Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Text availability
Article attribute
Article type
Publication date

Search Results

784 results
Filters applied: . Clear all Results are displayed in a computed author sort order. Results by year timeline is unavailable
Page 1
On-chip microfluidic sorting with fluorescence spectrum detection and multiway separation.
Sugino H, Ozaki K, Shirasaki Y, Arakawa T, Shoji S, Funatsu T. Sugino H, et al. Among authors: shoji s. Lab Chip. 2009 May 7;9(9):1254-60. doi: 10.1039/b815765k. Epub 2009 Feb 13. Lab Chip. 2009. PMID: 19370245
Tashiro, S. Shoji, S. Tsukita and T. Funatsu, Anal. Chem., 2006, 78, 695-701). Four kinds of fluorescence microspheres and three kinds of Escherichia coli cells, expressing different fluorescent proteins, were successfully separated with accuracy and purity b …
Tashiro, S. Shoji, S. Tsukita and T. Funatsu, Anal. Chem., 2006, 78, 695-701). Four kinds of fluorescence microspheres …
Integration in a multilayer microfluidic chip of 8 parallel cell sorters with flow control by sol-gel transition of thermoreversible gelation polymer.
Sugino H, Arakawa T, Nara Y, Shirasaki Y, Ozaki K, Shoji S, Funatsu T. Sugino H, et al. Among authors: shoji s. Lab Chip. 2010 Oct 7;10(19):2559-65. doi: 10.1039/c004192k. Epub 2010 Aug 5. Lab Chip. 2010. PMID: 20689871
Microfluidics assisted synthesis of well-defined spherical polymeric microcapsules and their utilization as potential encapsulants.
Abraham S, Jeong EH, Arakawa T, Shoji S, Kim KC, Kim I, Go JS. Abraham S, et al. Among authors: shoji s. Lab Chip. 2006 Jun;6(6):752-6. doi: 10.1039/b518006f. Epub 2006 Apr 10. Lab Chip. 2006. PMID: 16738726
Integration of pillar array columns into a gradient elution system for pressure-driven liquid chromatography.
Song Y, Noguchi M, Takatsuki K, Sekiguchi T, Mizuno J, Funatsu T, Shoji S, Tsunoda M. Song Y, et al. Among authors: shoji s. Anal Chem. 2012 Jun 5;84(11):4739-45. doi: 10.1021/ac3001836. Epub 2012 May 18. Anal Chem. 2012. PMID: 22540342
A mixed solution of water and fluorescein in methanol was delivered to the separation channel 7 s after the gradient program had been started. ...When the gradient time was 30 s, the analysis could be completed in 30 s, which was only half the time required c …
A mixed solution of water and fluorescein in methanol was delivered to the separation channel 7 s after the gradient program had been …
Use of folded micromachined pillar array column with low-dispersion turns for pressure-driven liquid chromatography.
Aoyama C, Saeki A, Noguchi M, Shirasaki Y, Shoji S, Funatsu T, Mizuno J, Tsunoda M. Aoyama C, et al. Among authors: shoji s. Anal Chem. 2010 Feb 15;82(4):1420-6. doi: 10.1021/ac902491x. Anal Chem. 2010. PMID: 20092311
Successful separation of the fluorescent derivatives of six amino acids was achieved in 140 s. These results indicated that the separation efficiency of microchip chromatography could be significantly improved using a long separation channel with low-dispersion turns....
Successful separation of the fluorescent derivatives of six amino acids was achieved in 140 s. These results indicated that the separ …
Culture-independent method for identification of microbial enzyme-encoding genes by activity-based single-cell sequencing using a water-in-oil microdroplet platform.
Nakamura K, Iizuka R, Nishi S, Yoshida T, Hatada Y, Takaki Y, Iguchi A, Yoon DH, Sekiguchi T, Shoji S, Funatsu T. Nakamura K, et al. Among authors: shoji s. Sci Rep. 2016 Feb 26;6:22259. doi: 10.1038/srep22259. Sci Rep. 2016. PMID: 26915788 Free PMC article.
Fast and quantitative analysis of branched-chain amino acids in biological samples using a pillar array column.
Song Y, Takatsuki K, Isokawa M, Sekiguchi T, Mizuno J, Funatsu T, Shoji S, Tsunoda M. Song Y, et al. Among authors: shoji s. Anal Bioanal Chem. 2013 Oct;405(25):7993-9. doi: 10.1007/s00216-013-7034-7. Epub 2013 May 25. Anal Bioanal Chem. 2013. PMID: 23708693
The NBD derivatives of the three BCAAs and an internal standard (6-aminocaproic acid) were separated in 100 s. The calibration curves for the NBD-BCAAs had good linearity in the range of 0.4-20 μM, using an internal standard. ...
The NBD derivatives of the three BCAAs and an internal standard (6-aminocaproic acid) were separated in 100 s. The calibration curves …
784 results
Jump to page
Feedback