Applicational possibilities of linear and non-linear (polynomial) regression and analysis of variance. III. Stability determination of pharmaceutical preparations: stability of diclofenac-sodium in Diclofen injections

Boll Chim Farm. 2004 May;143(4):155-62.

Abstract

This paper presents the application of the regression analysis program and the program for comparing linear regressions (modified method for one-way, analysis of variance), writtens in BASIC program language, for instance, determination of content of Diclofenac-Sodium (active ingredient in DIKLOFEN injections, ampules á 75 mg/3 ml). Stability testing of Diclofenac-Sodium was done by isothermic method of accelerated aging at 4 different temperatures (30 degrees, 40 degrees, 50 degrees and 60 degrees C) as a function of time (4 different duration of treatment: (0-155, 0-145, 0-74 and 0-44 days). The decrease in stability (decrease in the mean value of the content of Diclofenac-Sodium (in %), at different temperatures as a function of time, is possible to describe by, linear dependance. According to the value for regression equation values, the times are assessed in which the content of Diclofenac-Sodium (in %) will decrease by 10%, of the initial value. The times are follows at 30 degrees C 761.02 days, at 40 degrees C 397.26 days, at 50 degrees C 201.96 days and at 60 degrees C 58.85 days. The estimated times (in days) in which the mean value for Diclofenac-Sodium content (in %) will by 10% of the initial values, as a junction of time, are most suitably described by 3rd order parabola. Based on the parameter values which describe the 3rd order parabola, the time was estimated in which Diclofenac-Sodium content mean value (in %) will fall by 10% of the initial one at average ambient temperatures of 20 degrees C and 25 degrees C. The times are: 1409.47 days (20 degrees C) and 1042.39 days (25 degrees C). Based on the value for Fischer's coefficien (F), the comparison of trenf of Diclofenac-Sodium content (in %) shows that, under the influence of different temperatures as a function of time, among them, depending on temperature value, there is: statistically very significant difference (P << .05) at 50 degrees C and lower toward 60 degrees C, i.e. statistically probably significant difference (P > 0.01) at 40 degrees C and lower towards 50 degrees C and there is no statistically significance difference (P >> 0.05) at 30 degrees C towards 40 degrees C.

MeSH terms

  • Algorithms
  • Analysis of Variance
  • Anti-Inflammatory Agents, Non-Steroidal / administration & dosage
  • Anti-Inflammatory Agents, Non-Steroidal / analysis*
  • Diclofenac / administration & dosage
  • Diclofenac / analysis*
  • Drug Stability
  • Injections
  • Linear Models
  • Nonlinear Dynamics
  • Pharmaceutical Solutions
  • Regression Analysis
  • Software
  • Spectrophotometry, Ultraviolet
  • Thermodynamics

Substances

  • Anti-Inflammatory Agents, Non-Steroidal
  • Pharmaceutical Solutions
  • Diclofenac