Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Edit custom filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2006 1
2012 1
2013 2
2014 1
2016 2
2018 1
2019 3
2020 1
2021 5
2022 4
2023 1
2024 3
2025 7
2026 4

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

31 results

Results by year

Filters applied: . Clear all
Page 1
Clinical performance of monolithic CAD/CAM tooth-supported zirconia restorations: systematic review and meta-analysis.
Leitão CIMB, Fernandes GVO, Azevedo LPP, Araújo FM, Donato H, Correia ARM. Leitão CIMB, et al. J Prosthodont Res. 2022 Jul 30;66(3):374-384. doi: 10.2186/jpr.JPR_D_21_00081. Epub 2021 Oct 6. J Prosthodont Res. 2022. PMID: 34615842 Free article.
PURPOSE: The purpose of this systematic review was to evaluate the survival rate, biological complications, technical complications, and clinical behavior of single crowns supported by teeth made up in monolithic zirconia with CAD/CAM technology. STUDY SELECTION: An …
PURPOSE: The purpose of this systematic review was to evaluate the survival rate, biological complications, technical complications, and cli …
Zirconia in fixed prosthodontics: a review of the literature.
Miura S, Fujita T, Fujisawa M. Miura S, et al. Odontology. 2025 Apr;113(2):466-487. doi: 10.1007/s10266-024-01019-8. Epub 2024 Nov 7. Odontology. 2025. PMID: 39508978 Review.
From PubMed and manual searches, found "zirconia," "crown," "survival," and "success" keywords were searched. Case reports, case series, reviews, abstracts, in vitro studies, and observational studies were excluded. ...However, complications of monolithic zirconi
From PubMed and manual searches, found "zirconia," "crown," "survival," and "success" keywords were searched. Case reports, ca …
Assessing the Longevity of Zirconia-Based Crowns in Bruxism Patients.
Gubrellay P, Almudarris BA, Kumari S, Jamadar NN, Alzahrani KM, Alyazaji AH, Helal DAA. Gubrellay P, et al. J Pharm Bioallied Sci. 2025 Jun;17(Suppl 2):S1162-S1164. doi: 10.4103/jpbs.jpbs_1531_24. Epub 2025 Jun 18. J Pharm Bioallied Sci. 2025. PMID: 40655606 Free PMC article.
MATERIALS AND METHODS: A total of 80 patients (ages 25-60) with diagnosed bruxism were selected for the study. Each patient received at least one zirconia-based crown. ...Patients were divided into two groups: Group A (40 patients) received zirconia
MATERIALS AND METHODS: A total of 80 patients (ages 25-60) with diagnosed bruxism were selected for the study. Each patient received …
FEA Comparison of the Mechanical Behavior of Three Dental Crown Materials: Enamel, Ceramic, and Zirconia.
Ceddia M, Lamberti L, Trentadue B. Ceddia M, et al. Materials (Basel). 2024 Jan 30;17(3):673. doi: 10.3390/ma17030673. Materials (Basel). 2024. PMID: 38591528 Free PMC article.
In the case of the zirconia crown, the stresses are much higher than those in the ceramic crown, except for the 45 load direction, while, for the horizontal loads, the stress peak in the zirconia crown is almost three times as large as its coun …
In the case of the zirconia crown, the stresses are much higher than those in the ceramic crown, except for the 45 loa …
Bruxism and direct and indirect restorations failure: A scoping review.
Al-Talib T, Goodman X, Ziada H, Abubakr NH. Al-Talib T, et al. J Dent. 2025 Jun;157:105738. doi: 10.1016/j.jdent.2025.105738. Epub 2025 Apr 6. J Dent. 2025. PMID: 40199416
The studies were on the relationship between bruxism and restorations failure: dental implants studies were 58.7 %; mixed restorations were 10.9 %; indirect restoration (Full Coverage Crowns and Fixed Partial Dentures) 15.2 %; indirect partial coverage restoration ( …
The studies were on the relationship between bruxism and restorations failure: dental implants studies were 58.7 %; mixed restoration …
Evaluating the durability of zirconia - based crowns among patients with bruxism.
Sharma S, Sahoo PK, Mohanty AK, Soni P, Arya A, Soni B. Sharma S, et al. Bioinformation. 2025 Aug 31;21(8):2500-2503. doi: 10.6026/973206300212500. eCollection 2025. Bioinformation. 2025. PMID: 41393403 Free PMC article.
The clinical durability of zirconia-based crowns in patients with bruxism over a 12-24 month period is of interest. Patients received zirconia crowns and were assessed for crown fracture, veneering chipping, marginal adaptation, wear and …
The clinical durability of zirconia-based crowns in patients with bruxism over a 12-24 month period is of interest. Pat …
Fracture Resistance of Monolithic Zirconia Crowns in Implant Prostheses in Patients with Bruxism.
Lan TH, Pan CY, Liu PH, Chou MMC. Lan TH, et al. Materials (Basel). 2019 May 17;12(10):1623. doi: 10.3390/ma12101623. Materials (Basel). 2019. PMID: 31108872 Free PMC article.
The aim of this study is to determine the minimum required thickness of a monolithic zirconia crown in the mandibular posterior area for patients with bruxism. Forty-nine full zirconia crowns, with seven different occlusal thicknesses of 0.4, 0. …
The aim of this study is to determine the minimum required thickness of a monolithic zirconia crown in the mandibular posterio …
Ceramic crowns and sleep bruxism: 3-year results of a randomized controlled trial.
Bömicke W, Schmitter M, Waldecker M, Handermann R, Labis C, Rammelsberg P, Ohlmann B. Bömicke W, et al. J Dent. 2026 Jul;170:106691. doi: 10.1016/j.jdent.2026.106691. Epub 2026 Apr 10. J Dent. 2026. PMID: 41967567 Free article. Clinical Trial.
OBJECTIVE: To evaluate whether sleep bruxism (SB) influences the occurrence of technical complications and affects the survival and success of monolithic lithium disilicate (LiDi) or zirconia (Zir) molar crowns over 3 years. ...CONCLUSION: Within a 3-year obs …
OBJECTIVE: To evaluate whether sleep bruxism (SB) influences the occurrence of technical complications and affects the survival and s …
Clinical behavior of second-generation zirconia monolithic posterior restorations: Two-year results of a prospective study with Ex vivo analyses including patients with clinical signs of bruxism.
Koenig V, Wulfman C, Bekaert S, Dupont N, Le Goff S, Eldafrawy M, Vanheusden A, Mainjot A. Koenig V, et al. J Dent. 2019 Dec;91:103229. doi: 10.1016/j.jdent.2019.103229. Epub 2019 Nov 10. J Dent. 2019. PMID: 31722238 Free article.
OBJECTIVES: This study aimed to investigate (1) clinical outcomes of second-generation zirconia restorations, including patients with bruxism clinical signs, and (2) the material wear process. ...CONCLUSIONS: Monolithic zirconia FPDs are promising but the fai …
OBJECTIVES: This study aimed to investigate (1) clinical outcomes of second-generation zirconia restorations, including patients with …
Three-dimensional finite element analysis of implant-supported prosthodontic designs for maxillary first molars with root fracture.
An Z, Qi Y, Hong W, Luo S, Liao J. An Z, et al. BMC Oral Health. 2025 Sep 26;25(1):1470. doi: 10.1186/s12903-025-06848-9. BMC Oral Health. 2025. PMID: 41013484 Free PMC article.
Three zirconia/resin implant crowns with cusp inclinations were modeled on the fracture geometry. ...In implant-supported prostheses, increased cusp inclination elevated stress in both implants and peri-implant bone, with zirconia crowns exhibiting hig …
Three zirconia/resin implant crowns with cusp inclinations were modeled on the fracture geometry. ...In implant-supported pros …
31 results