Long-term results after the Ross procedure with the decellularized AutoTissue Matrix P® bioprosthesis used for pulmonary valve replacement

Eur J Cardiothorac Surg. 2019 May 1;55(5):885-892. doi: 10.1093/ejcts/ezy377.

Abstract

Objectives: Since 1967, the Ross procedure has been performed to treat aortic valve disease using homografts for pulmonary valve replacement. The decellularized Matrix P® prosthesis was developed to overcome (some) limitations of homografts. Until now, the long-term outcome data have been unavailable.

Methods: Between 2002 and 2010, the Ross procedures using the Matrix P prosthesis were performed in 492 adult patients (mean age 57.2 ± 10.6 years, range 21-73 years) at our institution. Patient data were prospectively collected and analysed (3617.3 patient-years, mean follow-up 7.7 ± 4.3 years). Completeness of follow-up at 1, 5 and 10 years was 98.4%, 94.5% and 91.0%, respectively.

Results: Hospital mortality was 3.9% (n = 19). During follow-up, 121 patients died resulting in a survival rate at 5, 10 and 12.5 years of 82.8 ± 1.7%, 70.4 ± 2.3% and 62.4 ± 2.9%, respectively. Echocardiography revealed a high incidence of relevant dysfunction of the Matrix P prosthesis and subsequent right ventricular failure. Primary reoperation/reintervention was necessary for 150 Matrix P and 48 autografts. Freedom from pulmonary valve reoperation at 5, 10 and 12.5 years was 76.2 ± 2.1%, 58.6 ± 2.9% and 53.4 ± 3.4%, respectively. The autograft function and the left ventricular function showed similar results as previously reported with a freedom from autograft reoperation at 5, 10 and 12.5 years of 91.8 ± 1.4%, 86.1 ± 2.0% and 86.1 ± 2.0%, respectively.

Conclusions: The Matrix P prosthesis used for the right ventricular outflow tract reconstruction in the Ross procedure showed unfavourable long-term echocardiographic results with a high rate of reoperation/reintervention for structural pulmonary valve failure. As a consequence, long-term survival of this patient cohort was impaired. Based on these findings, the use of the Matrix P prosthesis for pulmonary valve replacement for Ross procedures in adults should not be recommended.

Keywords: Aortic valve replacement; Bioprosthesis; Heart valve prosthesis; Pulmonary valve replacement; Ross procedure.

MeSH terms

  • Adult
  • Aged
  • Aortic Valve / surgery
  • Bioprosthesis*
  • Echocardiography
  • Female
  • Heart Valve Diseases / surgery
  • Heart Valve Prosthesis Implantation* / adverse effects
  • Heart Valve Prosthesis Implantation* / methods
  • Heart Valve Prosthesis Implantation* / mortality
  • Heart Valve Prosthesis Implantation* / statistics & numerical data
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Pulmonary Valve / transplantation*
  • Reoperation / statistics & numerical data
  • Transplantation, Autologous* / adverse effects
  • Transplantation, Autologous* / methods
  • Transplantation, Autologous* / mortality
  • Transplantation, Autologous* / statistics & numerical data
  • Treatment Outcome
  • Young Adult