Postbiopsy bleeding in a porcine model: reduction with radio-frequency ablation--preliminary results

Radiology. 2003 May;227(2):493-9. doi: 10.1148/radiol.2272020173. Epub 2003 Apr 3.

Abstract

Purpose: To test a biopsy needle modified for use of radio-frequency (RF) energy to produce hemostasis after core biopsy of liver or kidney.

Materials and methods: RF energy was applied to a partially insulated 17-gauge needle, and tip temperature was monitored with a thermocouple. Domestic Yorkshire pigs (n = 4; mean weight, 23.4 kg) were anesthetized, and their livers and kidneys were exposed. Needles were inserted 2 cm into hepatic and renal parenchyma and retracted, either with or without tract ablation to 65 degrees C, in normal tissue, animals treated with anticoagulants, and an animal with acute inferior vena caval occlusion to produce portal hypertension. Blood loss was assessed by weighing surgical sponges with blood from the puncture sites. Significant differences in blood loss between control and ablated biopsy specimens in each scenario were tested by using a Wilcoxon matched-pairs signed rank test.

Results: Mean blood loss for each group was as follows: In the liver, control biopsy specimens (n = 18) lost 0.30 g while ablated biopsy specimens lost 0.00044 g (P <.01), and control biopsy specimens treated with heparin (n = 26) lost 0.45 g while biopsy specimens treated with heparin and ablation lost 0.27 g (P =.03). For inferior vena caval occlusion, control biopsy specimens lost 1.23 g, while ablated biopsy specimens lost 0.00 g. In the kidney, control biopsy specimens (n = 28) lost 0.82 g, while ablated biopsy specimens lost 0.24 g (P =.01), and control biopsy specimens treated with heparin (n = 14) lost 1.04 g, while biopsy specimens treated with heparin and ablation lost 0.19 g (P =.02).

Conclusion: Tract ablation with thermocouple-monitored RF energy decreased postprocedural hemorrhage after hepatic and renal biopsy.

MeSH terms

  • Animals
  • Biopsy, Needle / adverse effects*
  • Catheter Ablation / adverse effects*
  • Disease Models, Animal*
  • Female
  • Hemostatic Techniques*
  • Postoperative Hemorrhage / prevention & control*
  • Swine