Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2007 1
2008 2
2009 2
2010 3
2011 5
2012 3
2013 3
2014 6
2015 6
2016 4
2017 9
2018 7
2019 10
2020 7
Text availability
Article attribute
Article type
Publication date

Search Results

49 results
Results by year
Filters applied: . Clear all
Page 1
ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.
Uecker M, Lai P, Murphy MJ, Virtue P, Elad M, Pauly JM, Vasanawala SS, Lustig M. Uecker M, et al. Magn Reson Med. 2014 Mar;71(3):990-1001. doi: 10.1002/mrm.24751. Magn Reson Med. 2014. PMID: 23649942 Free PMC article.
PURPOSE: Parallel imaging allows the reconstruction of images from undersampled multicoil data. ...
PURPOSE: Parallel imaging allows the reconstruction of images from undersampled multicoil data. ...
Hiatal hernias in patients with GERD-like symptoms: evaluation of dynamic real-time MRI vs endoscopy.
Seif Amir Hosseini A, Uhlig J, Streit U, Uhlig A, Sprenger T, Wedi E, Ellenrieder V, Ghadimi M, Uecker M, Voit D, Frahm J, Lotz J, Biggemann L. Seif Amir Hosseini A, et al. Among authors: uecker m. Eur Radiol. 2019 Dec;29(12):6653-6661. doi: 10.1007/s00330-019-06284-8. Epub 2019 Jun 11. Eur Radiol. 2019. PMID: 31187219
Although MRI and endoscopy yield comparable diagnostic accuracy, dynamic MRI sequences are able to visualize hiatal hernias that were occult on static MRI sequences or endoscopy in a relevant number of cases. KEY POINTS: Real-time MRI is a safe and fast imaging modality fo …
Although MRI and endoscopy yield comparable diagnostic accuracy, dynamic MRI sequences are able to visualize hiatal hernias that were occult …
ENLIVE: An Efficient Nonlinear Method for Calibrationless and Robust Parallel Imaging.
Holme HCM, Rosenzweig S, Ong F, Wilke RN, Lustig M, Uecker M. Holme HCM, et al. Among authors: uecker m. Sci Rep. 2019 Feb 28;9(1):3034. doi: 10.1038/s41598-019-39888-7. Sci Rep. 2019. PMID: 30816312 Free PMC article.
Robustness against data inconsistencies, imaging artifacts and acquisition speed are crucial factors limiting the possible range of applications for magnetic resonance imaging (MRI). Therefore, we report a novel calibrationless parallel imaging
Robustness against data inconsistencies, imaging artifacts and acquisition speed are crucial factors limiting the possible range of a …
Intra- and interobserver variability in the diagnosis of GERD by real-time MRI.
Seif Amir Hosseini A, Beham A, Uhlig J, Streit U, Uhlig A, Ellenrieder V, Joseph AA, Voit D, Frahm J, Uecker M, Lotz J, Biggemann L. Seif Amir Hosseini A, et al. Among authors: uecker m. Eur J Radiol. 2018 Jul;104:14-19. doi: 10.1016/j.ejrad.2018.04.029. Epub 2018 Apr 27. Eur J Radiol. 2018. PMID: 29857860
Real-time MRI was based on highly undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion (NLINV). ...
Real-time MRI was based on highly undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by …
Real-time MRI for the dynamic assessment of fundoplication failure in patients with gastroesophageal reflux disease.
Seif Amir Hosseini A, Uhlig J, Streit U, Voit D, Uhlig A, Ellenrieder V, Ghadimi M, Sprenger T, Beham A, Uecker M, Frahm J, Lotz J, Biggemann L. Seif Amir Hosseini A, et al. Among authors: uecker m. Eur Radiol. 2019 Sep;29(9):4691-4698. doi: 10.1007/s00330-019-06025-x. Epub 2019 Feb 25. Eur Radiol. 2019. PMID: 30805702
Real-time MRI (3 Tesla) was performed at 40 ms temporal resolution using undersampled radial fast low-angle shot acquisitions with nonlinear inverse image reconstruction. MRI movies dynamically visualized bolus transit of pineapple juice through the gastroesophageal juncti …
Real-time MRI (3 Tesla) was performed at 40 ms temporal resolution using undersampled radial fast low-angle shot acquisitions with nonlinear …
Fast comprehensive single-sequence four-dimensional pediatric knee MRI with T2 shuffling.
Bao S, Tamir JI, Young JL, Tariq U, Uecker M, Lai P, Chen W, Lustig M, Vasanawala SS. Bao S, et al. Among authors: uecker m. J Magn Reson Imaging. 2017 Jun;45(6):1700-1711. doi: 10.1002/jmri.25508. Epub 2016 Oct 11. J Magn Reson Imaging. 2017. PMID: 27726251 Free PMC article.
PURPOSE: To develop and clinically evaluate a pediatric knee magnetic resonance imaging (MRI) technique based on volumetric fast spin-echo (3DFSE) and compare its diagnostic performance, image quality, and imaging time to that of a conventional …
PURPOSE: To develop and clinically evaluate a pediatric knee magnetic resonance imaging (MRI) technique based on volume …
Dynamic water/fat separation and B 0 inhomogeneity mapping-joint estimation using undersampled triple-echo multi-spoke radial FLASH.
Tan Z, Voit D, Kollmeier JM, Uecker M, Frahm J. Tan Z, et al. Among authors: uecker m. Magn Reson Med. 2019 Sep;82(3):1000-1011. doi: 10.1002/mrm.27795. Epub 2019 Apr 29. Magn Reson Med. 2019. PMID: 31033051
Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils.
Uecker M, Lustig M. Uecker M, et al. Magn Reson Med. 2017 Mar;77(3):1201-1207. doi: 10.1002/mrm.26191. Epub 2016 Mar 11. Magn Reson Med. 2017. PMID: 26970093 Free PMC article.
THEORY AND METHODS: ESPIRiT is a new framework for calibration of the coil sensitivities and reconstruction in parallel magnetic resonance imaging. Applying ESPIRiT to a combined set of physical and virtual conjugate coils (VCC-ESPIRiT) implicitly exploits co …
THEORY AND METHODS: ESPIRiT is a new framework for calibration of the coil sensitivities and reconstruction in parallel magnetic r
Real-Time Magnetic Resonance Imaging: Radial Gradient-Echo Sequences With Nonlinear Inverse Reconstruction.
Frahm J, Voit D, Uecker M. Frahm J, et al. Among authors: uecker m. Invest Radiol. 2019 Dec;54(12):757-766. doi: 10.1097/RLI.0000000000000584. Invest Radiol. 2019. PMID: 31261294
OBJECTIVE: The aim of this study is to evaluate a real-time magnetic resonance imaging (MRI) method that not only promises high spatiotemporal resolution but also practical robustness in a wide range of scientific and clinical applications. ...It is "invisibl …
OBJECTIVE: The aim of this study is to evaluate a real-time magnetic resonance imaging (MRI) method that not only promi …
T(2) shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging.
Tamir JI, Uecker M, Chen W, Lai P, Alley MT, Vasanawala SS, Lustig M. Tamir JI, et al. Among authors: uecker m. Magn Reson Med. 2017 Jan;77(1):180-195. doi: 10.1002/mrm.26102. Epub 2016 Jan 20. Magn Reson Med. 2017. PMID: 26786745 Free PMC article.
PURPOSE: A new acquisition and reconstruction method called T(2) Shuffling is presented for volumetric fast spin-echo (three-dimensional [3D] FSE) imaging. T(2) Shuffling reduces blurring and recovers many images at multiple T(2) contrasts from a single acquisition …
PURPOSE: A new acquisition and reconstruction method called T(2) Shuffling is presented for volumetric fast spin-echo (three-dimensional [3D …
49 results
You have reached the last page of results. A maximum of 10,000 results are available.
Jump to page
Feedback