Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1965 1
1972 1
1976 1
1977 1
1978 1
1979 1
1982 1
1984 1
1985 1
1986 1
1987 3
1988 1
1989 2
1990 2
1991 2
1992 2
1995 2
1996 3
1997 1
1998 3
2000 2
2001 5
2002 1
2003 1
2004 4
2005 2
2006 4
2007 5
2008 3
2009 4
2010 5
2011 5
2012 4
2013 4
2014 8
2015 7
2016 7
2017 9
2018 10
2019 6
2020 15
2021 10
2022 9
2023 5
2024 6

Text availability

Article attribute

Article type

Publication date

Search Results

149 results

Results by year

Filters applied: . Clear all
Page 1
Bone cutting efficiency and heat generation using a traditional fluted Burr and a novel fluteless resurfacing tool.
Meldau JE, LeDuc RC, Havey RM, Barnard ER, Muriuki MG, Kaczmarz N, Patwardhan AG, Schiff AP. Meldau JE, et al. Clin Biomech (Bristol, Avon). 2023 Feb;102:105898. doi: 10.1016/j.clinbiomech.2023.105898. Epub 2023 Feb 2. Clin Biomech (Bristol, Avon). 2023. PMID: 36764102
Cutting rate was calculated from displacement transducer data. Heat generation was measured by thermocouples placed in the bone adjacent to the burring site. ...As a result, the fluted burr produced higher temperatures for the same amount of bone remov
Cutting rate was calculated from displacement transducer data. Heat generation was measured by thermocouples placed in the
Heat Generation During Bony Decompression of Lumbar Spinal Stenosis Using a High-Speed Diamond Drill with or without Automated Irrigation and an Ultrasonic Bone-Cutting Knife: A Single-Blinded Prospective Randomized Controlled Study.
Matthes M, Pillich DT, El Refaee E, Schroeder HWS, Müller JU. Matthes M, et al. World Neurosurg. 2018 Mar;111:e72-e81. doi: 10.1016/j.wneu.2017.11.172. Epub 2017 Dec 8. World Neurosurg. 2018. PMID: 29229343 Clinical Trial.
OBJECTIVE: The main objective of the present prospective, randomized, single-blinded controlled study was to measure heat during bony decompression of lumbar spinal stenosis with high-speed drills and an ultrasonic bone-cutting knife. ...CONCLUSIONS: All meth …
OBJECTIVE: The main objective of the present prospective, randomized, single-blinded controlled study was to measure heat during bony …
The effects of cutting parameters on cutting forces and heat generation when drilling animal bone and biomechanical test materials.
Cseke A, Heinemann R. Cseke A, et al. Med Eng Phys. 2018 Jan;51:24-30. doi: 10.1016/j.medengphy.2017.10.009. Epub 2017 Oct 28. Med Eng Phys. 2018. PMID: 29089237
It also investigated cortical bone anisotropy on the cutting forces, when drilling in axial and radial directions. The cutting forces are only affected by the feed rate, whereas the cutting temperature in contrast is affected by both spindle spe …
It also investigated cortical bone anisotropy on the cutting forces, when drilling in axial and radial directions. The cutt
Experimental investigations and finite element simulation of cutting heat in vibrational and conventional drilling of cortical bone.
Wang Y, Cao M, Zhao X, Zhu G, McClean C, Zhao Y, Fan Y. Wang Y, et al. Med Eng Phys. 2014 Nov;36(11):1408-15. doi: 10.1016/j.medengphy.2014.04.007. Epub 2014 Jun 4. Med Eng Phys. 2014. PMID: 24908355
Heat generated during bone drilling could cause irreversible thermal damage, which can lead to bone necrosis or even osteomyelitis. ...The influence of vibrational frequency and amplitude on cutting heat generation and conduction were studied. T
Heat generated during bone drilling could cause irreversible thermal damage, which can lead to bone necrosis or even os
Temperature Distribution Simulation, Prediction and Sensitivity Analysis of Orthogonal Cutting of Cortical Bone.
Wang Q, Tian H, Dang X, Pan J, Gao Y, Xu Q, Lin Z, Yao Y. Wang Q, et al. Proc Inst Mech Eng H. 2022 Jan;236(1):103-120. doi: 10.1177/09544119211049869. Epub 2021 Oct 7. Proc Inst Mech Eng H. 2022. PMID: 34617494
Bone cutting plays an important role in spine surgical operations. The power devices with high speed employing in bone cutting usually leads to high cutting temperature of the bone tissue. ...This study verifies the influence of ke
Bone cutting plays an important role in spine surgical operations. The power devices with high speed employing in bone
Heat-shock-induced cellular responses to temperature elevations occurring during orthopaedic cutting.
Dolan EB, Haugh MG, Tallon D, Casey C, McNamara LM. Dolan EB, et al. J R Soc Interface. 2012 Dec 7;9(77):3503-13. doi: 10.1098/rsif.2012.0520. Epub 2012 Aug 22. J R Soc Interface. 2012. PMID: 22915633 Free PMC article.
Severe heat-shock to bone cells caused during orthopaedic procedures can result in thermal damage, leading to cell death and initiating bone resorption. By contrast, mild heat-shock has been proposed to induce bone regeneration. In this study, …
Severe heat-shock to bone cells caused during orthopaedic procedures can result in thermal damage, leading to cell death and i …
[Heat distribution within the bone tissue by rotary cutting instrument for IMZ implant. Heat analysis by a real-time thermography].
Watanabe F, Tawada Y, Komatsu S, Hata Y. Watanabe F, et al. Nihon Hotetsu Shika Gakkai Zasshi. 1990 Feb;34(1):18-24. doi: 10.2186/jjps.34.18. Nihon Hotetsu Shika Gakkai Zasshi. 1990. PMID: 2134919 Japanese.
A highly skilled surgical technic is an important factor for the success of implant. But the heat generation during bone preparation will greatly affect the healing process of bone and prognosis of implant. In this study, the heat occurrence and distri …
A highly skilled surgical technic is an important factor for the success of implant. But the heat generation during bone prepa …
Effects of rotary ultrasonic bone drilling on cutting force and temperature in the human bones.
Singh RP, Pandey PM, Behera C, Mridha AR. Singh RP, et al. Proc Inst Mech Eng H. 2020 Aug;234(8):829-842. doi: 10.1177/0954411920925254. Epub 2020 Jun 3. Proc Inst Mech Eng H. 2020. PMID: 32490719

The results revealed that there was a significant difference (p < 0.05) in cutting force and temperature rise for rotary ultrasonic bone drilling and conventional surgical bone drilling. The cutting force obtained in rotary ultrasonic bone

The results revealed that there was a significant difference (p < 0.05) in cutting force and temperature rise for rotary ul

Osteotomy speed, heat development, and bone structure influence by various piezoelectric systems-an in vitro study.
Noetzel N, Fienitz T, Kreppel M, Zirk M, Safi AF, Rothamel D. Noetzel N, et al. Clin Oral Investig. 2019 Nov;23(11):4029-4041. doi: 10.1007/s00784-019-02838-8. Epub 2019 Mar 2. Clin Oral Investig. 2019. PMID: 30826919
OBJECTIVES: The aim of this in vitro study was to evaluate osteotomy speed, heat development, and bone structure influence from osteotomies performed by various piezoelectric devices and insert tips. ...In general, temperature rise was less when using angulat …
OBJECTIVES: The aim of this in vitro study was to evaluate osteotomy speed, heat development, and bone structure influence fro …
Heat Sterilization Effects on Polymeric, FDM-Optimized Orthopedic Cutting Guide for Surgical Procedures.
Frizziero L, Santi GM, Leon-Cardenas C, Ferretti P, Sali M, Gianese F, Crescentini N, Donnici G, Liverani A, Trisolino G, Zarantonello P, Stallone S, Di Gennaro GL. Frizziero L, et al. J Funct Biomater. 2021 Nov 19;12(4):63. doi: 10.3390/jfb12040063. J Funct Biomater. 2021. PMID: 34842761 Free PMC article.
Furthermore, using custom tools chosen for each procedure has shown the best results. Bone correction-related surgeries require customized cutting guides for a greater outcome. ...To achieve this, a DICOM and FDM methodology is proposed for fast prototyping of the …
Furthermore, using custom tools chosen for each procedure has shown the best results. Bone correction-related surgeries require custo …