T, Hough J, Riedel T, Stocker C, Schibler A. Grant CA, et al. Crit Care. 2011;15(1):R37. doi: 10.1186/cc9985. Epub 2011 Jan 25. Crit Care. 2011. PMID: 21266025 Free PMC article.
Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation a …
Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previou …
125 results
Jump to page
Feedback