Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1997 1
2000 2
2003 1
2006 1
2009 1
2010 1
2011 1
2016 1
2019 1
2023 1
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

11 results

Results by year

Filters applied: . Clear all
Page 1
Molecular detection of Trichomonas vaginalis from vaginal swabs collected in Copan Transystem(TM) M40 Amies media using the Hologic Panther test system.
Serbanescu MA, Limayo J, Parks A, Goneau LW. Serbanescu MA, et al. Diagn Microbiol Infect Dis. 2024 Feb;108(2):116140. doi: 10.1016/j.diagmicrobio.2023.116140. Epub 2023 Nov 17. Diagn Microbiol Infect Dis. 2024. PMID: 38007913
We evaluated the performance of the Copan Transystem M40 collection swab containing Amies agar gel ('M40') on the Aptima TV Assay for the detection of Trichomonas vaginalis ribosomal RNA (rRNA) using a novel 'Single Swab' molecular workflow. ...
We evaluated the performance of the Copan Transystem M40 collection swab containing Amies agar gel ('M40') on the Aptima TV Assay for …
Evaluation of a novel specimen transport system (Venturi Transystem) for anaerobic bacteria.
Hudspeth MK, Citron DM, Goldstein EJ. Hudspeth MK, et al. Clin Infect Dis. 1997 Sep;25 Suppl 2:S132-3. doi: 10.1086/516198. Clin Infect Dis. 1997. PMID: 9310652
The Venturi Transystem (Copan Diagnostics, Corona, CA), with and without charcoal, is designed for transport of clinical specimens. ...
The Venturi Transystem (Copan Diagnostics, Corona, CA), with and without charcoal, is designed for transport of clinical specimens. . …
Survival of aerobic and anaerobic bacteria in purulent clinical specimens maintained in the Copan Venturi Transystem and Becton Dickinson Port-a-Cul transport systems.
Citron DM, Warren YA, Hudspeth MK, Goldstein EJ. Citron DM, et al. J Clin Microbiol. 2000 Feb;38(2):892-4. doi: 10.1128/JCM.38.2.892-894.2000. J Clin Microbiol. 2000. PMID: 10655410 Free PMC article.
Recovery of aerobic and anaerobic bacteria from clinical specimens maintained in the Copan Venturi Transystem and the Becton Dickinson Port-a-Cul transport was assessed. Of 54 anaerobes, 53 were recovered after 4 h, and 52 were recovered after 24 h, from both systems. ...
Recovery of aerobic and anaerobic bacteria from clinical specimens maintained in the Copan Venturi Transystem and the Becton Dickinso …
Comparison of the eSwab collection and transportation system to an amies gel transystem for Gram stain of clinical specimens.
Fontana C, Favaro M, Limongi D, Pivonkova J, Favalli C. Fontana C, et al. BMC Res Notes. 2009 Dec 10;2:244. doi: 10.1186/1756-0500-2-244. BMC Res Notes. 2009. PMID: 20003247 Free PMC article.
Two swabs were in random order collected from each patient, one using the conventional Amies gel Transystem, the other using ESwab. One slide was prepared for each specimen using the conventional swab and two sets of slides were prepared from the specimens collected with t …
Two swabs were in random order collected from each patient, one using the conventional Amies gel Transystem, the other using ESwab. O …
Prevalence of microbial contamination in donor corneas.
Chen NN, Wu PL, Chen HC, Huang TY, Lai LJ. Chen NN, et al. Taiwan J Ophthalmol. 2019 Sep 12;9(3):179-184. doi: 10.4103/tjo.tjo_60_18. eCollection 2019 Jul-Sep. Taiwan J Ophthalmol. 2019. PMID: 31572655 Free PMC article.
Corneoscleral rim cultures were performed using aerobic/anaerobic culture cotton swabs (Transystem, COPAN, Italia) with subsequent convention media and blood culture media (FAN bottle, BD BACTEC, USA). ...
Corneoscleral rim cultures were performed using aerobic/anaerobic culture cotton swabs (Transystem, COPAN, Italia) with subsequent co …
Comparison of Copan eSwab with the Copan Venturi Transystem for the quantitative survival of Escherichia coli, Streptococcus agalactiae and Candida albicans.
Nys S, Vijgen S, Magerman K, Cartuyvels R. Nys S, et al. Eur J Clin Microbiol Infect Dis. 2010 Apr;29(4):453-6. doi: 10.1007/s10096-010-0883-5. Epub 2010 Mar 4. Eur J Clin Microbiol Infect Dis. 2010. PMID: 20204445
In vitro, the recovery of the three micro-organisms was higher in eSwab (97-100%) as compared to the Copan Venturi Transystem (CVT) (86-96%) at room temperature (RT) for time point 0 h and remained similar after 6 h. ...
In vitro, the recovery of the three micro-organisms was higher in eSwab (97-100%) as compared to the Copan Venturi Transystem (CVT) ( …
Evaluation of four commercial transport media for the survival of Neisseria gonorrhoeae.
Arbique JC, Forward KR, LeBlanc J. Arbique JC, et al. Diagn Microbiol Infect Dis. 2000 Mar;36(3):163-8. doi: 10.1016/s0732-8893(99)00134-0. Diagn Microbiol Infect Dis. 2000. PMID: 10729658
After the 24-hour holding period, 94% of the cultures from the Venturi Transystem were positive, 82% from the Cultureswab, 24% from the Starswab; and 17% from the Culturette EZ. ...Of the swabs tested, Cultureswab and Venturi Transystem were most acceptable....
After the 24-hour holding period, 94% of the cultures from the Venturi Transystem were positive, 82% from the Cultureswab, 24% from t …
Evaluation of three swab transport systems for the maintenance of clinically important bacteria in simulated mono- and polymicrobial samples.
Tano E, Melhus A. Tano E, et al. APMIS. 2011 Mar;119(3):198-203. doi: 10.1111/j.1600-0463.2010.02710.x. APMIS. 2011. PMID: 21284737
In this study, three swab transport systems were evaluated: M40 Transystem, Amies broth with a relatively new type of swab (both Copan Diagnostics, Corona, CA, USA), and SSI transportmedium (Statens Serum Institut, Copenhagen Denmark). ...
In this study, three swab transport systems were evaluated: M40 Transystem, Amies broth with a relatively new type of swab (both Copa …
Methicillin-resistant Staphylococcus aureus in the environment of public transport: data from the metropolitan network in Lyon, France.
Gaymard A, Pichon M, Degaud M, Tasse J, Dupieux C, Laurent F. Gaymard A, et al. Int J Antimicrob Agents. 2016 Oct;48(4):459-62. doi: 10.1016/j.ijantimicag.2016.07.012. Epub 2016 Aug 17. Int J Antimicrob Agents. 2016. PMID: 27575729
Hand-touched surfaces were sampled with sterile swabs (Transystem()) during a 1-day transversal study by collecting 50 samples in seven hub stations and two trains for each of the four Metro lines. ...
Hand-touched surfaces were sampled with sterile swabs (Transystem()) during a 1-day transversal study by collecting 50 samples in sev …
Evaluation of 4 swab transport systems for the recovery of ATCC and clinical strains with characterized resistance mechanisms.
Morosini MI, Loza E, Gutiérrez O, Almaraz F, Baquero F, Cantón R. Morosini MI, et al. Diagn Microbiol Infect Dis. 2006 Sep;56(1):19-24. doi: 10.1016/j.diagmicrobio.2006.02.011. Epub 2006 Jul 5. Diagn Microbiol Infect Dis. 2006. PMID: 16822635
We evaluated the performance of 4 commercial STS: M40 Transystem (S1, Copan Italia, Bovezzo, Italy), UNI-TER (S2, MEUS, Piove di Sacco, Italy), Euromed (S3, LAB SERVICE, Surbo, Italy), and Eurotubo (S4, Deltalab, Rubi, Spain). ...
We evaluated the performance of 4 commercial STS: M40 Transystem (S1, Copan Italia, Bovezzo, Italy), UNI-TER (S2, MEUS, Piove di Sacc …
11 results