Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1958 4
1959 2
1961 2
1962 1
1963 2
1964 3
1965 2
1967 3
1968 2
1969 1
1970 3
1971 2
1972 8
1973 4
1974 10
1975 8
1976 3
1977 3
1978 5
1979 5
1980 8
1981 3
1982 4
1983 6
1984 7
1985 5
1986 5
1987 10
1988 4
1989 6
1990 10
1991 9
1992 11
1993 8
1994 7
1995 3
1996 9
1997 5
1998 13
1999 9
2000 15
2001 12
2002 15
2003 13
2004 20
2005 18
2006 16
2007 13
2008 21
2009 29
2010 28
2011 38
2012 49
2013 25
2014 47
2015 44
2016 54
2017 45
2018 46
2019 53
2020 58
2021 43
2022 23
Text availability
Article attribute
Article type
Publication date

Search Results

875 results
Results by year
Filters applied: . Clear all
Page 1
Plastic scintillation dosimeter with a conical mirror for measuring 3D dose distribution.
Tsuneda M, Nishio T, Ezura T, Karasawa K. Tsuneda M, et al. Med Phys. 2021 Oct;48(10):5639-5650. doi: 10.1002/mp.15164. Epub 2021 Aug 20. Med Phys. 2021. PMID: 34389992
PURPOSE: To test the measurement technique of the three-dimensional (3D) dose distribution measured image by capturing the scintillation light generated using a plastic scintillator and a scintillating screen. METHODS: Our imaging system constituted a …
PURPOSE: To test the measurement technique of the three-dimensional (3D) dose distribution measured image by capturing the scintillation
[Characterization of Small Volume Plastic Scintillation Detector].
Fukui Y, Hamada Y, Noma K, Harada N. Fukui Y, et al. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2019;75(7):652-658. doi: 10.6009/jjrt.2019_JSRT_75.7.652. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2019. PMID: 31327776 Free article. Japanese.
Some radiation detectors are used for quality assurance and measured to radiation dose for high precision external beam radiotherapy. Recently, plastic scintillation detectors for MeV X-ray measurement are commercially released. ...The output coefficient of plast
Some radiation detectors are used for quality assurance and measured to radiation dose for high precision external beam radiotherapy. Recent …
The ecological half-life of radiocesium in surficial bottom sediments of five ponds in Fukushima based on in situ measurements with plastic scintillation fibers.
Katengeza EW , Sanada Y , Yoshimura K , Ochi K , Iimoto T . Katengeza EW , et al. Environ Sci Process Impacts. 2020 Jul 1;22(7):1566-1576. doi: 10.1039/d0em00160k. Epub 2020 Jul 6. Environ Sci Process Impacts. 2020. PMID: 32628231 Review.
Plastic scintillation fibers (PSFs) have been instrumental in in situ surface contamination surveys post the Fukushima Daichi Nuclear Power Plant accident. ...
Plastic scintillation fibers (PSFs) have been instrumental in in situ surface contamination surveys post the Fukushima Daichi
Characterization of novel 3D printed plastic scintillation dosimeters.
Lynch N, Monajemi T, Robar JL. Lynch N, et al. Biomed Phys Eng Express. 2020 Sep 8;6(5):055014. doi: 10.1088/2057-1976/aba880. Biomed Phys Eng Express. 2020. PMID: 33444245
We propose a new methodology for the fabrication and evaluation of scintillating detector elements using a consumer grade fusion deposition modeling (FDM) 3D printer. In this study we performed a comprehensive investigation into both the effects of the 3D printing process …
We propose a new methodology for the fabrication and evaluation of scintillating detector elements using a consumer grade fusion depo …
Computational modeling for the evaluation of suppressed scintillation yields in plastic scintillators using Geant4.
Kikuta S, Sakata D, Fukuda S. Kikuta S, et al. Phys Med. 2021 Sep;89:258-264. doi: 10.1016/j.ejmp.2021.08.005. Epub 2021 Aug 28. Phys Med. 2021. PMID: 34464937
In their study, the track structure simulations could reproduce measured yields of scintillation. However, Ogawa et al.'s model was not suitable for estimating the scintillation yields when the particle energy was low when using condensed history simulations. …
In their study, the track structure simulations could reproduce measured yields of scintillation. However, Ogawa et al.'s mode …
Photoluminescence and scintillation characteristics of Bi-loaded PVK-based plastic scintillators for the high counting-rate measurement of high-energy X-rays.
Sato A, Magi A, Koshimizu M, Fujimoto Y, Kishimoto S, Asai K. Sato A, et al. RSC Adv. 2021 Apr 27;11(26):15581-15589. doi: 10.1039/d1ra01878g. eCollection 2021 Apr 26. RSC Adv. 2021. PMID: 35481211 Free PMC article.
The detection efficiency per 1 mm thickness achieved by a PVK-based plastic scintillator loaded with 10 wt% Bi was 2.5-times higher than that achieved by a commercial polyvinyltoluene (PVT)-based plastic scintillator loaded with 5 wt% Pb, EJ-256. The l …
The detection efficiency per 1 mm thickness achieved by a PVK-based plastic scintillator loaded with 10 wt% Bi was 2.5-times h …
Fabrication and characterization of a stemless plastic scintillation detector.
Hupman MA, Monajemi T, Valitova I, Hill IG, Syme A. Hupman MA, et al. Med Phys. 2020 Nov;47(11):5882-5889. doi: 10.1002/mp.14475. Epub 2020 Oct 6. Med Phys. 2020. PMID: 32966652
PURPOSE: To fabricate a stemless plastic scintillation detector (SPSD) and characterize its linearity and reproducibility, and its dependence on energy and dose per pulse; and to apply it to clinical PDD and output factor measurements. ...The impact of Cerenkov emis …
PURPOSE: To fabricate a stemless plastic scintillation detector (SPSD) and characterize its linearity and reproducibility, and …
First measurements with a plastic scintillation dosimeter at the Australian MRI-LINAC.
Madden L, Archer J, Li E, Jelen U, Dong B, Roberts N, Holloway L, Rosenfeld A. Madden L, et al. Phys Med Biol. 2019 Sep 4;64(17):175015. doi: 10.1088/1361-6560/ab324b. Phys Med Biol. 2019. PMID: 31307025
MRI-LINACs combine MRI and LINAC technologies with the potential for image guided radiation therapy with optimal soft-tissue contrast. In this work, we present the advantages and limitations of plastic scintillation dosimeters (PSDs) for relative dosimetry with MRI- …
MRI-LINACs combine MRI and LINAC technologies with the potential for image guided radiation therapy with optimal soft-tissue contrast. In th …
In-line MRI-LINAC depth dose measurements using an in-house plastic scintillation dosimeter.
Madden L, Roberts N, Jelen U, Dong B, Holloway L, Metcalfe P, Rosenfeld A, Li E. Madden L, et al. Biomed Phys Eng Express. 2021 Feb 11;7(2). doi: 10.1088/2057-1976/abe295. Biomed Phys Eng Express. 2021. PMID: 33530066
Plastic scintillation dosimeters (PSDs) have many properties that make them desirable for relative dosimetry with MRI-LINACs. An in-house PSD, Farmer ionisation chamber and Gafchromic EBT3 film were used to measure central axis percentage depth dose distributions (P
Plastic scintillation dosimeters (PSDs) have many properties that make them desirable for relative dosimetry with MRI-LINACs.
MRI-LINAC beam profile measurements using a plastic scintillation dosimeter.
Madden L, Archer J, Li E, Jelen U, Dong B, Holloway L, Rosenfeld A. Madden L, et al. Phys Med. 2020 May;73:111-116. doi: 10.1016/j.ejmp.2020.04.016. Epub 2020 Apr 28. Phys Med. 2020. PMID: 32361155
Plastic scintillation dosimeters (PSDs) possess many desirable qualities for dosimetry with LINACs. ...
Plastic scintillation dosimeters (PSDs) possess many desirable qualities for dosimetry with LINACs. ...
875 results