Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1978 1
1983 1
1984 1
1987 5
1988 5
1989 6
1990 11
1991 16
1992 8
1993 16
1994 16
1995 13
1996 17
1997 21
1998 17
1999 13
2000 22
2001 24
2002 24
2003 31
2004 21
2005 31
2006 44
2007 41
2008 70
2009 59
2010 70
2011 74
2012 76
2013 96
2014 82
2015 83
2016 99
2017 122
2018 104
2019 86
2020 107
2021 123
2022 123
2023 118
2024 110
2025 127
2026 2

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

1,884 results

Results by year

Filters applied: Abstract. Clear all
Page 1
Effect of screw angulation and multiple insertions on load-to-failure of polyaxial locking system.
Glowacki J, Bartkowiak T, Paczos P, Mietlinski P, Zawadzki P, Lapaj L. Glowacki J, et al. PLoS One. 2023 Dec 11;18(12):e0295526. doi: 10.1371/journal.pone.0295526. eCollection 2023. PLoS One. 2023. PMID: 38079421 Free PMC article.
PURPOSE: Polyaxial locking plates rely on the alignment between the thread-to-thread connections of the screw head and the plate hole. ...METHODS: Polyaxial locking screws were inserted into the plates at various angles (0,10,15, -15 off-axis). …
PURPOSE: Polyaxial locking plates rely on the alignment between the thread-to-thread connections of the screw head and the …
Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study.
de Souza AF, Pereira CAM, Costa C, Fürst A, Kümmerle JM, De Zoppa ALV. de Souza AF, et al. Vet Comp Orthop Traumatol. 2024 Nov;37(6):263-272. doi: 10.1055/s-0044-1787680. Epub 2024 Jun 4. Vet Comp Orthop Traumatol. 2024. PMID: 38834168
OBJECTIVE: The aim of this study was to measure the mechanical properties and failure mode of an ex vivo model of proximal interphalangeal arthrodesis in horses with different methods of proximal screw fixation using a locking compression plate. ...Single-cyc …
OBJECTIVE: The aim of this study was to measure the mechanical properties and failure mode of an ex vivo model of proximal interphala …
Plate and screw fixation of arthroscopically assisted tibial tuberosity osteotomy: technique and results.
Stevens JM, Barton SB, Alexander M, Eldridge JD, Clark D. Stevens JM, et al. Eur J Orthop Surg Traumatol. 2020 Jan;30(1):139-145. doi: 10.1007/s00590-019-02536-x. Epub 2019 Aug 28. Eur J Orthop Surg Traumatol. 2020. PMID: 31456034
INTRODUCTION: We describe a fixation technique for tibial tuberosity osteotomies (TTO) utilising a plate and screw construct which adheres to established principles of bone healing. We record and discuss the complication profile and benefits of this technique …
INTRODUCTION: We describe a fixation technique for tibial tuberosity osteotomies (TTO) utilising a plate and screw construct w …
Inadequate proximal screw fixation increases risk of failure following plate fixation of diaphyseal humerus fractures.
Mistry MR, Tat J, Husain R, Sheth U, Richards RR, Nam D. Mistry MR, et al. J Orthop Surg Res. 2023 Feb 27;18(1):142. doi: 10.1186/s13018-023-03566-2. J Orthop Surg Res. 2023. PMID: 36843092 Free PMC article.
Eleven of eighty-five humeral shaft fractures had aseptic mechanical failure requiring revision (12.9%), following initial plate fixation. Fracture characteristics (AO type, comminution, location) and fracture fixation (plate type, multiplanar, number of s
Eleven of eighty-five humeral shaft fractures had aseptic mechanical failure requiring revision (12.9%), following initial plate
Biomechanical comparisons of hook plate and screw fixations in split-type greater tuberosity fractures of the humerus.
Kuan FC, Hsu KL, Hong CK, Chen Y, Chiang CH, Chang HM, Su WR. Kuan FC, et al. J Shoulder Elbow Surg. 2022 Jun;31(6):1308-1315. doi: 10.1016/j.jse.2021.12.023. Epub 2022 Jan 21. J Shoulder Elbow Surg. 2022. PMID: 35066120
All of the specimens completed the entire cyclic loading test without catastrophic failure, and the fragment displacement after 500 cycles was 0.4 0.2 mm for the hook plate and 2.1 0.3 mm for screw fixation, which was statistically lower in the plate g …
All of the specimens completed the entire cyclic loading test without catastrophic failure, and the fragment displacement after 500 c …
[Polyaxial angle stability].
Lenz M, Rocci M, Altmann M, Gueorguiev B. Lenz M, et al. Unfallchirurgie (Heidelb). 2025 Dec;128(12):900-906. doi: 10.1007/s00113-025-01628-0. Epub 2025 Sep 3. Unfallchirurgie (Heidelb). 2025. PMID: 40900319 Review. German.
Polyaxial screw systems are the state of the art in the field of fracture fixation. In contrast to conventional monoaxial systems, the polyaxial constructs enable variable screw angulation, enhancing the adaptability of plate-screw configurations in di …
Polyaxial screw systems are the state of the art in the field of fracture fixation. In contrast to conventional monoaxial systems, th …
The Impact of Eccentric Diaphyseal Plate and Screw Placement on the Risk of Peri-Implant Fracture.
Namm JD, Morris RP, Speck FL 3rd, Lindsey RW. Namm JD, et al. J Bone Joint Surg Am. 2018 Oct 17;100(20):1765-1770. doi: 10.2106/JBJS.18.00024. J Bone Joint Surg Am. 2018. PMID: 30334887
METHODS: Twenty osteoporotic fourth-generation composite left humeri were divided into 4 groups and plated with stainless-steel 6-hole locking plates and 4.5-mm screws. Group 1 (control group) consisted of a centrally positioned plate with a centrally …
METHODS: Twenty osteoporotic fourth-generation composite left humeri were divided into 4 groups and plated with stainless-steel 6-hol …
Bone plate-screw constructs for osteosynthesis - recommendations for standardized mechanical torsion and bending tests.
Schorler H, Wendlandt R, Jürgens C, Schulz AP, Kaddick C, Capanni F. Schorler H, et al. Biomed Tech (Berl). 2018 Nov 27;63(6):719-727. doi: 10.1515/bmt-2017-0126. Biomed Tech (Berl). 2018. PMID: 29252187
This paper follows up on a recent systematic review of test methods and parameters for biomechanical testing of bone plates and it is the first study that contains recommendations for standardized mechanical testing of bone plate-screw construct …
This paper follows up on a recent systematic review of test methods and parameters for biomechanical testing of bone plates an …
Comparison of Cannulated Screw Combined with Medial Femoral Plate and Simple Cannulated Screw in the Treatment of Pauwels Type III Femoral Neck Fracture: A Meta-analysis with Trial Sequential Analysis.
Li M, Ren C, Ma T, Li Z, Xu Y, Sun L, Lu Y, Wang Q, Xue H, Huang Q, Zhang K. Li M, et al. J Coll Physicians Surg Pak. 2023 Jul;33(7):792-798. doi: 10.29271/jcpsp.2023.07.792. J Coll Physicians Surg Pak. 2023. PMID: 37401223
This study aimed to compare the efficacy of cannulated screw combined with medial femoral plate and simple cannulated screw for Pauwels type III femoral neck fracture. ...This demonstrated that compared to that with the simple cannulated screw, the can …
This study aimed to compare the efficacy of cannulated screw combined with medial femoral plate and simple cannulated screw
Biomechanical comparison of titanium alloy additively manufactured and conventionally manufactured plate-screw constructs.
Polak S, Beever L, Wade A, Fukuoka M, Worth AJ. Polak S, et al. N Z Vet J. 2024 Jan;72(1):17-27. doi: 10.1080/00480169.2023.2264805. Epub 2023 Dec 10. N Z Vet J. 2024. PMID: 37772312 Free article.
AIM: To biomechanically compare the bending stiffness, strength, and cyclic fatigue of titanium additively manufactured (AM) and conventionally manufactured (CM) limited contact plates (LCP) of equivalent dimensions using plate-screw constructs. METHODS: Twen …
AIM: To biomechanically compare the bending stiffness, strength, and cyclic fatigue of titanium additively manufactured (AM) and conventiona …
1,884 results