Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1977 1
1978 1
1979 3
1981 3
1982 3
1984 1
1985 2
1986 3
1987 5
1988 7
1989 10
1990 9
1991 11
1992 20
1993 21
1994 34
1995 30
1996 29
1997 52
1998 35
1999 38
2000 61
2001 50
2002 54
2003 69
2004 69
2005 84
2006 94
2007 107
2008 112
2009 140
2010 155
2011 160
2012 197
2013 218
2014 222
2015 219
2016 269
2017 269
2018 284
2019 237
2020 89
Text availability
Article attribute
Article type
Publication date

Search Results

2,993 results
Results by year
Filters applied: . Clear all
Page 1
Interrater Reliability of Osteopathic Sacral Palpatory Diagnostic Tests Among Osteopathy Students.
Consorti G, Basile F, Pugliese L, Petracca M. Consorti G, et al. J Am Osteopath Assoc. 2018 Oct 1;118(10):637-644. doi: 10.7556/jaoa.2018.132. J Am Osteopath Assoc. 2018. PMID: 30128497
Interrater reliability was evaluated using Fleiss κ statistics. RESULTS: Fifty-two subjects (20 women) were enrolled in the study. ...The tenderness parameter was the most reliable. Our findings are consistent with other interrater reliability s
Interrater reliability was evaluated using Fleiss κ statistics. RESULTS: Fifty-two subjects (20 women) were enrolled in the st
The interrater reliability of static palpation of the thoracic spine for eliciting tenderness and stiffness to test for a manipulable lesion.
Beynon AM, Hebert JJ, Walker BF. Beynon AM, et al. Chiropr Man Therap. 2018 Dec 4;26:49. doi: 10.1186/s12998-018-0218-7. eCollection 2018. Chiropr Man Therap. 2018. PMID: 30524705 Free PMC article.
We calculated interrater agreement using percent agreement, Cohen's Kappa coefficients ( κ ) and prevalence-adjusted bias-adjusted Kappa coefficients (PABAK). ...CONCLUSION: Static palpation was overall moderately reliable for the identification …
We calculated interrater agreement using percent agreement, Cohen's Kappa coefficients ( κ ) and prevalence-adjusted bi …
Reliability of Ayurvedic Diagnosis for Knee Osteoarthritis Patients: A Nested Diagnostic Study Within a Randomized Controlled Trial.
Kessler CS, Morandi A, Kumar A, Dhiman KS, Gupta S, Icke K, Bühner C, Stapelfeldt E, Wischnewsky M, Kronpaß L, Murthy V, Michalsen A, Witt CM. Kessler CS, et al. J Altern Complement Med. 2019 Sep;25(9):910-919. doi: 10.1089/acm.2018.0273. Epub 2019 Jan 17. J Altern Complement Med. 2019. PMID: 30653338 Free PMC article. Clinical Trial.
Evaluation of inter-rater reliability (IRR) of Ayurvedic diagnoses has rarely been performed. The aim of this study was to evaluate IRR of Ayurvedic diagnosis for patients with knee osteoarthritis. ...A nominal group technique as consensus procedure was perfo …
Evaluation of inter-rater reliability (IRR) of Ayurvedic diagnoses has rarely been performed. The aim of this study was to eva …
Interrater Reliability of Ultrasound in the Diagnosis of Sialolithiasis.
Goncalves M, Mantsopoulos K, Schapher ML, Zenk J, Bozzato A, Kuenzel J, Zengel P, Iro H, Koch M. Goncalves M, et al. Ultraschall Med. 2019 Aug;40(4):481-487. doi: 10.1055/a-0837-0712. Epub 2019 Feb 7. Ultraschall Med. 2019. PMID: 30731479 English.
PURPOSE:  The aim of this study was to assess the interrater reliability of ultrasound for diagnosing sialolithiasis. MATERIALS AND METHODS:  A total of 100 consecutive patients with signs of obstructive sialadenopathy were evaluated. ...CONCLUSION:  The stud …
PURPOSE:  The aim of this study was to assess the interrater reliability of ultrasound for diagnosing sialolithiasis. M …
Interrater agreement and reliability assessment of proximal caries detection tools in mixed dentition: An in-vivo study.
Bijle MNA, Chunawala YK, Bohari MR. Bijle MNA, et al. Quintessence Int. 2018;49(6):469-477. doi: 10.3290/j.qi.a40114. Quintessence Int. 2018. PMID: 29637200
Interrater agreement was analyzed as proportion of agreement. Interrater reliability assessment was performed using weighted kappa statistics and intraclass correlation coefficient. ...All methods showed substantial interrater reliability
Interrater agreement was analyzed as proportion of agreement. Interrater reliability assessment was performed using wei
Interrater and intrarater reliability of FDI criteria applied to photographs of posterior tooth-colored restorations.
Kim D, Ahn SY, Kim J, Park SH. Kim D, et al. J Prosthet Dent. 2017 Jul;118(1):18-25.e4. doi: 10.1016/j.prosdent.2016.10.004. Epub 2016 Dec 23. J Prosthet Dent. 2017. PMID: 28024817
To estimate the interrater reliability among the 5 raters, the proportion of agreement was calculated, and the Fleiss multirater kappa statistic was used. ...RESULTS: The interrater proportion of agreement was 0.41 to 0.57, and the kappa value w …
To estimate the interrater reliability among the 5 raters, the proportion of agreement was calculated, and the Fleiss multirat …
Interrater reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression - A systematic review and meta-analysis.
Santelmann H, Franklin J, Bußhoff J, Baethge C. Santelmann H, et al. Schizophr Res. 2016 Oct;176(2-3):357-363. doi: 10.1016/j.schres.2016.07.012. Epub 2016 Jul 25. Schizophr Res. 2016. PMID: 27461400 Review.
Although it is key that diagnostic reliability is sufficient, schizoaffective disorder has been reported to have low interrater reliability. ...Out of 4126 records screened we included 25 studies reporting on 7912 patients diagnosed by different raters …
Although it is key that diagnostic reliability is sufficient, schizoaffective disorder has been reported to have low interrater
Interrater reliability of electrodiagnosis in neonatal brachial plexopathy.
Spires MC, Brown SM, Chang KW, Leonard JA, Yang LJ. Spires MC, et al. Muscle Nerve. 2017 Jan;55(1):69-73. doi: 10.1002/mus.25193. Epub 2016 Nov 4. Muscle Nerve. 2017. PMID: 27191660 Free article.
Simple percentage agreement, the Cohen kappa statistic representing interrater reliability for each nerve root (C5-T1), and overall kappa between examiners were evaluated. RESULTS: Interrater reliabilities were substantial to almost perfe …
Simple percentage agreement, the Cohen kappa statistic representing interrater reliability for each nerve root (C5-T1), …
High Interrater Reliability of Overnight Pulse Oximetry Interpretation Among Inexperienced Physicians Using a Structured Template.
Ayache M, Strohl KP. Ayache M, et al. J Clin Sleep Med. 2018 Apr 15;14(4):541-548. doi: 10.5664/jcsm.7040. J Clin Sleep Med. 2018. PMID: 29609721 Free PMC article.
RESULTS: The overall interrater reliability for final recommendations (sleep apnea suspicion, presence of CPD, and oxygen prescription) was high (kappa = .81, 95% confidence interval [CI] .76-.88). ...CONCLUSIONS: A structured template for OPO interpretation …
RESULTS: The overall interrater reliability for final recommendations (sleep apnea suspicion, presence of CPD, and oxygen pres …
Interrater reliability of the modified scapular assistance test with and without handheld weights.
Kopkow C, Lange T, Schmitt J, Kasten P. Kopkow C, et al. Man Ther. 2015 Dec;20(6):868-74. doi: 10.1016/j.math.2015.04.012. Epub 2015 Apr 16. Man Ther. 2015. PMID: 25935796
STUDY DESIGN: Prospective, blinded interrater reliability study. OBJECTIVE: To determine the interrater reliability of the modified Scapular Assistance Test (mSAT) with and without the use of additional handheld weights. ...Percent agreement, Cohen' …
STUDY DESIGN: Prospective, blinded interrater reliability study. OBJECTIVE: To determine the interrater reliability
2,993 results
Jump to page
Feedback