Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1822 1
1832 1
1858 3
1859 1
1860 3
1863 1
1865 1
1866 1
1867 1
1869 1
1877 1
1878 1
1880 1
1882 1
1884 2
1885 2
1888 1
1890 1
1895 1
1896 1
1897 1
1898 2
1899 1
1900 1
1901 1
1902 1
1906 1
1908 1
1910 2
1912 1
1913 2
1917 1
1918 3
1920 2
1921 2
1923 3
1924 2
1928 2
1929 1
1930 2
1933 1
1937 1
1938 1
1939 1
1940 2
1944 3
1945 32
1946 59
1947 72
1948 70
1949 56
1950 98
1951 96
1952 141
1953 112
1954 108
1955 127
1956 105
1957 115
1958 108
1959 119
1960 104
1961 130
1962 147
1963 167
1964 167
1965 137
1966 115
1967 184
1968 193
1969 217
1970 228
1971 248
1972 298
1973 341
1974 292
1975 401
1976 314
1977 320
1978 274
1979 329
1980 333
1981 344
1982 387
1983 383
1984 414
1985 411
1986 416
1987 423
1988 448
1989 561
1990 512
1991 548
1992 490
1993 491
1994 578
1995 558
1996 615
1997 639
1998 623
1999 600
2000 661
2001 701
2002 728
2003 741
2004 812
2005 884
2006 1016
2007 1044
2008 1141
2009 1217
2010 1318
2011 1408
2012 1434
2013 1439
2014 1502
2015 1633
2016 1532
2017 1587
2018 1750
2019 1771
2020 1938
2021 2171
2022 2002
2023 1998
2024 1930
2025 831

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

46,530 results

Results by year

Filters applied: . Clear all
Page 1
Biodegradable Surgical Staple Composed of Magnesium Alloy.
Amano H, Hanada K, Hinoki A, Tainaka T, Shirota C, Sumida W, Yokota K, Murase N, Oshima K, Chiba K, Tanaka Y, Uchida H. Amano H, et al. Sci Rep. 2019 Oct 11;9(1):14671. doi: 10.1038/s41598-019-51123-x. Sci Rep. 2019. PMID: 31604974 Free PMC article.
Currently, surgical staples are composed of non-biodegradable titanium (Ti) that can cause allergic reactions and interfere with imaging. This paper proposes a novel biodegradable magnesium (Mg) alloy staple and discusses analyses conducted to evaluate its safety an …
Currently, surgical staples are composed of non-biodegradable titanium (Ti) that can cause allergic reactions and interfere with imag …
Efficacy of surgical staple line reinforcement in Glissonean stapling: A single-center pilot study.
Toriguchi K, Kaihara S, Kitamura K, Ishikawa T, Oshima N, Kondo M, Kobayashi H, Hashida H, Uryuhara K. Toriguchi K, et al. Asian J Endosc Surg. 2024 Apr;17(2):e13293. doi: 10.1111/ases.13293. Asian J Endosc Surg. 2024. PMID: 38452773
This study investigated surgical SLR as a tool to enhance staple line strength and improve perioperative hemostasis. Here, 10 patients who underwent laparoscopic liver resection using the Tri-StapleTM2.0 Reinforced Reload were included. Patient characteristics, s
This study investigated surgical SLR as a tool to enhance staple line strength and improve perioperative hemostasis. Here, 10 …
Surgical Outcomes, Health Care Utilization, and Costs Associated with Staple Line Buttressing Among Primary Sleeve Gastrectomy Patients.
Roy S, Wang Y, Mallampati R, Johnston S. Roy S, et al. Obes Surg. 2020 Dec;30(12):4935-4944. doi: 10.1007/s11695-020-04917-2. Epub 2020 Sep 10. Obes Surg. 2020. PMID: 32910406 Free PMC article.
PURPOSE: Staple line buttressing is a method of reinforcing surgical staple lines using buttress materials. This study evaluated surgical outcomes, hospital utilization, and hospital costs associated with staple line buttressing among patients w …
PURPOSE: Staple line buttressing is a method of reinforcing surgical staple lines using buttress materials. This study …
A guide to removing surgical staples.
Ford C, Hill B. Ford C, et al. Br J Nurs. 2024 Apr 18;33(8):372-380. doi: 10.12968/bjon.2024.33.8.372. Br J Nurs. 2024. PMID: 38639750 Review.
This article provides a comprehensive overview of the wound healing process, emphasising the critical role of surgical staples in primary intention healing. It outlines the four distinct phases of wound healing including haemostasis, inflammation, proliferation, and matura …
This article provides a comprehensive overview of the wound healing process, emphasising the critical role of surgical staples in pri …
The Science of Stapling: Staple Form.
Rojatkar P, Nalagatla AK, Ricketts CD, Clymer JW, Yosh E. Rojatkar P, et al. Surg Technol Int. 2024 Jul 15;44:115-121. doi: 10.52198/24.STI.44.GS1773. Epub 2024 Mar 19. Surg Technol Int. 2024. PMID: 38547410
This study describes the technological advancements in surgical stapling from the perspective of staple and cartridge design, assessing the impact of staple design when it changes from the traditional B form (also known as 2D staple form) to a three-di …
This study describes the technological advancements in surgical stapling from the perspective of staple and cartridge design, …
Endocutter Staple Height Auto-Adjusts to Tissue Thickness.
Salyer C, Spuzzillo A, Wakefield D, Gomaa D, Thompson J, Goodman M. Salyer C, et al. J Surg Res. 2021 Nov;267:705-711. doi: 10.1016/j.jss.2021.06.024. Epub 2021 Aug 4. J Surg Res. 2021. PMID: 34364256
BACKGROUND: Surgeon choice of the appropriate staple height has been cited as a factor in the mechanical integrity of a staple line. ...RESULTS: Staple heights fired in gastric tissue were significantly different than industry labelled and control staple
BACKGROUND: Surgeon choice of the appropriate staple height has been cited as a factor in the mechanical integrity of a staple
Is staple line reinforcement still needed on contemporary staplers? A benchtop analysis.
Chand B, Meyers C. Chand B, et al. Surg Endosc. 2023 Feb;37(2):1274-1281. doi: 10.1007/s00464-022-09644-6. Epub 2022 Sep 29. Surg Endosc. 2023. PMID: 36175699
A benchtop test on synthetic tissue evaluated the pressure required for staple line leak across surgical staplers with and without G-SLR. METHODS: Staple lines on a consistent thickness synthetic bowel were pressurized to the point of failure (burst pressure) …
A benchtop test on synthetic tissue evaluated the pressure required for staple line leak across surgical staplers with and wit …
Surgical staple as a transcutaneous transducer for ECG electrodes in burnt skin: safe surgical monitoring in major burns.
Sofos SS, Tehrani H, Shokrollahi K, James MI. Sofos SS, et al. Burns. 2013 Jun;39(4):818-9. doi: 10.1016/j.burns.2012.07.029. Epub 2012 Sep 23. Burns. 2013. PMID: 23010087
We present an effective solution based on our experience, of using a common staple or "clip" where the ECG electrode is attached. We can see the patient in the prone position with the back having been debrided and grafted. ...
We present an effective solution based on our experience, of using a common staple or "clip" where the ECG electrode is attached. We …
Comparing Steri-Strip and surgical staple wound closures after primary total knee arthroplasties.
Takayama S, Yamamoto T, Tsuchiya C, Noguchi H, Sato J, Ishii Y. Takayama S, et al. Eur J Orthop Surg Traumatol. 2017 Jan;27(1):113-118. doi: 10.1007/s00590-016-1848-x. Epub 2016 Sep 6. Eur J Orthop Surg Traumatol. 2017. PMID: 27600333
The other 38 knees were closed with skin staples (Staple group) and evaluated retrospectively. RESULTS: No deep or superficial infections developed in this series. ...Thirteen knees developed blisters around the surgical incision in the Steri-Strip group compared wi …
The other 38 knees were closed with skin staples (Staple group) and evaluated retrospectively. RESULTS: No deep or superficial infect …
46,530 results
You have reached the last available page of results. Please see the User Guide for more information.