Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1929 1
1950 2
1951 2
1954 1
1956 1
1966 4
1967 2
1968 4
1969 7
1970 3
1971 3
1972 3
1973 9
1974 8
1975 9
1976 8
1977 7
1978 6
1979 7
1980 6
1981 13
1982 38
1983 43
1984 39
1985 21
1986 40
1987 72
1988 53
1989 58
1990 41
1991 55
1992 59
1993 60
1994 59
1995 77
1996 107
1997 122
1998 118
1999 130
2000 172
2001 169
2002 186
2003 192
2004 212
2005 242
2006 263
2007 253
2008 250
2009 240
2010 250
2011 269
2012 249
2013 254
2014 251
2015 199
2016 203
2017 186
2018 210
2019 192
2020 171
2021 190
2022 174
2023 173
2024 54

Text availability

Article attribute

Article type

Publication date

Search Results

6,120 results

Results by year

Filters applied: . Clear all
Page 1
Taylor dispersion analysis in fused silica capillaries: a tutorial review.
Moser MR, Baker CA. Moser MR, et al. Anal Methods. 2021 Jun 7;13(21):2357-2373. doi: 10.1039/d1ay00588j. Epub 2021 May 17. Anal Methods. 2021. PMID: 33999088 Review.
We first provide a tutorial on the fundamental principles that allow TDA to achieve calibration-free sizing of analytes across a wide range of R(H), with an emphasis on the reduced sample consumption and analysis times that result from utilizing fused silica capilla …
We first provide a tutorial on the fundamental principles that allow TDA to achieve calibration-free sizing of analytes across a wide range …
Supercritical water-treated fused silica capillaries in analytical separations: Status review.
Karásek P, Horká M, Šlais K, Planeta J, Roth M. Karásek P, et al. J Chromatogr A. 2018 Mar 2;1539:1-11. doi: 10.1016/j.chroma.2018.01.051. Epub 2018 Jan 31. J Chromatogr A. 2018. PMID: 29397060 Review.
Near- and supercritical water (SCW) has recently been shown to provide an unusual but effective tool to roughen the inner surface or manipulate the internal diameter of fused silica capillaries for analytical separation methods In this review, the to-date existing v …
Near- and supercritical water (SCW) has recently been shown to provide an unusual but effective tool to roughen the inner surface or manipul …
Nano-etched fused-silica capillary used for on-line preconcentration and electrophoretic separation of bacteriophages from large blood sample volumes with off-line MALDI-TOF mass spectrometry identification.
Horká M, Karásek P, Šalplachta J, Růžička F, Štveráková D, Pantůček R, Roth M. Horká M, et al. Mikrochim Acta. 2020 Feb 19;187(3):177. doi: 10.1007/s00604-020-4154-6. Mikrochim Acta. 2020. PMID: 32076849
The properties of staphylococcal phages from the Siphoviridae, Podoviridae, and Myoviridae families were monitored using capillary electrophoretic methods on fused-silica capillaries with different morphology of surface roughness. Isoelectric points of the examined …
The properties of staphylococcal phages from the Siphoviridae, Podoviridae, and Myoviridae families were monitored using capillary electroph …
An improved design of the fused silica capillary flow cell for absorbance detection in microcolumn liquid chromatography.
Gogaľová Z, Kahle V, Šesták J. Gogaľová Z, et al. Anal Chim Acta. 2023 Jan 15;1238:340637. doi: 10.1016/j.aca.2022.340637. Epub 2022 Nov 18. Anal Chim Acta. 2023. PMID: 36464450
Efficient absorbance detection of a low-volume chromatography peak is a difficult task. In this work, an improved design of the fused silica capillary flow cell for absorbance detection in microcolumn liquid chromatography is described. The cell was fabricated from …
Efficient absorbance detection of a low-volume chromatography peak is a difficult task. In this work, an improved design of the fused
Protocol for Etching Bare-Fused Silica Capillaries for Sheathless Capillary Electrophoresis-Mass Spectrometry Coupling.
Gosset-Erard C, Giorgetti J, Biacchi M, Aubriet F, Leize-Wagner E, Chaimbault P, François YN. Gosset-Erard C, et al. Methods Mol Biol. 2022;2531:49-59. doi: 10.1007/978-1-0716-2493-7_3. Methods Mol Biol. 2022. PMID: 35941477
However, the homemade implementation of a suitable capillary for the porous tip sprayer is more challenging. The porous tip is created by etching the bare-fused silica capillary with hydrofluoric acid. Here we describe the complete process of etching bare-fused
However, the homemade implementation of a suitable capillary for the porous tip sprayer is more challenging. The porous tip is created by et …
Solubilization and aggregation control of silica-polymerizing enzyme fused with a removable soluble protein.
Oguri H, Nakashima K, Godigamuwa K, Okamoto J, Takeda Y, Okazaki F, Sakono M, Kawasaki S. Oguri H, et al. J Biosci Bioeng. 2022 Mar;133(3):222-228. doi: 10.1016/j.jbiosc.2021.11.012. Epub 2021 Dec 17. J Biosci Bioeng. 2022. PMID: 34924266
Silicatein, a silica-polymerizing enzyme, is an attractive and promising biocatalyst in many applications such as the synthesis of bio-functionalized inorganic materials under mild conditions. ...ProS2-Sil and mature silicatein showed similar activities in silica po …
Silicatein, a silica-polymerizing enzyme, is an attractive and promising biocatalyst in many applications such as the synthesis of bi …
Fabrication of silica on chitin in ambient conditions using silicatein fused with a chitin-binding domain.
Godigamuwa K, Nakashima K, Tsujitani S, Kawasaki S. Godigamuwa K, et al. Bioprocess Biosyst Eng. 2021 Sep;44(9):1883-1890. doi: 10.1007/s00449-021-02568-w. Epub 2021 May 11. Bioprocess Biosyst Eng. 2021. PMID: 33974134
High temperatures, harsh pH conditions, and toxic chemicals involved in the conventional synthesis and coating of silica limit the fabrication of new-generation hybrid materials immobilizing live cells and biomolecules such as enzymes and drugs. ...Silicatein, an enzyme fo …
High temperatures, harsh pH conditions, and toxic chemicals involved in the conventional synthesis and coating of silica limit the fa …
Fused-core silica column high-performance liquid chromatography/tandem mass spectrometric determination of rimonabant in mouse plasma.
Hsieh Y, Duncan CJ, Brisson JM. Hsieh Y, et al. Anal Chem. 2007 Aug 1;79(15):5668-73. doi: 10.1021/ac070343g. Epub 2007 Jul 3. Anal Chem. 2007. PMID: 17605466
Fused-core particles are produced by "fusing" a porous silica layer onto a solid silica particle. The efficiencies of columns packed with 2.7 microm "fused-core" particles (a 0.5 microm porous shell fused to a solid 1.7 microm silica
Fused-core particles are produced by "fusing" a porous silica layer onto a solid silica particle. The efficienci
Biological Route to Fabricate Silica on Cellulose Using Immobilized Silicatein Fused with a Carbohydrate-Binding Module.
Godigamuwa K, Nakashima K, Okamoto J, Kawasaki S. Godigamuwa K, et al. Biomacromolecules. 2020 Jul 13;21(7):2922-2928. doi: 10.1021/acs.biomac.0c00730. Epub 2020 Jun 26. Biomacromolecules. 2020. PMID: 32543179
Silicatein is an enzyme capable of catalyzing silica formation under mild conditions and is a promising catalyst for the fabrication of biohybrid materials. ...ProS2-Sil-CBM bound on cellulose catalyzed the formation of a silica layer on the cellulose in the presenc …
Silicatein is an enzyme capable of catalyzing silica formation under mild conditions and is a promising catalyst for the fabrication …
Manufacture of Three-Dimensional Optofluidic Spot-Size Converters in Fused Silica Using Hybrid Laser Microfabrication.
Yu J, Xu J, Zhang A, Song Y, Qi J, Dong Q, Chen J, Liu Z, Chen W, Cheng Y. Yu J, et al. Sensors (Basel). 2022 Dec 2;22(23):9449. doi: 10.3390/s22239449. Sensors (Basel). 2022. PMID: 36502151 Free PMC article.
We propose a hybrid laser microfabrication approach for the manufacture of three-dimensional (3D) optofluidic spot-size converters in fused silica glass by a combination of femtosecond (fs) laser microfabrication and carbon dioxide laser irradiation. Spatiall …
We propose a hybrid laser microfabrication approach for the manufacture of three-dimensional (3D) optofluidic spot-size converters in fus
6,120 results