Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1991 1
1993 1
1994 1
1995 5
1996 3
1997 8
1998 2
1999 6
2000 8
2001 4
2002 9
2003 9
2004 10
2005 10
2006 15
2007 18
2008 10
2009 23
2010 29
2011 30
2012 30
2013 22
2014 39
2015 29
2016 37
2017 52
2018 28
2019 25
2020 35
2021 2
Text availability
Article attribute
Article type
Publication date

Search Results

446 results
Results by year
Filters applied: . Clear all
Page 1
Subaxial Cervical Pedicle Screw in Traumatic Spinal Surgery.
Jung YG, Lee S, Jeong SK, Kim M, Park JH. Jung YG, et al. Korean J Neurotrauma. 2020 Apr 24;16(1):18-27. doi: 10.13004/kjnt.2020.16.e13. eCollection 2020 Apr. Korean J Neurotrauma. 2020. PMID: 32395448 Free PMC article. Review.
In addition, the CPS can penetrate through a linear cervical spinal pedicle fracture gap and could stabilize three-column injury. ...Freehand technique that can be performed quickly without heavy equipment is suitable for emergency situation. Possible complications due to …
In addition, the CPS can penetrate through a linear cervical spinal pedicle fracture gap and could stabilize three-column injury. ... …
The Arrival of Robotics in Spine Surgery: A Review of the Literature.
Ghasem A, Sharma A, Greif DN, Alam M, Maaieh MA. Ghasem A, et al. Spine (Phila Pa 1976). 2018 Dec 1;43(23):1670-1677. doi: 10.1097/BRS.0000000000002695. Spine (Phila Pa 1976). 2018. PMID: 29672420 Review.
SUMMARY OF BACKGROUND DATA: Misplacement of pedicle screws in conventional open as well as minimally invasive surgical procedures has prompted the need for innovation and allowed the emergence of robotics in spine surgery. ...CONCLUSION: The implementation of roboti …
SUMMARY OF BACKGROUND DATA: Misplacement of pedicle screws in conventional open as well as minimally invasive surgical procedu …
Improved Accuracy of Cervical Spinal Surgery With Robot-Assisted Screw Insertion: A Prospective, Randomized, Controlled Study.
Fan M, Liu Y, He D, Han X, Zhao J, Duan F, Liu B, Tian W. Fan M, et al. Spine (Phila Pa 1976). 2020 Mar 1;45(5):285-291. doi: 10.1097/BRS.0000000000003258. Spine (Phila Pa 1976). 2020. PMID: 31568094 Clinical Trial.
OBJECTIVE: To compare robot-assisted and conventional implantation techniques by evaluating the accuracy and safety of implanting screws in cervical vertebrae. SUMMARY OF BACKGROUND DATA: Cervical spinal surgery is difficult and dangerous as screw misplace
OBJECTIVE: To compare robot-assisted and conventional implantation techniques by evaluating the accuracy and safety of implanting screws
Comparison of pedicle screw misplacement following open vs. percutaneous dorsal instrumentation after traumatic spinal fracture.
Kreinest M, Rillig J, Küffer M, Grützner PA, Tinelli M, Matschke S. Kreinest M, et al. Eur J Trauma Emerg Surg. 2019 Oct 17. doi: 10.1007/s00068-019-01245-8. Online ahead of print. Eur J Trauma Emerg Surg. 2019. PMID: 31624857
Besides the traditional open surgical procedure, the percutaneous positioning of pedicle screws is now widely used. The aim of the current study is to compare pedicle screw misplacement following open vs. percutaneous dorsal instrumentation after traumatic …
Besides the traditional open surgical procedure, the percutaneous positioning of pedicle screws is now widely used. The aim of the cu …
Accuracy Analysis of Iliac Screw Using Freehand Technique in Spinal Surgery : Relation between Screw Breach and Revision Surgery.
Lee S, Jung SK, Keshen SG, Lewis SJ, Park JH. Lee S, et al. J Korean Neurosurg Soc. 2020 Mar;63(2):210-217. doi: 10.3340/jkns.2019.0090. Epub 2020 Jan 15. J Korean Neurosurg Soc. 2020. PMID: 31931555 Free PMC article.
The breaches were classified based on the superior, inferior, lateral, and medial iliac wall violation by the screw. According to the length of screw extrusion, the classification grades were as follows : grade 1, screw extrusion <1 cm; grade II, 1 cm s
The breaches were classified based on the superior, inferior, lateral, and medial iliac wall violation by the screw. According to the …
Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial.
Han X, Tian W, Liu Y, Liu B, He D, Sun Y, Han X, Fan M, Zhao J, Xu Y, Zhang Q. Han X, et al. J Neurosurg Spine. 2019 Feb 8:1-8. doi: 10.3171/2018.10.SPINE18487. Online ahead of print. J Neurosurg Spine. 2019. PMID: 30738398
OBJECTIVEThe object of this study was to compare the safety and accuracy of pedicle screw placement using the TiRobot system versus conventional fluoroscopy in thoracolumbar spinal surgery.METHODSPatients with degenerative or traumatic thoracolumbar spinal di …
OBJECTIVEThe object of this study was to compare the safety and accuracy of pedicle screw placement using the TiRobot system versus c …
Emergency Aortic Control for Pedicle Screw Misplacement During Spinal Fixation.
Monzio-Compagnoni N, Aseni P, Romani F. Monzio-Compagnoni N, et al. Ann Vasc Surg. 2020 Jul;66:669.e1-669.e3. doi: 10.1016/j.avsg.2020.01.007. Epub 2020 Jan 8. Ann Vasc Surg. 2020. PMID: 31923600
Aortic iatrogenic injuries during spinal instrumentation are rare but carry a high risk of mortality. ...The neurosurgical procedure was complicated by the misplacement of a spinal pedicle screw, which almost penetrated the descending thoracic aorta. . …
Aortic iatrogenic injuries during spinal instrumentation are rare but carry a high risk of mortality. ...The neurosurgical procedure …
Transabdominal Motor Action Potential Monitoring of Pedicle Screw Placement During Minimally Invasive Spinal Procedures: A Case Study.
Narayan A, Taylor S, Taylor W. Narayan A, et al. Cureus. 2020 Jul 31;12(7):e9497. doi: 10.7759/cureus.9497. Cureus. 2020. PMID: 32879821 Free PMC article.
Precise pedicle screw placement is a critical skill during minimally invasive spinal surgeries but can pose various challenges. ...Transabdominal motor action potential (TaMAP) has been examined as a possible effective neuromonitoring alternative and is hypothesized …
Precise pedicle screw placement is a critical skill during minimally invasive spinal surgeries but can pose various challenges …
Pedicle screw instrumentation and spinal deformities: have we gone too far?
McCormick J, Aebi M, Toby D, Arlet V. McCormick J, et al. Eur Spine J. 2013 Mar;22 Suppl 2(Suppl 2):S216-24. doi: 10.1007/s00586-012-2300-5. Epub 2012 Apr 25. Eur Spine J. 2013. PMID: 22531899 Free PMC article.
INTRODUCTION: Placement of pedicle screws within the thoracic and lumbar spine has become the "state of the art" for the treatment of spinal deformities. ...RESULTS: Pedicle screw instrumentation in the treatment of spinal deformity is here to stay, ho …
INTRODUCTION: Placement of pedicle screws within the thoracic and lumbar spine has become the "state of the art" for the treatment of …
Comparative Outcomes of Cortical Screw Trajectory Fixation and Pedicle Screw Fixation in Lumbar Spinal Fusion: Systematic Review and Meta-analysis.
Keorochana G, Pairuchvej S, Trathitephun W, Arirachakaran A, Predeeprompan P, Kongtharvonskul J. Keorochana G, et al. World Neurosurg. 2017 Jun;102:340-349. doi: 10.1016/j.wneu.2017.03.010. Epub 2017 Mar 16. World Neurosurg. 2017. PMID: 28315800 Review.
PURPOSE: We conducted a systematic review and meta-analysis to compare the postoperative outcomes of cortical screw and pedicle screw (PS) fixation techniques for posterior lumbar interbody fusion (PLIF). METHOD: We searched all comparative studies that compared pos …
PURPOSE: We conducted a systematic review and meta-analysis to compare the postoperative outcomes of cortical screw and pedicle sc
446 results
You have reached the last page of results. A maximum of 10,000 results are available.
Jump to page
Feedback