Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Edit custom filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1952 1
1961 1
1964 1
1965 1
1966 1
1967 1
1970 2
1972 1
1973 1
1975 2
1977 1
1978 5
1979 1
1982 1
1983 3
1984 1
1985 2
1986 3
1989 4
1990 3
1991 1
1992 4
1993 7
1994 8
1995 10
1996 11
1997 24
1998 32
1999 42
2000 56
2001 71
2002 91
2003 67
2004 129
2005 188
2006 231
2007 261
2008 259
2009 315
2010 324
2011 388
2012 376
2013 393
2014 410
2015 399
2016 372
2017 368
2018 370
2019 359
2020 399
2021 369
2022 397
2023 342
2024 320
2025 316
2026 150

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

7,077 results

Results by year

Filters applied: . Clear all
Page 1
Quartz crystal microbalance in soft and biological interfaces.
Reviakine I. Reviakine I. Biointerphases. 2024 Jan 1;19(1):010801. doi: 10.1116/6.0003312. Biointerphases. 2024. PMID: 38416603 Review.
Applications of quartz crystal microbalance with dissipation to studying soft and biological interfaces are reviewed. The focus is primarily on data analysis through viscoelastic modeling and a model-free approach focusing on the acoustic ratio. ...
Applications of quartz crystal microbalance with dissipation to studying soft and biological interfaces are reviewed. The focus is pr …
Quartz crystal microbalance-based biosensors as rapid diagnostic devices for infectious diseases.
Lim HJ, Saha T, Tey BT, Tan WS, Ooi CW. Lim HJ, et al. Biosens Bioelectron. 2020 Nov 15;168:112513. doi: 10.1016/j.bios.2020.112513. Epub 2020 Aug 23. Biosens Bioelectron. 2020. PMID: 32889395 Free PMC article. Review.
Developments of sensitive, rapid, and affordable diagnostic methods are necessary to improve the clinical management of infectious diseases. Quartz crystal microbalance (QCM) systems have emerged as a robust biosensing platform due to their label-free mechanism, which allo …
Developments of sensitive, rapid, and affordable diagnostic methods are necessary to improve the clinical management of infectious diseases. …
Quartz crystal microbalance and atomic force microscopy to characterize mimetic systems based on supported lipids bilayer.
Bonet NF, Cava DG, Vélez M. Bonet NF, et al. Front Mol Biosci. 2022 Aug 3;9:935376. doi: 10.3389/fmolb.2022.935376. eCollection 2022. Front Mol Biosci. 2022. PMID: 35992275 Free PMC article. Review.
Quartz Crystal Microbalance (QCM) with dissipation and Atomic Force Microscopy (AFM) are two characterization techniques that allow describing processes taking place at solid-liquid interfaces. ...
Quartz Crystal Microbalance (QCM) with dissipation and Atomic Force Microscopy (AFM) are two characterization techniques that allow d …
Quartz crystal microbalance: Sensing cell-substrate adhesion and beyond.
Chen JY, Penn LS, Xi J. Chen JY, et al. Biosens Bioelectron. 2018 Jan 15;99:593-602. doi: 10.1016/j.bios.2017.08.032. Epub 2017 Aug 15. Biosens Bioelectron. 2018. PMID: 28830033 Review.
Finding innovative methods to probe the adhesion of cells in their native state can greatly advance the understanding of control and regulation of cellular behavior and their impact on human health. The quartz crystal microbalance (QCM) is a label-free, biosensing system t …
Finding innovative methods to probe the adhesion of cells in their native state can greatly advance the understanding of control and regulat …
Quartz Crystal Microbalance Electronic Interfacing Systems: A Review.
Alassi A, Benammar M, Brett D. Alassi A, et al. Sensors (Basel). 2017 Dec 5;17(12):2799. doi: 10.3390/s17122799. Sensors (Basel). 2017. PMID: 29206212 Free PMC article. Review.
Quartz Crystal Microbalance (QCM) sensors are actively being implemented in various fields due to their compatibility with different operating conditions in gaseous/liquid mediums for a wide range of measurements. ...Finally, specific design considerations of high-temperat …
Quartz Crystal Microbalance (QCM) sensors are actively being implemented in various fields due to their compatibility with different …
Molecular Imprinting Technology in Quartz Crystal Microbalance (QCM) Sensors.
Emir Diltemiz S, Keçili R, Ersöz A, Say R. Emir Diltemiz S, et al. Sensors (Basel). 2017 Feb 24;17(3):454. doi: 10.3390/s17030454. Sensors (Basel). 2017. PMID: 28245588 Free PMC article. Review.
On the other hand, the Quartz Crystal Microbalance (QCM) is an analytical tool based on the measurement of small mass changes on the sensor surface. ...
On the other hand, the Quartz Crystal Microbalance (QCM) is an analytical tool based on the measurement of small mass changes on the …
Quartz Crystal Microbalance With Dissipation Monitoring: A Powerful Method to Predict the in vivo Behavior of Bioengineered Surfaces.
Tonda-Turo C, Carmagnola I, Ciardelli G. Tonda-Turo C, et al. Front Bioeng Biotechnol. 2018 Oct 30;6:158. doi: 10.3389/fbioe.2018.00158. eCollection 2018. Front Bioeng Biotechnol. 2018. PMID: 30425985 Free PMC article. Review.
The Quartz Crystal Microbalance with dissipation monitoring (QCM-D) is a tool to measure mass and viscosity in processes occurring at or near surfaces, or within thin films. ...
The Quartz Crystal Microbalance with dissipation monitoring (QCM-D) is a tool to measure mass and viscosity in processes occurring at …
Molecular and cellular level characterization of cytoskeletal mechanics using a quartz crystal microbalance.
Kerivan EM, Tobin L, Basil M, Reinemann DN. Kerivan EM, et al. Cytoskeleton (Hoboken). 2023 May-Jun;80(5-6):100-111. doi: 10.1002/cm.21752. Epub 2023 Mar 24. Cytoskeleton (Hoboken). 2023. PMID: 36891731 Free PMC article. Review.
A quartz crystal microbalance (QCM) is an instrument that has the ability to measure nanogram-level changes in mass on a quartz sensor and is traditionally used to probe surface interactions and assembly kinetics of synthetic systems. ...
A quartz crystal microbalance (QCM) is an instrument that has the ability to measure nanogram-level changes in mass on a quartz senso …
Miau, a microbalance autosampler.
Carvalho MC. Carvalho MC. HardwareX. 2021 Jun 25;10:e00215. doi: 10.1016/j.ohx.2021.e00215. eCollection 2021 Oct. HardwareX. 2021. PMID: 35607678 Free PMC article.
Powder weighing is an essential but tedious activity in many branches of science. Here I describe a MIcrobalance AUtosampler (miau) that transfers solids in the sub-mg range to a microbalance. ...Setup for daily use is simple, and the microbalance can be easi …
Powder weighing is an essential but tedious activity in many branches of science. Here I describe a MIcrobalance AUtosampler (miau) t …
Exploring tear viscosity with quartz crystal microbalance technology.
Muñoz G, Millicovsky M, Cerrudo J, Peñalva A, Machtey M, Reta J, Torres R, Campana D, Zalazar M. Muñoz G, et al. Rev Sci Instrum. 2024 Jul 1;95(7):075107. doi: 10.1063/5.0207182. Rev Sci Instrum. 2024. PMID: 39023347
This research introduces a novel Quartz Crystal Microbalance (QCM)-based method for tear viscosity measurement, offering a viscometer prototype that operates with minimal sample volumes. ...
This research introduces a novel Quartz Crystal Microbalance (QCM)-based method for tear viscosity measurement, offering a viscometer …
7,077 results